Regulator ERG-S 25 90° Two Stage First Stage GN-GLP 340mbar G 3/4 JSC x G 1-1/4 JP
Regulator ERG-S 25 90° Two Stage First Stage GN-GLP 340mbar G 3/4 JSC x G 1-1/4 JP
Regulator for external use for residential, medium commercial and small industrial gas installations. Reference Standard EN 88-2 and EN 334 With different flow rates according to the application and safety device Relief Valve.
Regulator for external use for residential, medium commercial and small industrial gas installations. Reference Standard EN 88-2 and EN 334 With different flow rates according to the application and safety device Relief Valve.
Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
Regulator for internal use for residential gas installations. Reference Standard NTC-3293. With different flow rates according to the application and safety device Proportional Shut-Off and Low Pressure Cut-Off at the inlet.
Regulator for internal use for residential gas installations. Reference Standard NTC-3293. With different flow rates according to the application and safety device Proportional Shut-Off and Low Pressure Cut-Off at the inlet.
Regulator for external use for residential gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device.
Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
Content
Inlet Pressure Min. 1 bar (14.5 psi). Max. Inlet Pressure 6 bar (87 psi). Outlet Pressure 340 mbar (136 "c.a.). Connection Inlet G 3/4 JSC Connection Outlet G 1-1/4 JP
Inlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 5.52 bar (80 psi). Outlet Pressure 350 mbar (140 "w.c.). Flow rate with inlet pressure MIN Flow rate 44.2Kg/h LPG, with set pressure Flow rate 53.3Kg/h LPG. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT h.
Inlet Pressure MIN. bar (3 psi). Inlet Pressure MAX. bar (10 psi). Outlet Pressure 50 mbar (20 "c.a.). Flow rate at inlet pressure
inlet pressure MIN. m³/ h GN 20. with set pressure m³/ h GN 19. Inlet connection 1/2" NPT h Outlet connection 1/2" NPT h
Inlet Pressure MIN. bar (1.5 psi). Inlet Pressure MAX. bar (9.9 psi). Outlet Pressure 35 mbar (14 "w.c.). Flow rate at inlet pressure
inlet pressure MIN. m³/ h GN 12. with set pressure m³/ h GN 23. Inlet connection 1/2" NPT h Outlet connection 1/2" NPT h
Inlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 6.9 bar (100 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate with inlet pressure MIN Flow rate 17.3Kg/h LPG, with set pressure Flow rate 30Kg/h LPG. Inlet connection 1" NPT h Outlet connection 1" NPT h
Inlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 5.52 bar (80 psi). Outlet Pressure 140 mbar (56 "w.c.). Flow rate with inlet pressure MIN Flow rate Kg/h 44.2GLP, with set pressure Flow rate 54.4Kg/h GLP. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT h
Additional Information
Brand
ESKA
Connection Input
G 3/4" ISO 228 JSC
Connection Output
G 1-1/4" ISO 228 JP
Type of Adjustment
Not Adjustable
Stage
First Stage
Security System
low inlet pressure shut off, Relief Valve
Maximum inlet pressure
87 psi
Minimum inlet pressure
14.5 psi
Outlet pressure
340 mbar
Nominal flow rate
25 m³/ h NG, 28.9 Kg/h LPG
Brand
Humcar
Connection Input
3/4" NPT h
Connection Output
3/4" NPT h
Type of Adjustment
Not Adjustable
Stage
First Stage
Security System
Relief Valve.
Maximum inlet pressure
80
Minimum inlet pressure
20.3
Outlet pressure
350 mbar
Nominal flow rate
2207200 BTU/h LPG
Brand
Humcar
Connection Input
1/2" NPT h
Connection Output
1/2" NPT h
Type of Adjustment
Not Adjustable
Stage
Second Stage
Security System
Proportional shut-off and low pressure cut-off at the inlet.
Maximum inlet pressure
10
Minimum inlet pressure
3
Outlet pressure
50 mbar
Nominal flow rate
20 m³/ h GN
Brand
Humcar
Connection Input
1/2" NPT h
Connection Output
1/2" NPT h
Type of Adjustment
Not Adjustable
Stage
Second Stage
Security System
Proportional shut-off and low pressure cut-off at the inlet.
Regulator for external use for residential gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device.
Regulator for internal use for residential gas installations. Reference Standard NTC-3293. With different flow rates according to the application and safety device Proportional Shut-Off and Low Pressure Cut-Off at the inlet.
External use regulator for commercial and industrial gas installations. Reference Standard NFPA-58 and NTC-3873. With different flow rates according to the application and safety device.
Regulator for external use for residential gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.