• Home
  • Products
  • Stabilizing Regulator Second Stage NG - LPG 114 mbar 1/2" NPT h x 1/2" NPT h 23 m³/ h NG - 1.323.181 BTU/h LPG

Stabilizing Regulator Second Stage NG - LPG 114 mbar 1/2" NPT h x 1/2" NPT h 23 m³/ h NG - 1.323.181 BTU/h LPG

Regulator for internal use for residential and commercial gas installations. Reference Standard UNE-EN 88-1. With different flow rates according to the application and venting safety device that limits the
limits the performance flow.

Description

Inlet Pressure MIN. 138mbar (2 psi). Inlet Pressure MAX. 500 mbar (7.25 psi). Outlet Pressure 114 mbar (45,6 "c.a.). Flow rate with setting inlet pressure 23 m³/ h NG - 1.323.181 BTU/h LPG . Inlet connection 1/2" NPT h Outlet connection 1/2" NPT h

Additional information

Brand

Humcar

Connection Input

1/2" NPT h

Connection Output

1/2" NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Proportional Closing.

Maximum inlet pressure

7.25

Minimum inlet pressure

2

Outlet pressure

114 mbar

Nominal flow rate

1.323.181 BTU/h LPG, 23 m³/ h NG

Documents

Quick comparison

Stabilizing Regulator Second Stage NG - LPG 114 mbar 1/2" NPT h x 1/2" NPT h 23 m³/ h NG - 1.323.181 BTU/h LPG RemoveRegulator R10 Direct Acting First Stage LPG 140 mbar 3/4" NPT h x 3/4" NPT h 2207200 BTU/h LPG RemoveRegulator R10 UPSO Direct Acting Single Stage GN 21 mbar 3/4" NPT h x 3/4" NPT h 10 m³/ h GN RemoveRegulator R101 Direct Acting Single Stage LPG 28 mbar M11 X 1 x 3/8" NPT h 72090 BTU/h LPG RemoveRegulator R10 Direct Acting First Stage LPG 15 psi 1" NPT h x 1" NPT h 1691000 BTU/h LPG RemoveRegulator R10 Direct Acting First Stage LPG 350 mbar 1" NPT h x 1" NPT h 2207200 BTU/h LPG Remove
NameStabilizing Regulator Second Stage NG - LPG 114 mbar 1/2" NPT h x 1/2" NPT h 23 m³/ h NG - 1.323.181 BTU/h LPG RemoveRegulator R10 Direct Acting First Stage LPG 140 mbar 3/4" NPT h x 3/4" NPT h 2207200 BTU/h LPG RemoveRegulator R10 UPSO Direct Acting Single Stage GN 21 mbar 3/4" NPT h x 3/4" NPT h 10 m³/ h GN RemoveRegulator R101 Direct Acting Single Stage LPG 28 mbar M11 X 1 x 3/8" NPT h 72090 BTU/h LPG RemoveRegulator R10 Direct Acting First Stage LPG 15 psi 1" NPT h x 1" NPT h 1691000 BTU/h LPG RemoveRegulator R10 Direct Acting First Stage LPG 350 mbar 1" NPT h x 1" NPT h 2207200 BTU/h LPG Remove
ImageStabilizing Regulator Second Stage NG - LPG 114 mbar 1/2" NPT h x 1/2" NPT h 23 m³/ h NG - 1.323.181 BTU/h LPGRegulator R10 Direct Acting First Stage LPG 140 mbar 3/4" NPT h x 3/4" NPT h 2207200 BTU/h LPGRegulator R10 UPSO Direct Acting Single Stage GN 21 mbar 3/4" NPT h x 3/4" NPT h 10 m³/ h GNRegulator R101 Direct Acting Single Stage LPG 28 mbar M11 X 1 x 3/8" NPT h 72090 BTU/h LPGRegulator R10 Direct Acting First Stage LPG 15 psi 1" NPT h x 1" NPT h 1691000 BTU/h LPGRegulator R10 Direct Acting First Stage LPG 350 mbar 1" NPT h x 1" NPT h 2207200 BTU/h LPG
Reference411513411259411206410880411262411258
Rating
Stock
Availability
Add to cart

Read more

Read more

Read more

Read more

Read more

Read more

DescriptionRegulator for internal use for residential and commercial gas installations. Reference Standard UNE-EN 88-1. With different flow rates according to the application and safety venting device that limits the limits the performance flow.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.External use regulator for residential and commercial gas installations. Reference Standard MX-032-X-SCFI-2013 and specification ES.02260.MX-CN. With different flow rates according to the application and safety device relief valve and low pressure cut-off (UPSO).Regulator for external use for residential gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential and commercial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
ContentInlet Pressure MIN. 138mbar (2 psi). Inlet Pressure MAX. 500 mbar (7.25 psi). Outlet Pressure 114 mbar (45,6 "c.a.). Flow rate with setting inlet pressure 23 m³/ h GN - 1.323.181 BTU/h GLP . Inlet connection 1/2" NPT h Outlet connection 1/2" NPT hInlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 5.52 bar (80 psi). Outlet Pressure 140 mbar (56 "w.c.). Flow rate with inlet pressure MIN Flow rate Kg/h 44.2GLP, with set pressure Flow rate 54.4Kg/h GLP. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT hInlet Pressure MIN. 1 bar (14.5 psi). Inlet Pressure MAX. 4 bar (58 psi). Outlet Pressure 21 mbar (8.4 "w.c.). Flow rate at inlet pressure inlet pressure MIN Flow Kg/h LPG: 0. with set pressure m³/ h GN 10. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT hInlet Pressure MIN. 0.7 bar (10.2 psi). MAX Inlet Pressure. 7 bar (100 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate with inlet pressure MIN Flow rate 1.4Kg/h LPG, with set pressure Flow rate 2.6Kg/h LPG. Connection Inlet M11 X 1 Connection Outlet 3/8" NPT hInlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 6.9 bar (100 psi). Outlet Pressure mbar 15 psi (1034 mbar). Flow rate at inlet pressure MIN Flow rate 33.9Kg/h LPG, at set pressure Flow rate 105.7Kg/h LPG . Inlet connection 1" NPT h Outlet connection 1" NPT h.Inlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 5.52 bar (80 psi). Outlet Pressure 350 mbar (140 "w.c.). Flow rate at inlet pressure MIN Flow rate 44.2Kg/h LPG, at set pressure Flow rate 53.3Kg/h LPG. Inlet connection 1" NPT h Outlet connection 1" NPT h.
Additional Information
Brand

Humcar

Connection Input

1/2" NPT h

Connection Output

1/2" NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Proportional Closing.

Maximum inlet pressure

7.25

Minimum inlet pressure

2

Outlet pressure

114 mbar

Nominal flow rate

1.323.181 BTU/h LPG, 23 m³/ h NG

Brand

Humcar

Connection Input

3/4" NPT h

Connection Output

3/4" NPT h

Type of Adjustment

Not Adjustable

Stage

First Stage

Security System

Relief Valve.

Maximum inlet pressure

80

Minimum inlet pressure

20.3

Outlet pressure

140 mbar

Nominal flow rate

2207200 BTU/h LPG

Brand

Humcar

Connection Input

3/4" NPT h

Connection Output

3/4" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

58

Minimum inlet pressure

14.5

Outlet pressure

21 mbar

Nominal flow rate

10 m³/ h GN

Brand

Humcar

Connection Input

M11 X 1

Connection Output

3/8" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

100

Minimum inlet pressure

10.2

Outlet pressure

28 mbar

Nominal flow rate

72090 BTU/h LPG

Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

First Stage

Security System

Relief Valve.

Maximum inlet pressure

100

Minimum inlet pressure

20.3

Outlet pressure

15 psi

Nominal flow rate

1691000 BTU/h LPG

Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

First Stage

Security System

Relief Valve.

Maximum inlet pressure

80

Minimum inlet pressure

20.3

Outlet pressure

350 mbar

Nominal flow rate

2207200 BTU/h LPG

Cart
No products in the cart.
Notificaciones Judiciales
Email
WhatsApp
Phone
WhatsApp
Phone
Email
Notificaciones Judiciales
Select the fields to display
  • Image
  • Reference
  • Rating
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Additional Information
Click outside the comparison bar to close it.
Compare