High Pressure Regulator R150 Direct Acting First Stage LPG 10-30psi 1/2 "NPTh x 1/2 "NPTh 6500000 BTU/h LPG
High Pressure Regulator R150 Direct Acting First Stage LPG 10-30psi 1/2 "NPTh x 1/2 "NPTh 6500000 BTU/h LPG
External use regulator for commercial and industrial gas installations. Reference Standard NFPA-58, UL 144 and NTC-3873. With different flow rates according to the application and safety device.
External use regulator for commercial and industrial gas installations. Reference Standard NFPA-58, UL 144 and NTC-3873. With different flow rates according to the application and safety device.
Regulator for external use for residential and industrial gas installations. Reference Standard With different flow rates according to the application and safety device.
Regulator for external use for installations with portable LPG cylinders. Reference Standard NTC-3873 With different flow rates according to the application and safety device.
Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3727. With different flow rates according to the application and safety device relief valve.
Regulator for internal use for residential gas installations. Reference Standard NTC-3293. With different flow rates according to the application and safety device Proportional Shut-Off and Low Pressure Cut-Off at the inlet.
Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
Content
Inlet Pressure Min. 2 bar (29 psi). Max. inlet pressure 100 psi (6.9 bar). Output pressure range 10-30 psi . Flow rate 6.500.000 BTU/h LPG. Inlet connection 1/2" NPT h Outlet connection 1/2" NPT h.
Inlet Pressure MIN. 1 bar (14.5 psi). Inlet Pressure MAX. 4.2 bar (60.9 psi). Outlet Pressure mbar ("c.a.). Flow rate at inlet pressure
inlet pressure MIN Flow rate Kg/h LPG: 0. with set pressure Flow rate Kg/h LPG: . Inlet connection 3/4" NPT h Outlet connection 3/4" NPT h
Inlet Pressure MIN. 0.7 bar (10.2 psi). MAX Inlet Pressure. 7.5 bar (108.8 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate at inlet pressure
inlet pressure MIN Flow rate Kg/h LPG: 1.3. with set pressure Flow rate Kg/h LPG: . Inlet connection Quick coupling Ø35 mm Outlet connection Hose coupling 3/8".
Inlet Pressure MIN. 0.21 bar (3 psi). MAX Inlet Pressure 0.48 bar (7 psi). Outlet Pressure 100 mbar (40 "a.c.). Flow rate at inlet pressure
inlet pressure MIN. m³/ h GN 23. with set pressure m³/ h GN 35. Inlet connection 1 NPT h Outlet connection 1 NPT h
Inlet Pressure MIN. bar (3 psi). Inlet Pressure MAX. bar (10 psi). Outlet Pressure 50 mbar (20 "c.a.). Flow rate at inlet pressure
inlet pressure MIN. m³/ h GN 20. with set pressure m³/ h GN 19. Inlet connection 1/2" NPT h Outlet connection 1/2" NPT h
Inlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 5.52 bar (80 psi). Outlet Pressure 140 mbar (56 "w.c.). Flow rate at inlet pressure MIN Flow rate 44.2Kg/h LPG, at set pressure Flow rate 54.4Kg/h LPG. Inlet connection 1" NPT h Outlet connection 1" NPT h.
Additional Information
Brand
Humcar
Connection Input
1/2" NPT h
Connection Output
1/2" NPT h
Type of Adjustment
Adjustable
Stage
First Stage
Security System
Not applicable.
Maximum inlet pressure
100 psi
Minimum inlet pressure
29 psi
Outlet pressure
10 - 30 psi
Nominal flow rate
6,500,000 BTU/h LPG
Brand
Humcar
Connection Input
3/4" NPT h
Connection Output
3/4" NPT h
Type of Adjustment
Adjustable
Stage
First Stage
Security System
Not applicable.
Maximum inlet pressure
60.9
Minimum inlet pressure
14.5
Outlet pressure
0.5 - 12.4 psi
Nominal flow rate
215736 BTU/h LPG
Brand
By Humcar
Connection Input
Quick Coupling Ø35 mm
Connection Output
3/8" Hose Coupling
Type of Adjustment
Not Adjustable
Stage
Single Stage
Security System
Not applicable.
Maximum inlet pressure
108.8
Minimum inlet pressure
10.2
Outlet pressure
28 mbar
Nominal flow rate
64792 BTU/h LPG
Brand
Humcar
Connection Input
1 NPT h
Connection Output
1 NPT h
Type of Adjustment
Not Adjustable
Stage
Second Stage
Security System
Relief Valve.
Maximum inlet pressure
7
Minimum inlet pressure
3
Outlet pressure
100 mbar
Nominal flow rate
23 m³/ h GN
Brand
Humcar
Connection Input
1/2" NPT h
Connection Output
1/2" NPT h
Type of Adjustment
Not Adjustable
Stage
Second Stage
Security System
Proportional shut-off and low pressure cut-off at the inlet.
Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
Regulator for external use for residential installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.