  • RTB Regulator Direct Acting First Stage GN-GLP 10-30PSI 1″NPTh x 1″NPTh

RTB Regulator Direct Acting First Stage GN-GLP 10-30PSI 1″NPTh x 1″NPTh

First stage regulator used in the handling of Natural Gas (N.G.) and Propane Gas (LPG) for commercial and industrial networks. ANSI/CAN/UL 144:2021 reference standard. Adjustable regulator, no relief valve.

Description

Presión de Entrada mín. 1,4 bar (20 psi). Presión de Entrada Máx. 8,6 bar (125 psi). Rango Presión de Salida 10 – 30 psi. Caudal con presión de entrada Mín. 31,2m³/ h GN – 1.792.047BTU/h GLP. Caudal con presión de ajuste 299 m³/h GN – 17.223.643 BTU/h GLP. Conexión Entrada 1” NPT h Conexión Salida 1” NPT h.

Additional information

Brand

Humcar

Connection Input

1 NPT h

Connection Output

1 NPT h

Type of Adjustment

Adjustable

Stage

First Stage

Security System

Not applicable.

Maximum inlet pressure

125 psi

Minimum inlet pressure

20 psi

Outlet pressure

10 - 30 psi

Nominal flow rate

17.223.643 BTU/h LPG, 299 m³/h NG

Documents

Quick comparison

Direct Acting RTB Regulator First Stage GN-GLP 10-30PSI 1 "NPTh x 1 "NPTh RemoveR7 Regulator Direct Acting Single Stage LPG 28mbar 3/4 "NPTh x 3/4 "NPTh 431650BTU/h LPG RemoveRegulator R50 Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 1379500 BTU/h LPG RemoveRegulator R10 Direct Acting First Stage LPG 350 mbar 1" NPT h x 1" NPT h 2207200 BTU/h LPG RemoveRegulator R102 Direct Acting Single Stage LPG 28 mbar Quick Coupling Ø35 mm x 3/8" Hose Coupling 64792 BTU/h LPG RemoveRegulator R4 Direct Acting Single Stage LPG 28 mbar M26 X 1.5 x 1/2" NPT h 360450 BTU/h LPG Remove
NameDirect Acting RTB Regulator First Stage GN-GLP 10-30PSI 1 "NPTh x 1 "NPTh RemoveR7 Regulator Direct Acting Single Stage LPG 28mbar 3/4 "NPTh x 3/4 "NPTh 431650BTU/h LPG RemoveRegulator R50 Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 1379500 BTU/h LPG RemoveRegulator R10 Direct Acting First Stage LPG 350 mbar 1" NPT h x 1" NPT h 2207200 BTU/h LPG RemoveRegulator R102 Direct Acting Single Stage LPG 28 mbar Quick Coupling Ø35 mm x 3/8" Hose Coupling 64792 BTU/h LPG RemoveRegulator R4 Direct Acting Single Stage LPG 28 mbar M26 X 1.5 x 1/2" NPT h 360450 BTU/h LPG Remove
ImageDirect Acting RTB Regulator First Stage GN-GLP 10-30PSI 1 "NPTh x 1 "NPThR7 Regulator Direct Acting Single Stage LPG 28mbar 3/4 "NPTh x 3/4 "NPTh 431650BTU/h LPGRegulator R50 Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 1379500 BTU/h LPGRegulator R10 Direct Acting First Stage LPG 350 mbar 1" NPT h x 1" NPT h 2207200 BTU/h LPGRegulator R102 Direct Acting Single Stage LPG 28 mbar Quick Coupling Ø35 mm x 3/8" Hose Coupling 64792 BTU/h LPGRegulator R4 Direct Acting Single Stage LPG 28 mbar M26 X 1.5 x 1/2" NPT h 360450 BTU/h LPG
Reference414074411022414001411258610068410818
Rating
Stock
Availability
Add to cart

Read more

Read more

Read more

Read more

Read more

Read more

Description
First stage regulator used in the handling of Natural Gas (N.G.) and Propane Gas (LPG) for commercial and industrial networks. ANSI/CAN/UL 144:2021 reference standard. Adjustable regulator, no relief valve.
Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for installations with portable LPG cylinders. Reference Standard NTC-3873 With different flow rates according to the application and safety device. Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
ContentPresión de Entrada mín. 1,4 bar (20 psi). Presión de Entrada Máx. 8,6 bar (125 psi). Rango Presión de Salida 10 - 30 psi. Caudal con presión de entrada Mín. 31,2m³/ h GN - 1.792.047BTU/h GLP. Caudal con presión de ajuste 299 m³/h GN - 17.223.643 BTU/h GLP. Conexión Entrada 1” NPT h Conexión Salida 1” NPT h.Inlet pressure min. 1 bar (14.5 psi). Max. inlet pressure 6.9 bar (100 psi). Outlet Pressure 28 mbar (11.2 "c.a.). Flow rate at min. inlet pressure Flow rate 8.6Kg/h LPG (431,650 BTU/h LPG), at set pressure Flow rate 26.5Kg/h LPG (1,323,430 BTU/h LPG). Inlet connection 3/4" NPTh Inlet connection 3/4" NPTh Outlet connection.Inlet Pressure MIN. 0.7 bar (10.2 psi). MAX Inlet Pressure. 5.52 bar (80 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate at inlet pressure MIN Flow rate 27.6Kg/h LPG, at set pressure Flow rate 84.8Kg/h LPG. Inlet connection 1" NPT h Outlet connection 1" NPT h.Inlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 5.52 bar (80 psi). Outlet Pressure 350 mbar (140 "w.c.). Flow rate at inlet pressure MIN Flow rate 44.2Kg/h LPG, at set pressure Flow rate 53.3Kg/h LPG. Inlet connection 1" NPT h Outlet connection 1" NPT h.Inlet Pressure MIN. 0.7 bar (10.2 psi). MAX Inlet Pressure. 7.5 bar (108.8 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate at inlet pressure inlet pressure MIN Flow rate Kg/h LPG: 1.3. with set pressure Flow rate Kg/h LPG: . Inlet connection Quick coupling Ø35 mm Outlet connection Hose coupling 3/8".Inlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 5.5 bar (79.8 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate with inlet pressure MIN Flow rate 7.2Kg/h LPG, with set pressure Flow rate 10.3Kg/h LPG. Inlet connection M26 X 1,5 Outlet connection 1/2" NPT h.
Additional Information
Brand

Humcar

Connection Input

1 NPT h

Connection Output

1 NPT h

Type of Adjustment

Adjustable

Stage

First Stage

Security System

Not applicable.

Maximum inlet pressure

125 psi

Minimum inlet pressure

20 psi

Outlet pressure

10 - 30 psi

Nominal flow rate

17.223.643 BTU/h LPG, 299 m³/h NG

Brand

Humcar

Connection Input

3/4" NPT h

Connection Output

3/4" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

100 psi

Minimum inlet pressure

14.5 psi

Outlet pressure

28 mbar

Nominal flow rate

431650 BTU/h LPG

Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

80

Minimum inlet pressure

10.2

Outlet pressure

28 mbar

Nominal flow rate

1379500 BTU/h LPG

Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

First Stage

Security System

Relief Valve.

Maximum inlet pressure

80

Minimum inlet pressure

20.3

Outlet pressure

350 mbar

Nominal flow rate

2207200 BTU/h LPG

Brand

By Humcar

Connection Input

Quick Coupling Ø35 mm

Connection Output

3/8" Hose Coupling

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Not applicable.

Maximum inlet pressure

108.8

Minimum inlet pressure

10.2

Outlet pressure

28 mbar

Nominal flow rate

64792 BTU/h LPG

Brand

Humcar

Connection Input

5, M26 X 1

Connection Output

1/2" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

79.8

Minimum inlet pressure

20.3

Outlet pressure

28 mbar

Nominal flow rate

360450 BTU/h LPG

Cart
No products in the cart.
Notificaciones Judiciales
Email
WhatsApp
Phone
WhatsApp
Phone
Email
Notificaciones Judiciales
Select the fields to display
  • Image
  • Reference
  • Rating
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Additional Information
Click outside the comparison bar to close it.
Compare