  • Regulator R50 OPSO Direct Acting Second Stage GN 23 mbar 1" NPT h x 1" NPT h 40 m³/h GN

Regulator R50 OPSO Direct Acting Second Stage GN 23 mbar 1" NPT h x 1" NPT h 40 m³/ h GN

Regulator for internal use for residential and industrial gas installations. Reference Standard NTC-3293. With different flow rates according to the application and overpressure cut-off safety device.

Description

Inlet Pressure MIN. 0.28 bar (4.1 psi). MAX Inlet Pressure 2 bar (29 psi). Outlet Pressure 23 mbar (9.2 "w.c.). Flow rate at inlet pressure
inlet pressure MIN m³/ h GN 40. with set pressure m³/ h GN 50. Inlet connection 1" NPT h Outlet connection 1" NPT h

Additional information

Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Overpressure cutting.

Maximum inlet pressure

29

Minimum inlet pressure

4.1

Outlet pressure

23 mbar

Nominal flow rate

40 m³/ h GN

Documents

Quick comparison

Regulator R50 OPSO Direct Acting Second Stage GN 23 mbar 1" NPT h x 1" NPT h 40 m³/ h GN RemoveRegulator R10 RVI Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 768960 BTU/h LPG RemoveRegulator R10 Adjustable Direct Acting First Stage LPG 0.5 - 12.4 psi 3/4" NPT h x 3/4" NPT h 215736 BTU/h LPG RemoveRegulator R10 Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 863300 BTU/h LPG RemoveRegulator R50 Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 1379500 BTU/h LPG RemoveRegulator R4 Direct Acting Single Stage LPG 28 mbar M26 X 1.5 x 1/2" NPT h 360450 BTU/h LPG Remove
NameRegulator R50 OPSO Direct Acting Second Stage GN 23 mbar 1" NPT h x 1" NPT h 40 m³/ h GN RemoveRegulator R10 RVI Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 768960 BTU/h LPG RemoveRegulator R10 Adjustable Direct Acting First Stage LPG 0.5 - 12.4 psi 3/4" NPT h x 3/4" NPT h 215736 BTU/h LPG RemoveRegulator R10 Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 863300 BTU/h LPG RemoveRegulator R50 Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 1379500 BTU/h LPG RemoveRegulator R4 Direct Acting Single Stage LPG 28 mbar M26 X 1.5 x 1/2" NPT h 360450 BTU/h LPG Remove
ImageRegulator R50 OPSO Direct Acting Second Stage GN 23 mbar 1" NPT h x 1" NPT h 40 m³/ h GNRegulator R10 RVI Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 768960 BTU/h LPGRegulator R10 Adjustable Direct Acting First Stage LPG 0.5 - 12.4 psi 3/4" NPT h x 3/4" NPT h 215736 BTU/h LPGRegulator R10 Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 863300 BTU/h LPGRegulator R50 Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 1379500 BTU/h LPGRegulator R4 Direct Acting Single Stage LPG 28 mbar M26 X 1.5 x 1/2" NPT h 360450 BTU/h LPG
Reference414009411245411255411268414001410818
Rating
Stock
Availability
Add to cart

Read more

Read more

Read more

Read more

Read more

Read more

DescriptionRegulator for internal use for residential and industrial gas installations. Reference Standard NTC-3293. With different flow rates according to the application and overpressure cut-off safety device.Regulator for external use for residential installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential and industrial gas installations. Reference Standard With different flow rates according to the application and safety device. Regulator for external use for residential gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
ContentInlet Pressure MIN. 0.28 bar (4.1 psi). MAX Inlet Pressure 2 bar (29 psi). Outlet Pressure 23 mbar (9.2 "w.c.). Flow rate at inlet pressure inlet pressure MIN m³/ h GN 40. with set pressure m³/ h GN 50. Inlet connection 1" NPT h Outlet connection 1" NPT hInlet Pressure MIN. 1.04 bar (15.1 psi). MAX Inlet Pressure. 6.9 bar (100 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate at inlet pressure MIN Flow rate 15.4Kg/h LPG, at set pressure Flow rate 22.1Kg/h LPG. Connection Inlet 1" NPT h Connection Outlet 1" NPT hInlet Pressure MIN. 1 bar (14.5 psi). Inlet Pressure MAX. 4.2 bar (60.9 psi). Outlet Pressure mbar ("c.a.). Flow rate at inlet pressure inlet pressure MIN Flow rate Kg/h LPG: 0. with set pressure Flow rate Kg/h LPG: . Inlet connection 3/4" NPT h Outlet connection 3/4" NPT hInlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 6.9 bar (100 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate with inlet pressure MIN Flow rate 17.3Kg/h LPG, with set pressure Flow rate 30Kg/h LPG. Inlet connection 1" NPT h Outlet connection 1" NPT hInlet Pressure MIN. 0.7 bar (10.2 psi). MAX Inlet Pressure. 5.52 bar (80 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate at inlet pressure MIN Flow rate 27.6Kg/h LPG, at set pressure Flow rate 84.8Kg/h LPG. Inlet connection 1" NPT h Outlet connection 1" NPT h.Inlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 5.5 bar (79.8 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate with inlet pressure MIN Flow rate 7.2Kg/h LPG, with set pressure Flow rate 10.3Kg/h LPG. Inlet connection M26 X 1,5 Outlet connection 1/2" NPT h.
Additional Information
Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Overpressure cutting.

Maximum inlet pressure

29

Minimum inlet pressure

4.1

Outlet pressure

23 mbar

Nominal flow rate

40 m³/ h GN

Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

100

Minimum inlet pressure

15.1

Outlet pressure

28 mbar

Nominal flow rate

768960 BTU/h LPG

Brand

Humcar

Connection Input

3/4" NPT h

Connection Output

3/4" NPT h

Type of Adjustment

Adjustable

Stage

First Stage

Security System

Not applicable.

Maximum inlet pressure

60.9

Minimum inlet pressure

14.5

Outlet pressure

0.5 - 12.4 psi

Nominal flow rate

215736 BTU/h LPG

Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

100

Minimum inlet pressure

20.3

Outlet pressure

28 mbar

Nominal flow rate

863300 BTU/h LPG

Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

80

Minimum inlet pressure

10.2

Outlet pressure

28 mbar

Nominal flow rate

1379500 BTU/h LPG

Brand

Humcar

Connection Input

5, M26 X 1

Connection Output

1/2" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

79.8

Minimum inlet pressure

20.3

Outlet pressure

28 mbar

Nominal flow rate

360450 BTU/h LPG

Cart
No products in the cart.
Notificaciones Judiciales
Email
WhatsApp
Phone
WhatsApp
Phone
Email
Notificaciones Judiciales
Select the fields to display
  • Image
  • Reference
  • Rating
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Additional Information
Click outside the comparison bar to close it.
Compare