• Home
  • Products
  • Regulator OPSO Direct Acting First Stage GN 250 mbar 3/4" NPT h x 3/4" NPT h 15 m³/ h GN

Regulator OPSO Direct Acting First Stage GN 250 mbar 3/4" NPT h x 3/4" NPT h 15 m³/ h GN

Regulator for internal use for residential and commercial gas installations. Reference standard ES.02260.MX-CN and standard MX-032-x-SCFI-2013. With different flow rates according to the application and overpressure cut-off safety device.

Description

Inlet Pressure MIN. 1 bar (14.5 psi). Inlet Pressure MAX. 4 bar (58 psi). Outlet Pressure 250 mbar ("c.a.). Flow rate at inlet pressure
inlet pressure MIN Flow rate Kg/h LPG: 0. with set pressure m³/ h GN 15. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT h

Additional information

Brand

Humcar

Connection Input

3/4" NPT h

Connection Output

3/4" NPT h

Type of Adjustment

Not Adjustable

Stage

First Stage

Security System

Overpressure cutting.

Maximum inlet pressure

58

Minimum inlet pressure

14.5

Outlet pressure

250 mbar

Nominal flow rate

15 m³/ h GN

Documents

Quick comparison

Regulator OPSO Direct Acting First Stage GN 250 mbar 3/4" NPT h x 3/4" NPT h 15 m³/ h GN RemoveHigh Pressure Regulator Direct Acting First Stage LPG 10 - 30 psi 1/2" NPT h x 1/2" NPT h 3365482 BTU/h LPG RemoveRegulator R4 Direct Acting Single Stage LPG 28 mbar M26 X 1.5 x 1/2" NPT h 360450 BTU/h LPG RemoveLow Pressure Cut-Off Regulator RCBP Self-Compensating Second Stage GN 35 mbar 1/2" NPT h x 1/2" NPT h 12 m³/ h GN RemoveRegulator R50 Direct Acting Second Stage GN 100 mbar 1 NPT h x 1 NPT h 23 m³/ h GN RemoveRegulator R10 Adjustable Direct Acting First Stage LPG 0.5 - 12.4 psi 3/4" NPT h x 3/4" NPT h 215736 BTU/h LPG Remove
NameRegulator OPSO Direct Acting First Stage GN 250 mbar 3/4" NPT h x 3/4" NPT h 15 m³/ h GN RemoveHigh Pressure Regulator Direct Acting First Stage LPG 10 - 30 psi 1/2" NPT h x 1/2" NPT h 3365482 BTU/h LPG RemoveRegulator R4 Direct Acting Single Stage LPG 28 mbar M26 X 1.5 x 1/2" NPT h 360450 BTU/h LPG RemoveLow Pressure Cut-Off Regulator RCBP Self-Compensating Second Stage GN 35 mbar 1/2" NPT h x 1/2" NPT h 12 m³/ h GN RemoveRegulator R50 Direct Acting Second Stage GN 100 mbar 1 NPT h x 1 NPT h 23 m³/ h GN RemoveRegulator R10 Adjustable Direct Acting First Stage LPG 0.5 - 12.4 psi 3/4" NPT h x 3/4" NPT h 215736 BTU/h LPG Remove
ImageRegulator OPSO Direct Acting First Stage GN 250 mbar 3/4" NPT h x 3/4" NPT h 15 m³/ h GNHigh Pressure Regulator Direct Acting First Stage LPG 10 - 30 psi 1/2" NPT h x 1/2" NPT h 3365482 BTU/h LPGRegulator R4 Direct Acting Single Stage LPG 28 mbar M26 X 1.5 x 1/2" NPT h 360450 BTU/h LPGLow Pressure Cut-Off Regulator RCBP Self-Compensating Second Stage GN 35 mbar 1/2" NPT h x 1/2" NPT h 12 m³/ h GNRegulator R50 Direct Acting Second Stage GN 100 mbar 1 NPT h x 1 NPT h 23 m³/ h GNRegulator R10 Adjustable Direct Acting First Stage LPG 0.5 - 12.4 psi 3/4" NPT h x 3/4" NPT h 215736 BTU/h LPG
Reference411723410200410818411504414018411255
Rating
Stock
Availability
Add to cart

Read more

Read more

Read more

Read more

Read more

Read more

DescriptionRegulator for internal use for residential and commercial gas installations. Reference standard ES.02260.MX-CN and standard MX-032-x-SCFI-2013. With different flow rates according to the application and overpressure cut-off safety device. External use regulator for commercial and industrial gas installations. Reference Standard NFPA-58 and NTC-3873. With different flow rates according to the application and safety device.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for internal use for residential gas installations. Reference Standard NTC-3293. With different flow rates according to the application and safety device Proportional Shut-Off and Low Pressure Cut-Off at the inlet.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3727. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential and industrial gas installations. Reference Standard With different flow rates according to the application and safety device.
ContentInlet Pressure MIN. 1 bar (14.5 psi). MAX Inlet Pressure. 4 bar (58 psi). Outlet Pressure 250 mbar ("c.a.). Flow rate at inlet pressure inlet pressure MIN Flow rate Kg/h LPG: 0. with set pressure m³/ h GN 15. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT hInlet Pressure Min. 2 bar (29 psi). Max. Inlet Pressure 100 psi (6.9 bar). Output Pressure 10 - 30 psi. Flow rate at inlet pressure Max. 3.365.482 BTU/h LPG. Inlet connection 1/2" NPT h Outlet connection 1/2" NPT h.Inlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 5.5 bar (79.8 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate with inlet pressure MIN Flow rate 7.2Kg/h LPG, with set pressure Flow rate 10.3Kg/h LPG. Inlet connection M26 X 1,5 Outlet connection 1/2" NPT h.Inlet Pressure MIN. bar (1.5 psi). Inlet Pressure MAX. bar (9.9 psi). Outlet Pressure 35 mbar (14 "w.c.). Flow rate at inlet pressure inlet pressure MIN. m³/ h GN 12. with set pressure m³/ h GN 23. Inlet connection 1/2" NPT h Outlet connection 1/2" NPT hInlet Pressure MIN. 0.21 bar (3 psi). MAX Inlet Pressure 0.48 bar (7 psi). Outlet Pressure 100 mbar (40 "a.c.). Flow rate at inlet pressure inlet pressure MIN. m³/ h GN 23. with set pressure m³/ h GN 35. Inlet connection 1 NPT h Outlet connection 1 NPT hInlet Pressure MIN. 1 bar (14.5 psi). Inlet Pressure MAX. 4.2 bar (60.9 psi). Outlet Pressure mbar ("c.a.). Flow rate at inlet pressure inlet pressure MIN Flow rate Kg/h LPG: 0. with set pressure Flow rate Kg/h LPG: . Inlet connection 3/4" NPT h Outlet connection 3/4" NPT h
Additional Information
Brand

Humcar

Connection Input

3/4" NPT h

Connection Output

3/4" NPT h

Type of Adjustment

Not Adjustable

Stage

First Stage

Security System

Overpressure cutting.

Maximum inlet pressure

58

Minimum inlet pressure

14.5

Outlet pressure

250 mbar

Nominal flow rate

15 m³/ h GN

Brand

Humcar

Connection Input

1/2" NPT h

Connection Output

1/2" NPT h

Type of Adjustment

Adjustable

Stage

First Stage

Security System

Not applicable.

Maximum inlet pressure

100 psi

Minimum inlet pressure

29 psi

Outlet pressure

10 - 30 psi

Nominal flow rate

3365482 BTU/h LPG

Brand

Humcar

Connection Input

5, M26 X 1

Connection Output

1/2" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

79.8

Minimum inlet pressure

20.3

Outlet pressure

28 mbar

Nominal flow rate

360450 BTU/h LPG

Brand

Humcar

Connection Input

1/2" NPT h

Connection Output

1/2" NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Proportional shut-off and low pressure cut-off at the inlet.

Maximum inlet pressure

9.9

Minimum inlet pressure

1.5

Outlet pressure

35 mbar

Nominal flow rate

12 m³/ h GN

Brand

Humcar

Connection Input

1 NPT h

Connection Output

1 NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Relief Valve.

Maximum inlet pressure

7

Minimum inlet pressure

3

Outlet pressure

100 mbar

Nominal flow rate

23 m³/ h GN

Brand

Humcar

Connection Input

3/4" NPT h

Connection Output

3/4" NPT h

Type of Adjustment

Adjustable

Stage

First Stage

Security System

Not applicable.

Maximum inlet pressure

60.9

Minimum inlet pressure

14.5

Outlet pressure

0.5 - 12.4 psi

Nominal flow rate

215736 BTU/h LPG

Cart
No products in the cart.
Notificaciones Judiciales
Email
WhatsApp
Phone
WhatsApp
Phone
Email
Notificaciones Judiciales
Select the fields to display
  • Image
  • Reference
  • Rating
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Additional Information
Click outside the comparison bar to close it.
Compare