Regulator for internal use for residential and commercial gas installations. Reference standard specification ES.02260.MX-CN and standard MX-32-X-SCFI-2013. With different flow rates according to the application and overpressure cut-off safety device.

Description

Inlet Pressure MIN. 0.4 bar (5.8 psi). MAX Inlet Pressure 0.5 bar (7.25 psi). Outlet Pressure 35 mbar (14 "w.c.). Flow rate at inlet pressure
inlet pressure MIN m³/ h GN 25. with set pressure m³/ h GN 25. Inlet connection 1" NPT h Outlet connection 1" NPT h

Additional information

Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Overpressure cutting.

Maximum inlet pressure

7.25

Minimum inlet pressure

5.8

Outlet pressure

35 mbar

Nominal flow rate

25 m³/ h GN

Documents

Quick comparison

Regulator R50 OPSO Direct Acting Second Stage GN 35 mbar 1" NPT h x 1" NPT h 25 m³/ h GN RemoveRegulator R10 UPSO Direct Acting Single Stage GN 21 mbar 3/4" NPT h x 3/4" NPT h 10 m³/ h GN RemoveHigh Pressure Regulator Direct Acting First Stage LPG 10 - 30 psi 1/2" NPT h x 1/2" NPT h 3365482 BTU/h LPG RemoveRegulator R102 Direct Acting Single Stage LPG 28 mbar Quick Coupling Ø35 mm x 3/8" Hose Coupling 64792 BTU/h LPG RemoveRegulator R50 Direct Acting Second Stage LPG 28 mbar 1" NPT h x 1" NPT h 1619800 BTU/h LPG RemoveRegulator R101 Direct Acting Single Stage LPG 28 mbar M11 X 1 x 3/8" NPT h 72090 BTU/h LPG Remove
NameRegulator R50 OPSO Direct Acting Second Stage GN 35 mbar 1" NPT h x 1" NPT h 25 m³/ h GN RemoveRegulator R10 UPSO Direct Acting Single Stage GN 21 mbar 3/4" NPT h x 3/4" NPT h 10 m³/ h GN RemoveHigh Pressure Regulator Direct Acting First Stage LPG 10 - 30 psi 1/2" NPT h x 1/2" NPT h 3365482 BTU/h LPG RemoveRegulator R102 Direct Acting Single Stage LPG 28 mbar Quick Coupling Ø35 mm x 3/8" Hose Coupling 64792 BTU/h LPG RemoveRegulator R50 Direct Acting Second Stage LPG 28 mbar 1" NPT h x 1" NPT h 1619800 BTU/h LPG RemoveRegulator R101 Direct Acting Single Stage LPG 28 mbar M11 X 1 x 3/8" NPT h 72090 BTU/h LPG Remove
ImageRegulator R50 OPSO Direct Acting Second Stage GN 35 mbar 1" NPT h x 1" NPT h 25 m³/ h GNRegulator R10 UPSO Direct Acting Single Stage GN 21 mbar 3/4" NPT h x 3/4" NPT h 10 m³/ h GNHigh Pressure Regulator Direct Acting First Stage LPG 10 - 30 psi 1/2" NPT h x 1/2" NPT h 3365482 BTU/h LPGRegulator R102 Direct Acting Single Stage LPG 28 mbar Quick Coupling Ø35 mm x 3/8" Hose Coupling 64792 BTU/h LPGRegulator R50 Direct Acting Second Stage LPG 28 mbar 1" NPT h x 1" NPT h 1619800 BTU/h LPGRegulator R101 Direct Acting Single Stage LPG 28 mbar M11 X 1 x 3/8" NPT h 72090 BTU/h LPG
Reference414024411206410200610068414003410880
Rating
Stock
Availability
Add to cart

Read more

Read more

Read more

Read more

Read more

Read more

DescriptionRegulator for internal use for residential and commercial gas installations. Reference standard specification ES.02260.MX-CN and standard MX-32-X-SCFI-2013. With different flow rates according to the application and overpressure cut-off safety device.External use regulator for residential and commercial gas installations. Reference Standard MX-032-X-SCFI-2013 and specification ES.02260.MX-CN. With different flow rates according to the application and safety device relief valve and low pressure cut-off (UPSO).External use regulator for commercial and industrial gas installations. Reference Standard NFPA-58 and NTC-3873. With different flow rates according to the application and safety device.Regulator for external use for installations with portable LPG cylinders. Reference Standard NTC-3873 With different flow rates according to the application and safety device. Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
ContentInlet Pressure MIN. 0.4 bar (5.8 psi). MAX Inlet Pressure 0.5 bar (7.25 psi). Outlet Pressure 35 mbar (14 "w.c.). Flow rate at inlet pressure inlet pressure MIN m³/ h GN 25. with set pressure m³/ h GN 25. Inlet connection 1" NPT h Outlet connection 1" NPT hInlet Pressure MIN. 1 bar (14.5 psi). Inlet Pressure MAX. 4 bar (58 psi). Outlet Pressure 21 mbar (8.4 "w.c.). Flow rate at inlet pressure inlet pressure MIN Flow Kg/h LPG: 0. with set pressure m³/ h GN 10. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT hInlet Pressure Min. 2 bar (29 psi). Max. Inlet Pressure 100 psi (6.9 bar). Output Pressure 10 - 30 psi. Flow rate at inlet pressure Max. 3.365.482 BTU/h LPG. Inlet connection 1/2" NPT h Outlet connection 1/2" NPT h.Inlet Pressure MIN. 0.7 bar (10.2 psi). MAX Inlet Pressure. 7.5 bar (108.8 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate at inlet pressure inlet pressure MIN Flow rate Kg/h LPG: 1.3. with set pressure Flow rate Kg/h LPG: . Inlet connection Quick coupling Ø35 mm Outlet connection Hose coupling 3/8".Presión de Entrada MIN. 0.21 bar (3 psi). Presión de Entrada MÁX. 2 bar (29 psi). Presión de Salida 28 mbar (11.2 "c.a.). Caudal con presión de entrada MÍN Caudal Kg/h GLP: 32.5. con presión de ajuste Caudal Kg/h GLP: 46.4285714285714. Conexión Entrada 1” NPT h Conexión Salida 1” NPT hInlet Pressure MIN. 0.7 bar (10.2 psi). MAX Inlet Pressure. 7 bar (100 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate with inlet pressure MIN Flow rate 1.4Kg/h LPG, with set pressure Flow rate 2.6Kg/h LPG. Connection Inlet M11 X 1 Connection Outlet 3/8" NPT h
Additional Information
Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Overpressure cutting.

Maximum inlet pressure

7.25

Minimum inlet pressure

5.8

Outlet pressure

35 mbar

Nominal flow rate

25 m³/ h GN

Brand

Humcar

Connection Input

3/4" NPT h

Connection Output

3/4" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

58

Minimum inlet pressure

14.5

Outlet pressure

21 mbar

Nominal flow rate

10 m³/ h GN

Brand

Humcar

Connection Input

1/2" NPT h

Connection Output

1/2" NPT h

Type of Adjustment

Adjustable

Stage

First Stage

Security System

Not applicable.

Maximum inlet pressure

100 psi

Minimum inlet pressure

29 psi

Outlet pressure

10 - 30 psi

Nominal flow rate

3365482 BTU/h LPG

Brand

By Humcar

Connection Input

Quick Coupling Ø35 mm

Connection Output

3/8" Hose Coupling

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Not applicable.

Maximum inlet pressure

108.8

Minimum inlet pressure

10.2

Outlet pressure

28 mbar

Nominal flow rate

64792 BTU/h LPG

Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Relief Valve.

Maximum inlet pressure

29

Minimum inlet pressure

3

Outlet pressure

28 mbar

Nominal flow rate

1619800 BTU/h LPG

Brand

Humcar

Connection Input

M11 X 1

Connection Output

3/8" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

100

Minimum inlet pressure

10.2

Outlet pressure

28 mbar

Nominal flow rate

72090 BTU/h LPG

Cart
No products in the cart.
Notificaciones Judiciales
Email
WhatsApp
Phone
WhatsApp
Phone
Email
Notificaciones Judiciales
Select the fields to display
  • Image
  • Reference
  • Rating
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Additional Information
Click outside the comparison bar to close it.
Compare