LPG Second Stage LPG Stabilizing Regulator 35 mbar 1/2" NPT h x 1/2" NPT h 979000 BTU/h LPG
LPG Second Stage LPG Stabilizing Regulator 35 mbar 1/2" NPT h x 1/2" NPT h 979000 BTU/h LPG
Regulator for internal use for residential and commercial gas installations. Reference Standard UNE-EN 88-1. With different flow rates according to the application and venting safety device that limits the
limits the performance flow.
Inlet Pressure MIN. 0.138 bar (2 psi). MAX Inlet Pressure 0.5 bar (7.25 psi). Outlet Pressure 35 mbar (14 "w.c.). Flow rate at inlet pressure MIN 97,900 BTU/h LPG . Inlet connection 1/2" NPT h Outlet connection 1/2" NPT h
Regulator for internal use for residential and commercial gas installations. Reference Standard UNE-EN 88-1. With different flow rates according to the application and safety venting device that limits the
limits the performance flow.
Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
External use regulator for residential and commercial gas installations. Reference Standard MX-032-X-SCFI-2013 and specification ES.02260.MX-CN. With different flow rates according to the application and safety device relief valve and low pressure cut-off (UPSO).
Regulator for external use for residential and industrial gas installations. Reference Standard With different flow rates according to the application and safety device.
Regulator for external use for residential and commercial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
External use regulator for commercial and industrial gas installations. Reference Standard NFPA-58 and NTC-3873. With different flow rates according to the application and safety device.
Content
Inlet Pressure MIN. 0.138 bar (2 psi). MAX Inlet Pressure 0.5 bar (7.25 psi). Outlet Pressure 35 mbar (14 "w.c.). Flow rate at inlet pressure MIN 97,900 BTU/h LPG . Inlet connection 1/2" NPT h Outlet connection 1/2" NPT h
Inlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 5.52 bar (80 psi). Outlet Pressure 350 mbar (140 "w.c.). Flow rate with inlet pressure MIN Flow rate 44.2Kg/h LPG, with set pressure Flow rate 53.3Kg/h LPG. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT h.
Inlet Pressure MIN. 1 bar (14.5 psi). Inlet Pressure MAX. 4 bar (58 psi). Outlet Pressure 21 mbar (8.4 "w.c.). Flow rate at inlet pressure
inlet pressure MIN Flow Kg/h LPG: 0. with set pressure m³/ h GN 10. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT h
Inlet Pressure MIN. 1 bar (14.5 psi). Inlet Pressure MAX. 4.2 bar (60.9 psi). Outlet Pressure mbar ("c.a.). Flow rate at inlet pressure
inlet pressure MIN Flow rate Kg/h LPG: 0. with set pressure Flow rate Kg/h LPG: . Inlet connection 3/4" NPT h Outlet connection 3/4" NPT h
Inlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 6.9 bar (100 psi). Outlet Pressure 15 psi (1034 mbar). Flow rate with inlet pressure MIN Flow rate 33.9 Kg/h LPG, with set pressure Flow rate 105.7 Kg/h LPG. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT h.
Inlet Pressure Min. 2 bar (29 psi). Max. Inlet Pressure 100 psi (6.9 bar). Output Pressure 10 - 30 psi. Flow rate at inlet pressure Max. 3.365.482 BTU/h LPG. Inlet connection 1/2" NPT h Outlet connection 1/2" NPT h.
Regulator for external use for residential installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3727. With different flow rates according to the application and safety device relief valve.
Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
Regulator for external use for residential and industrial gas installations. Reference Standard With different flow rates according to the application and safety device.