• Home
  • Products
  • Regulator R7 UPSO 90° Direct Acting First Stage GN 340 mbar G3/4 m x G 3/4 h JP 7.5 m³/ h GN

Regulator R7 UPSO 90° Direct Acting First Stage GN 340 mbar G3/4 m x G 3/4 h JP 7.5 m³/ h GN

Regulator for external use for residential gas installations. Reference Standard NTC-3727. With different flow rates according to the application and safety device Relief valve, low pressure cut-off at the inlet and diaphragm rupture.

Description

Inlet Pressure MIN. 1 bar (14.5 psi). Inlet Pressure MAX. 5 bar (72.5 psi). Outlet Pressure 340 mbar (136 "c.a.). Flow rate at inlet pressure
inlet pressure MIN m³/ h GN 7.5. with set pressure m³/ h GN 10.5. Connection Inlet G3/4 m Connection Outlet G 3/4 h JP

Additional information

Brand

Humcar

Connection Input

G3/4 m

Connection Output

G 3/4 h JP

Type of Adjustment

Not Adjustable

Stage

First Stage

Security System

low inlet pressure shutdown and diaphragm rupture, Relief Valve, Relief Valve

Maximum inlet pressure

72.5

Minimum inlet pressure

14.5

Outlet pressure

340 mbar

Nominal flow rate

7.5 m³/ h GN

Documents

Quick comparison

Regulator R7 UPSO 90° Direct Acting First Stage GN 340 mbar G3/4 m x G 3/4 h JP 7.5 m³/ h GN RemoveLow Pressure Cut-Off Regulator RCBP Self-Compensating Second Stage GN 50 mbar 1/2" NPT h x 1/2" NPT h 20 m³/ h GN RemoveRegulator R10 Direct Acting Second Stage LPG 28mbar 3/4 "NPTh x 3/4 "NPTh 445000 BTU/h LPG RemoveRegulator R10 Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 863300 BTU/h LPG RemoveRegulator R10 UPSO Direct Acting Single Stage GN 21 mbar 3/4" NPT h x 3/4" NPT h 10 m³/ h GN RemoveRegulator R10 Direct Acting First Stage LPG 350 mbar 1" NPT h x 1" NPT h 2207200 BTU/h LPG Remove
NameRegulator R7 UPSO 90° Direct Acting First Stage GN 340 mbar G3/4 m x G 3/4 h JP 7.5 m³/ h GN RemoveLow Pressure Cut-Off Regulator RCBP Self-Compensating Second Stage GN 50 mbar 1/2" NPT h x 1/2" NPT h 20 m³/ h GN RemoveRegulator R10 Direct Acting Second Stage LPG 28mbar 3/4 "NPTh x 3/4 "NPTh 445000 BTU/h LPG RemoveRegulator R10 Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 863300 BTU/h LPG RemoveRegulator R10 UPSO Direct Acting Single Stage GN 21 mbar 3/4" NPT h x 3/4" NPT h 10 m³/ h GN RemoveRegulator R10 Direct Acting First Stage LPG 350 mbar 1" NPT h x 1" NPT h 2207200 BTU/h LPG Remove
ImageRegulator R7 UPSO 90° Direct Acting First Stage GN 340 mbar G3/4 m x G 3/4 h JP 7.5 m³/ h GNLow Pressure Cut-Off Regulator RCBP Self-Compensating Second Stage GN 50 mbar 1/2" NPT h x 1/2" NPT h 20 m³/ h GNRegulator R10 Direct Action Second Stage LPG 28mbar 3/4 "NPTh x 3/4 "NPTh 445000 BTU/h LPGRegulator R10 Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 863300 BTU/h LPGRegulator R10 UPSO Direct Acting Single Stage GN 21 mbar 3/4" NPT h x 3/4" NPT h 10 m³/ h GNRegulator R10 Direct Acting First Stage LPG 350 mbar 1" NPT h x 1" NPT h 2207200 BTU/h LPG
Reference411069411518411265411268411206411258
Rating
Stock
Availability
Add to cart

Read more

Read more

Read more

Read more

Read more

Read more

DescriptionRegulator for external use for residential gas installations. Reference Standard NTC-3727. With different flow rates according to the application and safety device Relief valve, low pressure cut-off at the inlet and diaphragm rupture.Regulator for internal use for residential gas installations. Reference Standard NTC-3293. With different flow rates according to the application and safety device Proportional Shut-Off and Low Pressure Cut-Off at the inlet.Regulator for external use for residential gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device.External use regulator for residential and commercial gas installations. Reference Standard MX-032-X-SCFI-2013 and specification ES.02260.MX-CN. With different flow rates according to the application and safety device relief valve and low pressure cut-off (UPSO).Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
ContentInlet Pressure MIN. 1 bar (14.5 psi). Inlet Pressure MAX. 5 bar (72.5 psi). Outlet Pressure 340 mbar (136 "c.a.). Flow rate at inlet pressure inlet pressure MIN m³/ h GN 7.5. with set pressure m³/ h GN 10.5. Connection Inlet G3/4 m Connection Outlet G 3/4 h JPInlet Pressure MIN. bar (3 psi). Inlet Pressure MAX. bar (10 psi). Outlet Pressure 50 mbar (20 "c.a.). Flow rate at inlet pressure inlet pressure MIN. m³/ h GN 20. with set pressure m³/ h GN 19. Inlet connection 1/2" NPT h Outlet connection 1/2" NPT hMin. inlet pressure 0.2 bar (2.9 psi). Max. inlet pressure 1.4 bar (20.3 psi). Outlet pressure 28 mbar (11,2 "c.a.). Flow rate at min. inlet pressure 8.9 kg/h LPG (445,000 BTU/h LPG). Flow rate at set pressure 13.7Kg/h LPG (685,300 BTU/h LPG). Inlet connection 3/4" NPT h Outlet connection 3/4" NPT hInlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 6.9 bar (100 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate with inlet pressure MIN Flow rate 17.3Kg/h LPG, with set pressure Flow rate 30Kg/h LPG. Inlet connection 1" NPT h Outlet connection 1" NPT hInlet Pressure MIN. 1 bar (14.5 psi). Inlet Pressure MAX. 4 bar (58 psi). Outlet Pressure 21 mbar (8.4 "w.c.). Flow rate at inlet pressure inlet pressure MIN Flow Kg/h LPG: 0. with set pressure m³/ h GN 10. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT hInlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 5.52 bar (80 psi). Outlet Pressure 350 mbar (140 "w.c.). Flow rate at inlet pressure MIN Flow rate 44.2Kg/h LPG, at set pressure Flow rate 53.3Kg/h LPG. Inlet connection 1" NPT h Outlet connection 1" NPT h.
Additional Information
Brand

Humcar

Connection Input

G3/4 m

Connection Output

G 3/4 h JP

Type of Adjustment

Not Adjustable

Stage

First Stage

Security System

low inlet pressure shutdown and diaphragm rupture, Relief Valve, Relief Valve

Maximum inlet pressure

72.5

Minimum inlet pressure

14.5

Outlet pressure

340 mbar

Nominal flow rate

7.5 m³/ h GN

Brand

Humcar

Connection Input

1/2" NPT h

Connection Output

1/2" NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Proportional shut-off and low pressure cut-off at the inlet.

Maximum inlet pressure

10

Minimum inlet pressure

3

Outlet pressure

50 mbar

Nominal flow rate

20 m³/ h GN

Brand

Humcar

Connection Input

3/4" NPT h

Connection Output

3/4" NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Relief Valve.

Maximum inlet pressure

20.3 psi

Minimum inlet pressure

2.9 psi

Outlet pressure

28 mbar

Nominal flow rate

445000 BTU/h LPG

Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

100

Minimum inlet pressure

20.3

Outlet pressure

28 mbar

Nominal flow rate

863300 BTU/h LPG

Brand

Humcar

Connection Input

3/4" NPT h

Connection Output

3/4" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

58

Minimum inlet pressure

14.5

Outlet pressure

21 mbar

Nominal flow rate

10 m³/ h GN

Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

First Stage

Security System

Relief Valve.

Maximum inlet pressure

80

Minimum inlet pressure

20.3

Outlet pressure

350 mbar

Nominal flow rate

2207200 BTU/h LPG

Cart
No products in the cart.
Notificaciones Judiciales
Email
WhatsApp
Phone
WhatsApp
Phone
Email
Notificaciones Judiciales
Select the fields to display
  • Image
  • Reference
  • Rating
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Additional Information
Click outside the comparison bar to close it.
Compare