H1 Regulator OUPSO Direct Acting First Stage GN-GLP 1400mbar 1 "NPThx1 "NPTh
H1 Regulator OUPSO Direct Acting First Stage GN-GLP 1400mbar 1 "NPThx1 "NPTh
Regulator for external use for medium-sized commercial installations and in gas industry. Reference standard EN334 and under the guidelines 2014/68/EU. With different flow rates according to the application and safety device.
Regulator for external use for medium-sized commercial installations and in gas industry. Reference standard EN334 and under the guidelines 2014/68/EU. With different flow rates according to the application and safety device.
External use regulator for residential and commercial gas installations. Reference Standard MX-032-X-SCFI-2013 and specification ES.02260.MX-CN. With different flow rates according to the application and safety device relief valve and low pressure cut-off (UPSO).
Regulator for internal use for residential gas installations. Reference Standard NTC-3293. With different flow rates according to the application and safety device Proportional Shut-Off and Low Pressure Cut-Off at the inlet.
Regulator for external use for residential gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
Regulator for external use for residential and commercial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
Regulator for external use for residential installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
Content
Inlet pressure min. 2.06 bar (30 psi). Max. inlet pressure 6.89 bar (100 psi). Outlet pressure 1400 mbar (560 "c.a.). Inlet connection 1" NPT h Outlet connection 1" NPT h.
Inlet Pressure MIN. 1 bar (14.5 psi). Inlet Pressure MAX. 4 bar (58 psi). Outlet Pressure 21 mbar (8.4 "w.c.). Flow rate at inlet pressure
inlet pressure MIN Flow Kg/h LPG: 0. with set pressure m³/ h GN 10. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT h
Inlet Pressure MIN. bar (1.5 psi). Inlet Pressure MAX. bar (9.9 psi). Outlet Pressure 35 mbar (14 "w.c.). Flow rate at inlet pressure
inlet pressure MIN. m³/ h GN 12. with set pressure m³/ h GN 23. Inlet connection 1/2" NPT h Outlet connection 1/2" NPT h
Min. inlet pressure 0.2 bar (2.9 psi). Max. inlet pressure 1.4 bar (20.3 psi). Outlet pressure 28 mbar (11,2 "c.a.). Flow rate at min. inlet pressure 8.9 kg/h LPG (445,000 BTU/h LPG). Flow rate at set pressure 13.7Kg/h LPG (685,300 BTU/h LPG). Inlet connection 3/4" NPT h Outlet connection 3/4" NPT h
Inlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 6.9 bar (100 psi). Outlet Pressure 15 psi (1034 mbar). Flow rate with inlet pressure MIN Flow rate 33.9 Kg/h LPG, with set pressure Flow rate 105.7 Kg/h LPG. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT h.
Inlet Pressure MIN. 1.04 bar (15.1 psi). MAX Inlet Pressure. 6.9 bar (100 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate at inlet pressure MIN Flow rate 15.4Kg/h LPG, at set pressure Flow rate 22.1Kg/h LPG. Connection Inlet 1" NPT h Connection Outlet 1" NPT h
Additional Information
Brand
ESKA
Connection Input
1" NPT h
Connection Output
1" NPT h
Type of Adjustment
Not Adjustable
Stage
First Stage
Security System
Low and high pressure cut-off at inlet
Maximum inlet pressure
100 psi
Minimum inlet pressure
30 psi
Outlet pressure
1400 mbar
Nominal flow rate
AC 10: 52 m³/ h GN, AC 10: 60 kg/h LPG
Brand
Humcar
Connection Input
3/4" NPT h
Connection Output
3/4" NPT h
Type of Adjustment
Not Adjustable
Stage
Single Stage
Security System
Relief Valve.
Maximum inlet pressure
58
Minimum inlet pressure
14.5
Outlet pressure
21 mbar
Nominal flow rate
10 m³/ h GN
Brand
Humcar
Connection Input
1/2" NPT h
Connection Output
1/2" NPT h
Type of Adjustment
Not Adjustable
Stage
Second Stage
Security System
Proportional shut-off and low pressure cut-off at the inlet.
Regulator for external use for residential and commercial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
Regulator for external use for residential installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
Regulator for external use for residential and industrial gas installations. Reference Standard With different flow rates according to the application and safety device.
Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.