TEST HEAD KIT WITH PRESSURE GAUGE AND FLEXIBLE CONNECTOR

Kit unit weight: 2,8 Kg

SKU: 430126 Categories: ,

Description

Device provided with pressure gauge, connector, hoses and calibrated nozzles. It allows to verify the tightness of a network and also to check if at a certain flow rate (simulated through nozzles) the desired pressure is reached at the outlet of the system or regulator.

Additional information

Brand

By Humcar

Operating Gas

Natural Gas

Nozzles

Internal Ø 1- 2- 3 - 4 - 5 - 6 mm with M26 connections.

Pressure gauge

Range: 0 - 2,000 mbar (0 - 29 psi)
Resolution: 1 mbar (0.01 psi)
Pressure unit: psi, mm Hg, bar, mbar, Kpa, in. w.c.

Documents

Quick comparison

TEST HEAD KIT WITH PRESSURE GAUGE AND FLEXIBLE CONNECTOR RemoveR7 Regulator Direct Acting Single Stage LPG 28mbar 3/4 "NPTh x 3/4 "NPTh 431650BTU/h LPG RemoveRegulator R4 Direct Acting Single Stage LPG 28 mbar M26 X 1.5 x 1/2" NPT h 360450 BTU/h LPG RemoveRegulator R10 Direct Acting First Stage LPG 350 mbar 1" NPT h x 1" NPT h 2207200 BTU/h LPG RemoveRegulator R50 Direct Acting Second Stage LPG 28 mbar 1" NPT h x 1" NPT h 1619800 BTU/h LPG RemoveRegulator R50 Direct Acting Second Stage GN 21 mbar 1 NPT h x 1 NPT h 43 m³/ h GN Remove
NameTEST HEAD KIT WITH PRESSURE GAUGE AND FLEXIBLE CONNECTOR RemoveR7 Regulator Direct Acting Single Stage LPG 28mbar 3/4 "NPTh x 3/4 "NPTh 431650BTU/h LPG RemoveRegulator R4 Direct Acting Single Stage LPG 28 mbar M26 X 1.5 x 1/2" NPT h 360450 BTU/h LPG RemoveRegulator R10 Direct Acting First Stage LPG 350 mbar 1" NPT h x 1" NPT h 2207200 BTU/h LPG RemoveRegulator R50 Direct Acting Second Stage LPG 28 mbar 1" NPT h x 1" NPT h 1619800 BTU/h LPG RemoveRegulator R50 Direct Acting Second Stage GN 21 mbar 1 NPT h x 1 NPT h 43 m³/ h GN Remove
ImageTEST HEAD KIT WITH PRESSURE GAUGE AND FLEXIBLE CONNECTORR7 Regulator Direct Acting Single Stage LPG 28mbar 3/4 "NPTh x 3/4 "NPTh 431650BTU/h LPGRegulator R4 Direct Acting Single Stage LPG 28 mbar M26 X 1.5 x 1/2" NPT h 360450 BTU/h LPGRegulator R10 Direct Acting First Stage LPG 350 mbar 1" NPT h x 1" NPT h 2207200 BTU/h LPGRegulator R50 Direct Acting Second Stage LPG 28 mbar 1" NPT h x 1" NPT h 1619800 BTU/h LPGRegulator R50 Direct Acting Second Stage GN 21 mbar 1 NPT h x 1 NPT h 43 m³/ h GN
Reference430126411022410818411258414003414054
Rating
Stock

Available for reservation

AvailabilityAvailable for reservation
Add to cart

Read more

Read more

Read more

Read more

Read more

Read more

DescriptionKit unit weight: 2,8 KgRegulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3727. With different flow rates according to the application and safety device relief valve.
ContentDevice provided with pressure gauge, connector, hoses and calibrated nozzles. It allows to verify the tightness of a network and also to check if at a certain flow rate (simulated through nozzles) the desired pressure is reached at the outlet of the system or regulator.Inlet pressure min. 1 bar (14.5 psi). Max. inlet pressure 6.9 bar (100 psi). Outlet Pressure 28 mbar (11.2 "c.a.). Flow rate at min. inlet pressure Flow rate 8.6Kg/h LPG (431,650 BTU/h LPG), at set pressure Flow rate 26.5Kg/h LPG (1,323,430 BTU/h LPG). Inlet connection 3/4" NPTh Inlet connection 3/4" NPTh Outlet connection.Inlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 5.5 bar (79.8 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate with inlet pressure MIN Flow rate 7.2Kg/h LPG, with set pressure Flow rate 10.3Kg/h LPG. Inlet connection M26 X 1,5 Outlet connection 1/2" NPT h.Inlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 5.52 bar (80 psi). Outlet Pressure 350 mbar (140 "w.c.). Flow rate at inlet pressure MIN Flow rate 44.2Kg/h LPG, at set pressure Flow rate 53.3Kg/h LPG. Inlet connection 1" NPT h Outlet connection 1" NPT h.Inlet Pressure MIN. 0.21 bar (3 psi). MAX Inlet Pressure 2 bar (29 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate at inlet pressure inlet pressure MIN Flow rate Kg/h LPG: 32.5. with set pressure Flow rate Kg/h LPG: 46.4285714285714. Inlet connection 1" NPT h Outlet connection 1" NPT hInlet Pressure MIN. 0.14 bar (2 psi). MAX Inlet Pressure 0.35 bar (5 psi). Outlet Pressure 21 mbar (8.4 "w.c.). Flow rate at inlet pressure inlet pressure MIN Flow rate Kg/h LPG: 0. with set pressure m³/ h GN 43. Inlet connection 1 NPT h Outlet connection 1 NPT h
Additional Information
Brand

By Humcar

Operating Gas

Natural Gas

Nozzles

Internal Ø 1- 2- 3 - 4 - 5 - 6 mm with M26 connections.

Pressure gauge

Range: 0 - 2,000 mbar (0 - 29 psi)
Resolution: 1 mbar (0.01 psi)
Pressure unit: psi, mm Hg, bar, mbar, Kpa, in. w.c.

Brand

Humcar

Connection Input

3/4" NPT h

Connection Output

3/4" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

100 psi

Minimum inlet pressure

14.5 psi

Outlet pressure

28 mbar

Nominal flow rate

431650 BTU/h LPG

Brand

Humcar

Connection Input

5, M26 X 1

Connection Output

1/2" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

79.8

Minimum inlet pressure

20.3

Outlet pressure

28 mbar

Nominal flow rate

360450 BTU/h LPG

Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

First Stage

Security System

Relief Valve.

Maximum inlet pressure

80

Minimum inlet pressure

20.3

Outlet pressure

350 mbar

Nominal flow rate

2207200 BTU/h LPG

Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Relief Valve.

Maximum inlet pressure

29

Minimum inlet pressure

3

Outlet pressure

28 mbar

Nominal flow rate

1619800 BTU/h LPG

Brand

Humcar

Connection Input

1 NPT h

Connection Output

1 NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Relief Valve.

Maximum inlet pressure

5

Minimum inlet pressure

2

Outlet pressure

21 mbar

Nominal flow rate

43 m³/ h GN

Cart
No products in the cart.
Notificaciones Judiciales
Email
WhatsApp
Phone
WhatsApp
Phone
Email
Notificaciones Judiciales
Select the fields to display
  • Image
  • Reference
  • Rating
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Additional Information
Click outside the comparison bar to close it.
Compare