• Home
  • Products
  • Regulador R6 Acción Directa Única Etapa GN 19 mbar 1/2” NPT h x 1/2” NPT h 3.2 m³/ h GN

Regulador R6 Acción Directa Única Etapa GN 19 mbar 1/2” NPT h x 1/2” NPT h 3.2 m³/ h GN

External use regulator for residential gas installations. Manufactured under NTC-3727 standard. With different flow rates according to the application and safety device relief valve.

Description

Presión de Entrada Mín. 1,72 bar (24,9 psi). Presión de Entrada Máx. 4 bar (58 psi). Presión de Salida 19 mbar (7.6 “c.a.). Caudal con presión de entrada Mín. 3,2 m³/ h GN. Con presión de ajuste 8,72 m³/ h GN. Conexión Entrada 1/2” NPT h Conexión Salida 1/2” NPT h.

Additional information

Brand

Humcar

Connection Input

1/2" NPT h

Connection Output

1/2" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

58 psi

Minimum inlet pressure

24.9 psi

Outlet pressure

19 mbar

Max. flow rate

3.2 m³/h GN

Nominal flow rate

8.72 m³/h GN

Documents

Quick comparison

Regulador R6 Acción Directa Única Etapa GN 19 mbar 1/2” NPT h x 1/2” NPT h 3.2 m³/ h GN RemoverRegulator R50 Direct Acting Second Stage GN 21 mbar 1 NPT h x 1 NPT h 43 m³/ h GN RemoveRegulator R10 RVI Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 768960 BTU/h LPG RemoveRegulator R10 RVI Direct Acting Single Stage LPG 28 mbar 3/4" NPT h x 3/4" NPT h 768960 BTU/h LPG RemoveRegulator R101 Direct Acting Single Stage LPG 28 mbar M11 X 1 x 3/8" NPT h 72090 BTU/h LPG RemoveRegulator R10 Direct Acting First Stage LPG 350 mbar 1" NPT h x 1" NPT h 2207200 BTU/h LPG Remove
NameRegulador R6 Acción Directa Única Etapa GN 19 mbar 1/2” NPT h x 1/2” NPT h 3.2 m³/ h GN RemoverRegulator R50 Direct Acting Second Stage GN 21 mbar 1 NPT h x 1 NPT h 43 m³/ h GN RemoveRegulator R10 RVI Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 768960 BTU/h LPG RemoveRegulator R10 RVI Direct Acting Single Stage LPG 28 mbar 3/4" NPT h x 3/4" NPT h 768960 BTU/h LPG RemoveRegulator R101 Direct Acting Single Stage LPG 28 mbar M11 X 1 x 3/8" NPT h 72090 BTU/h LPG RemoveRegulator R10 Direct Acting First Stage LPG 350 mbar 1" NPT h x 1" NPT h 2207200 BTU/h LPG Remove
ImageRegulador R6 Acción Directa Única Etapa GN  19 mbar 1/2” NPT h x 1/2” NPT h 3.2 m³/ h GNRegulator R50 Direct Acting Second Stage GN 21 mbar 1 NPT h x 1 NPT h 43 m³/ h GNRegulator R10 RVI Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 768960 BTU/h LPGRegulator R10 RVI Direct Acting Single Stage LPG 28 mbar 3/4" NPT h x 3/4" NPT h 768960 BTU/h LPGRegulator R101 Direct Acting Single Stage LPG 28 mbar M11 X 1 x 3/8" NPT h 72090 BTU/h LPGRegulator R10 Direct Acting First Stage LPG 350 mbar 1" NPT h x 1" NPT h 2207200 BTU/h LPG
Reference410919414054411245411243410880411258
Rating
Stock
Availability
Add to cart

Read more

Read more

Read more

Read more

Read more

Read more

DescriptionExternal use regulator for residential gas installations. Manufactured under NTC-3727 standard. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3727. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
ContentPresión de Entrada Mín. 1,72 bar (24,9 psi). Presión de Entrada Máx. 4 bar (58 psi). Presión de Salida 19 mbar (7.6 "c.a.). Caudal con presión de entrada Mín. 3,2 m³/ h GN. Con presión de ajuste 8,72 m³/ h GN. Conexión Entrada 1/2” NPT h Conexión Salida 1/2” NPT h.Inlet Pressure MIN. 0.14 bar (2 psi). MAX Inlet Pressure 0.35 bar (5 psi). Outlet Pressure 21 mbar (8.4 "w.c.). Flow rate at inlet pressure inlet pressure MIN Flow rate Kg/h LPG: 0. with set pressure m³/ h GN 43. Inlet connection 1 NPT h Outlet connection 1 NPT hInlet Pressure MIN. 1.04 bar (15.1 psi). MAX Inlet Pressure. 6.9 bar (100 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate at inlet pressure MIN Flow rate 15.4Kg/h LPG, at set pressure Flow rate 22.1Kg/h LPG. Connection Inlet 1" NPT h Connection Outlet 1" NPT hInlet Pressure MIN. 1.04 bar (15.1 psi). MAX Inlet Pressure. 6.9 bar (100 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate with inlet pressure MIN Flow rate 15.4Kg/h LPG, with set pressure Flow rate 22.1Kg/h LPG. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT h.Inlet Pressure MIN. 0.7 bar (10.2 psi). MAX Inlet Pressure. 7 bar (100 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate with inlet pressure MIN Flow rate 1.4Kg/h LPG, with set pressure Flow rate 2.6Kg/h LPG. Connection Inlet M11 X 1 Connection Outlet 3/8" NPT hInlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 5.52 bar (80 psi). Outlet Pressure 350 mbar (140 "w.c.). Flow rate at inlet pressure MIN Flow rate 44.2Kg/h LPG, at set pressure Flow rate 53.3Kg/h LPG. Inlet connection 1" NPT h Outlet connection 1" NPT h.
Additional Information
Brand

Humcar

Connection Input

1/2" NPT h

Connection Output

1/2" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

58 psi

Minimum inlet pressure

24.9 psi

Outlet pressure

19 mbar

Max. flow rate

3.2 m³/h GN

Nominal flow rate

8.72 m³/h GN

Brand

Humcar

Connection Input

1 NPT h

Connection Output

1 NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Relief Valve.

Maximum inlet pressure

5

Minimum inlet pressure

2

Outlet pressure

21 mbar

Nominal flow rate

43 m³/ h GN

Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

100

Minimum inlet pressure

15.1

Outlet pressure

28 mbar

Nominal flow rate

768960 BTU/h LPG

Brand

Humcar

Connection Input

3/4" NPT h

Connection Output

3/4" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

100

Minimum inlet pressure

15.1

Outlet pressure

28 mbar

Nominal flow rate

768960 BTU/h LPG

Brand

Humcar

Connection Input

M11 X 1

Connection Output

3/8" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

100

Minimum inlet pressure

10.2

Outlet pressure

28 mbar

Nominal flow rate

72090 BTU/h LPG

Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

First Stage

Security System

Relief Valve.

Maximum inlet pressure

80

Minimum inlet pressure

20.3

Outlet pressure

350 mbar

Nominal flow rate

2207200 BTU/h LPG

Cart
No products in the cart.
Notificaciones Judiciales
Email
WhatsApp
Phone
WhatsApp
Phone
Email
Notificaciones Judiciales
Select the fields to display
  • Image
  • Reference
  • Rating
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Additional Information
Click outside the comparison bar to close it.
Compare