• Home
  • Products
  • Regulador R10 RVI Acción Directa Única Etapa GN 18 mbar 1” NPT h x 1” NPT h 15 m³/ h GN

Regulator R10 RVI Direct Acting Single Stage GN 18 mbar 1" NPT h x 1" NPT h 15 m³/ h GN

Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3727. With different flow rates according to the application and safety device relief valve.

Description

Presión de Entrada MIN. 1.4 bar (20.3 psi). Presión de Entrada MÁX. 4 bar (58 psi). Presión de Salida 18 mbar (7.2 “c.a.). Caudal con presión
de entrada MÍN m³/ h GN 15. con presión de ajuste m³/ h GN 15. Conexión Entrada 1” NPT h Conexión Salida 1” NPT h

Additional information

Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

58

Minimum inlet pressure

20.3

Outlet pressure

18 mbar

Nominal flow rate

15 m³/ h GN

Documents

Quick comparison

Regulador R10 RVI Acción Directa Única Etapa GN 18 mbar 1” NPT h x 1” NPT h 15 m³/ h GN RemoverRegulator R10 Direct Acting First Stage LPG 15 psi 3/4" NPT h x 3/4" NPT h 1691000 BTU/h LPG RemoveRegulator R101 Direct Acting Single Stage LPG 28 mbar M11 X 1 x 3/8" NPT h 72090 BTU/h LPG RemoveLow Pressure Cut-Off Regulator RCBP Self-Compensating Second Stage GN 35 mbar 1/2" NPT h x 1/2" NPT h 12 m³/ h GN RemoveRegulator R50 Direct Acting Second Stage GN 100 mbar 1 NPT h x 1 NPT h 23 m³/ h GN RemoveRegulator R50 Direct Acting Single Stage LPG 28 mbar 1-1/4" NPT h x 1-1/4" NPT h 1379500 BTU/h LPG Remove
NameRegulador R10 RVI Acción Directa Única Etapa GN 18 mbar 1” NPT h x 1” NPT h 15 m³/ h GN RemoverRegulator R10 Direct Acting First Stage LPG 15 psi 3/4" NPT h x 3/4" NPT h 1691000 BTU/h LPG RemoveRegulator R101 Direct Acting Single Stage LPG 28 mbar M11 X 1 x 3/8" NPT h 72090 BTU/h LPG RemoveLow Pressure Cut-Off Regulator RCBP Self-Compensating Second Stage GN 35 mbar 1/2" NPT h x 1/2" NPT h 12 m³/ h GN RemoveRegulator R50 Direct Acting Second Stage GN 100 mbar 1 NPT h x 1 NPT h 23 m³/ h GN RemoveRegulator R50 Direct Acting Single Stage LPG 28 mbar 1-1/4" NPT h x 1-1/4" NPT h 1379500 BTU/h LPG Remove
ImageRegulator R10 RVI Direct Acting Single Stage GN 18 mbar 1" NPT h x 1" NPT h 15 m³/ h GNRegulator R10 Direct Acting First Stage LPG 15 psi 3/4" NPT h x 3/4" NPT h 1691000 BTU/h LPGRegulator R101 Direct Acting Single Stage LPG 28 mbar M11 X 1 x 3/8" NPT h 72090 BTU/h LPGLow Pressure Cut-Off Regulator RCBP Self-Compensating Second Stage GN 35 mbar 1/2" NPT h x 1/2" NPT h 12 m³/ h GNRegulator R50 Direct Acting Second Stage GN 100 mbar 1 NPT h x 1 NPT h 23 m³/ h GNRegulator R50 Direct Acting Single Stage LPG 28 mbar 1-1/4" NPT h x 1-1/4" NPT h 1379500 BTU/h LPG
Reference411244411261410880411504414018414002
Rating
Stock
Availability
Add to cart

Read more

Read more

Read more

Read more

Read more

Read more

DescriptionRegulator for external use for residential and industrial gas installations. Reference Standard NTC-3727. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential and commercial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for internal use for residential gas installations. Reference Standard NTC-3293. With different flow rates according to the application and safety device Proportional Shut-Off and Low Pressure Cut-Off at the inlet.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3727. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
ContentPresión de Entrada MIN. 1.4 bar (20.3 psi). Presión de Entrada MÁX. 4 bar (58 psi). Presión de Salida 18 mbar (7.2 "c.a.). Caudal con presión de entrada MÍN m³/ h GN 15. con presión de ajuste m³/ h GN 15. Conexión Entrada 1” NPT h Conexión Salida 1” NPT hInlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 6.9 bar (100 psi). Outlet Pressure 15 psi (1034 mbar). Flow rate with inlet pressure MIN Flow rate 33.9 Kg/h LPG, with set pressure Flow rate 105.7 Kg/h LPG. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT h.Inlet Pressure MIN. 0.7 bar (10.2 psi). MAX Inlet Pressure. 7 bar (100 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate with inlet pressure MIN Flow rate 1.4Kg/h LPG, with set pressure Flow rate 2.6Kg/h LPG. Connection Inlet M11 X 1 Connection Outlet 3/8" NPT hInlet Pressure MIN. bar (1.5 psi). Inlet Pressure MAX. bar (9.9 psi). Outlet Pressure 35 mbar (14 "w.c.). Flow rate at inlet pressure inlet pressure MIN. m³/ h GN 12. with set pressure m³/ h GN 23. Inlet connection 1/2" NPT h Outlet connection 1/2" NPT hInlet Pressure MIN. 0.21 bar (3 psi). MAX Inlet Pressure 0.48 bar (7 psi). Outlet Pressure 100 mbar (40 "a.c.). Flow rate at inlet pressure inlet pressure MIN. m³/ h GN 23. with set pressure m³/ h GN 35. Inlet connection 1 NPT h Outlet connection 1 NPT hInlet Pressure MIN. 0.7 bar (10.2 psi). MAX Inlet Pressure. 5.52 bar (80 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate with inlet pressure MIN 27.6Kg/h LPG, with set pressure Flow rate 84.8Kg/h LPG. Connection Inlet 1-1/4" NPT h Connection Outlet 1-1/4" NPT h.
Additional Information
Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

58

Minimum inlet pressure

20.3

Outlet pressure

18 mbar

Nominal flow rate

15 m³/ h GN

Brand

Humcar

Connection Input

3/4" NPT h

Connection Output

3/4" NPT h

Type of Adjustment

Not Adjustable

Stage

First Stage

Security System

Relief Valve.

Maximum inlet pressure

100

Minimum inlet pressure

20.3

Outlet pressure

15 psi

Nominal flow rate

1691000 BTU/h LPG

Brand

Humcar

Connection Input

M11 X 1

Connection Output

3/8" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

100

Minimum inlet pressure

10.2

Outlet pressure

28 mbar

Nominal flow rate

72090 BTU/h LPG

Brand

Humcar

Connection Input

1/2" NPT h

Connection Output

1/2" NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Proportional shut-off and low pressure cut-off at the inlet.

Maximum inlet pressure

9.9

Minimum inlet pressure

1.5

Outlet pressure

35 mbar

Nominal flow rate

12 m³/ h GN

Brand

Humcar

Connection Input

1 NPT h

Connection Output

1 NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Relief Valve.

Maximum inlet pressure

7

Minimum inlet pressure

3

Outlet pressure

100 mbar

Nominal flow rate

23 m³/ h GN

Brand

Humcar

Connection Input

1-1/4" NPT h

Connection Output

1-1/4" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

80

Minimum inlet pressure

10.2

Outlet pressure

28 mbar

Nominal flow rate

1379500 BTU/h LPG

Cart
No products in the cart.
Notificaciones Judiciales
Email
WhatsApp
Phone
WhatsApp
Phone
Email
Notificaciones Judiciales
Select the fields to display
  • Image
  • Reference
  • Rating
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Additional Information
Click outside the comparison bar to close it.
Compare