• Home
  • Products
  • Regulador R4 Acción Directa Única Etapa GN 18 mbar 1/2” NPT h x 1/2” NPT h 3 m³/ h GN

Regulator R4 Direct Action Single Stage GN 18 mbar 1/2" NPT h x 1/2" NPT h 3 m³/ h GN

External use regulator for residential gas installations. Manufactured under NTC-3727 standard. With different flow rates according to the application and safety device relief valve.

Description

Presión de Entrada Mín. 1,7 bar (24,7 psi). Presión de Entrada Máx. 4 bar (58 psi). Presión de Salida 18 mbar (7,2 “c.a.). Caudal con presión de entrada Mín. 3 m³/ h GN . Con presión de ajuste 5 m³/ h GN. Conexión Entrada 1/2” NPT h Conexión Salida 1/2” NPT h

Additional information

Brand

Humcar

Connection Input

1/2" NPT h

Connection Output

1/2" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

58 psi

Minimum inlet pressure

24.7 psi

Outlet pressure

18 mbar

Max. flow rate

3 m³/ h GN

Nominal flow rate

5 m³/ h GN

Documents

Quick comparison

Regulador R4 Acción Directa Única Etapa GN 18 mbar 1/2” NPT h x 1/2” NPT h 3 m³/ h GN RemoverRegulator R10 Direct Acting Single Stage LPG 28 mbar 3/4" NPT h x 3/4" NPT h 863300 BTU/h LPG RemoveRegulator R4 Direct Acting Single Stage LPG 28 mbar M26 X 1.5 x 1/2" NPT h 360450 BTU/h LPG RemoveLow Pressure Cut-Off Regulator RCBP Self-Compensating Second Stage GN 50 mbar 1/2" NPT h x 1/2" NPT h 20 m³/ h GN RemoveRegulator R50 Direct Acting Second Stage LPG 28 mbar 1" NPT h x 1" NPT h 1619800 BTU/h LPG RemoveHigh Pressure Regulator Direct Acting First Stage LPG 10 - 30 psi 1/2" NPT h x 1/2" NPT h 3365482 BTU/h LPG Remove
NameRegulador R4 Acción Directa Única Etapa GN 18 mbar 1/2” NPT h x 1/2” NPT h 3 m³/ h GN RemoverRegulator R10 Direct Acting Single Stage LPG 28 mbar 3/4" NPT h x 3/4" NPT h 863300 BTU/h LPG RemoveRegulator R4 Direct Acting Single Stage LPG 28 mbar M26 X 1.5 x 1/2" NPT h 360450 BTU/h LPG RemoveLow Pressure Cut-Off Regulator RCBP Self-Compensating Second Stage GN 50 mbar 1/2" NPT h x 1/2" NPT h 20 m³/ h GN RemoveRegulator R50 Direct Acting Second Stage LPG 28 mbar 1" NPT h x 1" NPT h 1619800 BTU/h LPG RemoveHigh Pressure Regulator Direct Acting First Stage LPG 10 - 30 psi 1/2" NPT h x 1/2" NPT h 3365482 BTU/h LPG Remove
ImageRegulator R4 Direct Action Single Stage GN 18 mbar 1/2" NPT h x 1/2" NPT h 3 m³/ h GNRegulator R10 Direct Acting Single Stage LPG 28 mbar 3/4" NPT h x 3/4" NPT h 863300 BTU/h LPGRegulator R4 Direct Acting Single Stage LPG 28 mbar M26 X 1.5 x 1/2" NPT h 360450 BTU/h LPGLow Pressure Cut-Off Regulator RCBP Self-Compensating Second Stage GN 50 mbar 1/2" NPT h x 1/2" NPT h 20 m³/ h GNRegulator R50 Direct Acting Second Stage LPG 28 mbar 1" NPT h x 1" NPT h 1619800 BTU/h LPGHigh Pressure Regulator Direct Acting First Stage LPG 10 - 30 psi 1/2" NPT h x 1/2" NPT h 3365482 BTU/h LPG
Reference410828411267410818411518414003410200
Rating
Stock
Availability
Add to cart

Read more

Read more

Read more

Read more

Read more

Read more

DescriptionExternal use regulator for residential gas installations. Manufactured under NTC-3727 standard. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for internal use for residential gas installations. Reference Standard NTC-3293. With different flow rates according to the application and safety device Proportional Shut-Off and Low Pressure Cut-Off at the inlet.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.External use regulator for commercial and industrial gas installations. Reference Standard NFPA-58 and NTC-3873. With different flow rates according to the application and safety device.
ContentPresión de Entrada Mín. 1,7 bar (24,7 psi). Presión de Entrada Máx. 4 bar (58 psi). Presión de Salida 18 mbar (7,2 "c.a.). Caudal con presión de entrada Mín. 3 m³/ h GN . Con presión de ajuste 5 m³/ h GN. Conexión Entrada 1/2” NPT h Conexión Salida 1/2” NPT hInlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 6.9 bar (100 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate with inlet pressure MIN Flow rate 17.3Kg/h LPG. With set pressure Flow 30 Kg/h LPG. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT hInlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 5.5 bar (79.8 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate with inlet pressure MIN Flow rate 7.2Kg/h LPG, with set pressure Flow rate 10.3Kg/h LPG. Inlet connection M26 X 1,5 Outlet connection 1/2" NPT h.Inlet Pressure MIN. bar (3 psi). Inlet Pressure MAX. bar (10 psi). Outlet Pressure 50 mbar (20 "c.a.). Flow rate at inlet pressure inlet pressure MIN. m³/ h GN 20. with set pressure m³/ h GN 19. Inlet connection 1/2" NPT h Outlet connection 1/2" NPT hInlet Pressure MIN. 0.21 bar (3 psi). MAX Inlet Pressure 2 bar (29 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate at inlet pressure inlet pressure MIN Flow rate Kg/h LPG: 32.5. with set pressure Flow rate Kg/h LPG: 46.4285714285714. Inlet connection 1" NPT h Outlet connection 1" NPT hInlet Pressure Min. 2 bar (29 psi). Max. Inlet Pressure 100 psi (6.9 bar). Output Pressure 10 - 30 psi. Flow rate at inlet pressure Max. 3.365.482 BTU/h LPG. Inlet connection 1/2" NPT h Outlet connection 1/2" NPT h.
Additional Information
Brand

Humcar

Connection Input

1/2" NPT h

Connection Output

1/2" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

58 psi

Minimum inlet pressure

24.7 psi

Outlet pressure

18 mbar

Max. flow rate

3 m³/ h GN

Nominal flow rate

5 m³/ h GN

Brand

Humcar

Connection Input

3/4" NPT h

Connection Output

3/4" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

100

Minimum inlet pressure

20.3

Outlet pressure

28 mbar

Nominal flow rate

863300 BTU/h LPG

Brand

Humcar

Connection Input

5, M26 X 1

Connection Output

1/2" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

79.8

Minimum inlet pressure

20.3

Outlet pressure

28 mbar

Nominal flow rate

360450 BTU/h LPG

Brand

Humcar

Connection Input

1/2" NPT h

Connection Output

1/2" NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Proportional shut-off and low pressure cut-off at the inlet.

Maximum inlet pressure

10

Minimum inlet pressure

3

Outlet pressure

50 mbar

Nominal flow rate

20 m³/ h GN

Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Relief Valve.

Maximum inlet pressure

29

Minimum inlet pressure

3

Outlet pressure

28 mbar

Nominal flow rate

1619800 BTU/h LPG

Brand

Humcar

Connection Input

1/2" NPT h

Connection Output

1/2" NPT h

Type of Adjustment

Adjustable

Stage

First Stage

Security System

Not applicable.

Maximum inlet pressure

100 psi

Minimum inlet pressure

29 psi

Outlet pressure

10 - 30 psi

Nominal flow rate

3365482 BTU/h LPG

Cart
No products in the cart.
Notificaciones Judiciales
Email
WhatsApp
Phone
WhatsApp
Phone
Email
Notificaciones Judiciales
Select the fields to display
  • Image
  • Reference
  • Rating
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Additional Information
Click outside the comparison bar to close it.
Compare