• Home
  • Products
  • Regulator R10 Direct Acting Single Stage LPG 28 mbar 3/4" NPT h x 3/4" NPT h 863300 BTU/h LPG

Regulator R10 Direct Acting Single Stage LPG 28 mbar 3/4" NPT h x 3/4" NPT h 863300 BTU/h LPG

Regulator for external use for residential gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device.

Description

Inlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 6.9 bar (100 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate with inlet pressure MIN Flow rate 17.3Kg/h LPG. With set pressure Flow 30 Kg/h LPG. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT h

Additional information

Brand

Humcar

Connection Input

3/4" NPT h

Connection Output

3/4" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

100

Minimum inlet pressure

20.3

Outlet pressure

28 mbar

Nominal flow rate

863300 BTU/h LPG

Documents

Quick comparison

Regulator R10 Direct Acting Single Stage LPG 28 mbar 3/4" NPT h x 3/4" NPT h 863300 BTU/h LPG RemoveRegulator R4 Direct Acting Single Stage LPG 28 mbar M26 X 1.5 x 1/2" NPT h 360450 BTU/h LPG RemoveRegulator R10 Direct Acting First Stage LPG 350 mbar 3/4" NPT h x 3/4" NPT h 2207200 BTU/h LPG RemoveRegulator R50 Direct Acting Second Stage GN 21 mbar 1 NPT h x 1 NPT h 43 m³/ h GN RemoveHigh Pressure Regulator Direct Acting First Stage LPG 10 - 30 psi 1/2" NPT h x 1/2" NPT h 3365482 BTU/h LPG RemoveLow Pressure Cut-Off Regulator RCBP Self-Compensating Second Stage LPG 35 mbar 1/2" NPT h x 1/2" NPT h 1780000 BTU/h LPG Remove
NameRegulator R10 Direct Acting Single Stage LPG 28 mbar 3/4" NPT h x 3/4" NPT h 863300 BTU/h LPG RemoveRegulator R4 Direct Acting Single Stage LPG 28 mbar M26 X 1.5 x 1/2" NPT h 360450 BTU/h LPG RemoveRegulator R10 Direct Acting First Stage LPG 350 mbar 3/4" NPT h x 3/4" NPT h 2207200 BTU/h LPG RemoveRegulator R50 Direct Acting Second Stage GN 21 mbar 1 NPT h x 1 NPT h 43 m³/ h GN RemoveHigh Pressure Regulator Direct Acting First Stage LPG 10 - 30 psi 1/2" NPT h x 1/2" NPT h 3365482 BTU/h LPG RemoveLow Pressure Cut-Off Regulator RCBP Self-Compensating Second Stage LPG 35 mbar 1/2" NPT h x 1/2" NPT h 1780000 BTU/h LPG Remove
ImageRegulator R10 Direct Acting Single Stage LPG 28 mbar 3/4" NPT h x 3/4" NPT h 863300 BTU/h LPGRegulator R4 Direct Acting Single Stage LPG 28 mbar M26 X 1.5 x 1/2" NPT h 360450 BTU/h LPGRegulator R10 Direct Acting LPG First Stage 350 mbar 3/4" NPT h x 3/4" NPT h 2207200 BTU/h LPGRegulator R50 Direct Acting Second Stage GN 21 mbar 1 NPT h x 1 NPT h 43 m³/ h GNHigh Pressure Regulator Direct Acting First Stage LPG 10 - 30 psi 1/2" NPT h x 1/2" NPT h 3365482 BTU/h LPGLow Pressure Cut-Off Regulator RCBP Self-Compensating Second Stage LPG 35 mbar 1/2" NPT h x 1/2" NPT h 1780000 BTU/h LPG
Reference411267410818411257414054410200411507
Rating
Stock
Availability
Add to cart

Read more

Read more

Read more

Read more

Read more

Read more

DescriptionRegulator for external use for residential gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3727. With different flow rates according to the application and safety device relief valve.External use regulator for commercial and industrial gas installations. Reference Standard NFPA-58 and NTC-3873. With different flow rates according to the application and safety device.Regulator for internal use for residential gas installations. Reference Standard NTC-3293. With different flow rates according to the application and safety device Proportional Shut-Off and Low Pressure Cut-Off at the inlet.
ContentInlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 6.9 bar (100 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate with inlet pressure MIN Flow rate 17.3Kg/h LPG. With set pressure Flow 30 Kg/h LPG. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT hInlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 5.5 bar (79.8 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate with inlet pressure MIN Flow rate 7.2Kg/h LPG, with set pressure Flow rate 10.3Kg/h LPG. Inlet connection M26 X 1,5 Outlet connection 1/2" NPT h.Inlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 5.52 bar (80 psi). Outlet Pressure 350 mbar (140 "w.c.). Flow rate with inlet pressure MIN Flow rate 44.2Kg/h LPG, with set pressure Flow rate 53.3Kg/h LPG. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT h.Inlet Pressure MIN. 0.14 bar (2 psi). MAX Inlet Pressure 0.35 bar (5 psi). Outlet Pressure 21 mbar (8.4 "w.c.). Flow rate at inlet pressure inlet pressure MIN Flow rate Kg/h LPG: 0. with set pressure m³/ h GN 43. Inlet connection 1 NPT h Outlet connection 1 NPT hInlet Pressure Min. 2 bar (29 psi). Max. Inlet Pressure 100 psi (6.9 bar). Output Pressure 10 - 30 psi. Flow rate at inlet pressure Max. 3.365.482 BTU/h LPG. Inlet connection 1/2" NPT h Outlet connection 1/2" NPT h.Inlet Pressure MIN. 0.1 bar (1.5 psi). MAX Inlet Pressure 0.68 bar (9.9 psi). Outlet Pressure 35 mbar (14 "w.c.). Flow rate at inlet pressure inlet pressure MIN Flow rate Kg/h LPG: 0. with set pressure Flow rate Kg/h LPG: 35.7142857142857. Inlet connection 1/2" NPT h Outlet connection 1/2" NPT h
Additional Information
Brand

Humcar

Connection Input

3/4" NPT h

Connection Output

3/4" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

100

Minimum inlet pressure

20.3

Outlet pressure

28 mbar

Nominal flow rate

863300 BTU/h LPG

Brand

Humcar

Connection Input

5, M26 X 1

Connection Output

1/2" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

79.8

Minimum inlet pressure

20.3

Outlet pressure

28 mbar

Nominal flow rate

360450 BTU/h LPG

Brand

Humcar

Connection Input

3/4" NPT h

Connection Output

3/4" NPT h

Type of Adjustment

Not Adjustable

Stage

First Stage

Security System

Relief Valve.

Maximum inlet pressure

80

Minimum inlet pressure

20.3

Outlet pressure

350 mbar

Nominal flow rate

2207200 BTU/h LPG

Brand

Humcar

Connection Input

1 NPT h

Connection Output

1 NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Relief Valve.

Maximum inlet pressure

5

Minimum inlet pressure

2

Outlet pressure

21 mbar

Nominal flow rate

43 m³/ h GN

Brand

Humcar

Connection Input

1/2" NPT h

Connection Output

1/2" NPT h

Type of Adjustment

Adjustable

Stage

First Stage

Security System

Not applicable.

Maximum inlet pressure

100 psi

Minimum inlet pressure

29 psi

Outlet pressure

10 - 30 psi

Nominal flow rate

3365482 BTU/h LPG

Brand

Humcar

Connection Input

1/2" NPT h

Connection Output

1/2" NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Proportional shut-off and low pressure cut-off at the inlet.

Maximum inlet pressure

9.9

Minimum inlet pressure

1.5

Outlet pressure

35 mbar

Nominal flow rate

1780000 BTU/h LPG

Cart
No products in the cart.
Notificaciones Judiciales
Email
WhatsApp
Phone
WhatsApp
Phone
Email
Notificaciones Judiciales
Select the fields to display
  • Image
  • Reference
  • Rating
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Additional Information
Click outside the comparison bar to close it.
Compare