• Home
  • Products
  • Regulador R6 Acción Directa Segunda Etapa GN 100 mbar 1/2” NPT h x 1/2” NPT h 3.2 m³/ h GN

Regulador R6 Acción Directa Segunda Etapa GN 100 mbar 1/2” NPT h x 1/2” NPT h 3.2 m³/ h GN

External use regulator for residential gas installations. Manufactured under NTC-3727 standard. With different flow rates according to the application and safety device relief valve.

Description

Presión de Entrada Mín. 0,21 bar (3 psi). Presión de Entrada Máx. 0,42 bar (6,3 psi). Presión de Salida 100 mbar (40 “c.a.). Caudal con presión de entrada Mín. 3,2 m³/ h GN. Con presión de ajuste 4 m³/ h GN. Conexión Entrada 1/2” NPT h Conexión Salida 1/2” NPT h.

Additional information

Brand

Humcar

Connection Input

1/2" NPT h

Connection Output

1/2" NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Relief Valve.

Maximum inlet pressure

6,3 psi

Minimum inlet pressure

3 psi

Outlet pressure

100 mbar

Max. flow rate

3.2 m³/h GN

Nominal flow rate

4 m³/ h GN

Documents

Quick comparison

Regulador R6 Acción Directa Segunda Etapa GN 100 mbar 1/2” NPT h x 1/2” NPT h 3.2 m³/ h GN RemoverLow Pressure Cut-Off Regulator RCBP Self-Compensating Second Stage GN 35 mbar 1/2" NPT h x 1/2" NPT h 12 m³/ h GN RemoveRegulator R10 Direct Acting First Stage LPG 15 psi 3/4" NPT h x 3/4" NPT h 1691000 BTU/h LPG RemoveLow Pressure Cut-Off Regulator RCBP Self-Compensating Second Stage GN 50 mbar 1/2" NPT h x 1/2" NPT h 20 m³/ h GN RemoveRegulator R10 UPSO Direct Acting Single Stage GN 21 mbar 3/4" NPT h x 3/4" NPT h 10 m³/ h GN RemoveRegulator R50 Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 1379500 BTU/h LPG Remove
NameRegulador R6 Acción Directa Segunda Etapa GN 100 mbar 1/2” NPT h x 1/2” NPT h 3.2 m³/ h GN RemoverLow Pressure Cut-Off Regulator RCBP Self-Compensating Second Stage GN 35 mbar 1/2" NPT h x 1/2" NPT h 12 m³/ h GN RemoveRegulator R10 Direct Acting First Stage LPG 15 psi 3/4" NPT h x 3/4" NPT h 1691000 BTU/h LPG RemoveLow Pressure Cut-Off Regulator RCBP Self-Compensating Second Stage GN 50 mbar 1/2" NPT h x 1/2" NPT h 20 m³/ h GN RemoveRegulator R10 UPSO Direct Acting Single Stage GN 21 mbar 3/4" NPT h x 3/4" NPT h 10 m³/ h GN RemoveRegulator R50 Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 1379500 BTU/h LPG Remove
ImageRegulador R6 Acción Directa Segunda Etapa GN  100 mbar 1/2” NPT h x 1/2” NPT h 3.2 m³/ h GNLow Pressure Cut-Off Regulator RCBP Self-Compensating Second Stage GN 35 mbar 1/2" NPT h x 1/2" NPT h 12 m³/ h GNRegulator R10 Direct Acting First Stage LPG 15 psi 3/4" NPT h x 3/4" NPT h 1691000 BTU/h LPGLow Pressure Cut-Off Regulator RCBP Self-Compensating Second Stage GN 50 mbar 1/2" NPT h x 1/2" NPT h 20 m³/ h GNRegulator R10 UPSO Direct Acting Single Stage GN 21 mbar 3/4" NPT h x 3/4" NPT h 10 m³/ h GNRegulator R50 Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 1379500 BTU/h LPG
Reference410905411504411261411518411206414001
Rating
Stock
Availability
Add to cart

Read more

Read more

Read more

Read more

Read more

Read more

DescriptionExternal use regulator for residential gas installations. Manufactured under NTC-3727 standard. With different flow rates according to the application and safety device relief valve.Regulator for internal use for residential gas installations. Reference Standard NTC-3293. With different flow rates according to the application and safety device Proportional Shut-Off and Low Pressure Cut-Off at the inlet.Regulator for external use for residential and commercial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for internal use for residential gas installations. Reference Standard NTC-3293. With different flow rates according to the application and safety device Proportional Shut-Off and Low Pressure Cut-Off at the inlet.External use regulator for residential and commercial gas installations. Reference Standard MX-032-X-SCFI-2013 and specification ES.02260.MX-CN. With different flow rates according to the application and safety device relief valve and low pressure cut-off (UPSO).Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
ContentPresión de Entrada Mín. 0,21 bar (3 psi). Presión de Entrada Máx. 0,42 bar (6,3 psi). Presión de Salida 100 mbar (40 "c.a.). Caudal con presión de entrada Mín. 3,2 m³/ h GN. Con presión de ajuste 4 m³/ h GN. Conexión Entrada 1/2” NPT h Conexión Salida 1/2” NPT h.Inlet Pressure MIN. bar (1.5 psi). Inlet Pressure MAX. bar (9.9 psi). Outlet Pressure 35 mbar (14 "w.c.). Flow rate at inlet pressure inlet pressure MIN. m³/ h GN 12. with set pressure m³/ h GN 23. Inlet connection 1/2" NPT h Outlet connection 1/2" NPT hInlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 6.9 bar (100 psi). Outlet Pressure 15 psi (1034 mbar). Flow rate with inlet pressure MIN Flow rate 33.9 Kg/h LPG, with set pressure Flow rate 105.7 Kg/h LPG. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT h.Inlet Pressure MIN. bar (3 psi). Inlet Pressure MAX. bar (10 psi). Outlet Pressure 50 mbar (20 "c.a.). Flow rate at inlet pressure inlet pressure MIN. m³/ h GN 20. with set pressure m³/ h GN 19. Inlet connection 1/2" NPT h Outlet connection 1/2" NPT hInlet Pressure MIN. 1 bar (14.5 psi). Inlet Pressure MAX. 4 bar (58 psi). Outlet Pressure 21 mbar (8.4 "w.c.). Flow rate at inlet pressure inlet pressure MIN Flow Kg/h LPG: 0. with set pressure m³/ h GN 10. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT hInlet Pressure MIN. 0.7 bar (10.2 psi). MAX Inlet Pressure. 5.52 bar (80 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate at inlet pressure MIN Flow rate 27.6Kg/h LPG, at set pressure Flow rate 84.8Kg/h LPG. Inlet connection 1" NPT h Outlet connection 1" NPT h.
Additional Information
Brand

Humcar

Connection Input

1/2" NPT h

Connection Output

1/2" NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Relief Valve.

Maximum inlet pressure

6,3 psi

Minimum inlet pressure

3 psi

Outlet pressure

100 mbar

Max. flow rate

3.2 m³/h GN

Nominal flow rate

4 m³/ h GN

Brand

Humcar

Connection Input

1/2" NPT h

Connection Output

1/2" NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Proportional shut-off and low pressure cut-off at the inlet.

Maximum inlet pressure

9.9

Minimum inlet pressure

1.5

Outlet pressure

35 mbar

Nominal flow rate

12 m³/ h GN

Brand

Humcar

Connection Input

3/4" NPT h

Connection Output

3/4" NPT h

Type of Adjustment

Not Adjustable

Stage

First Stage

Security System

Relief Valve.

Maximum inlet pressure

100

Minimum inlet pressure

20.3

Outlet pressure

15 psi

Nominal flow rate

1691000 BTU/h LPG

Brand

Humcar

Connection Input

1/2" NPT h

Connection Output

1/2" NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Proportional shut-off and low pressure cut-off at the inlet.

Maximum inlet pressure

10

Minimum inlet pressure

3

Outlet pressure

50 mbar

Nominal flow rate

20 m³/ h GN

Brand

Humcar

Connection Input

3/4" NPT h

Connection Output

3/4" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

58

Minimum inlet pressure

14.5

Outlet pressure

21 mbar

Nominal flow rate

10 m³/ h GN

Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

80

Minimum inlet pressure

10.2

Outlet pressure

28 mbar

Nominal flow rate

1379500 BTU/h LPG

Cart
No products in the cart.
Notificaciones Judiciales
Email
WhatsApp
Phone
WhatsApp
Phone
Email
Notificaciones Judiciales
Select the fields to display
  • Image
  • Reference
  • Rating
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Additional Information
Click outside the comparison bar to close it.
Compare