• Home
  • Products
  • Stabilizing Regulator Second Stage GN-GLP 138 mbar 3/4" NPT h x 3/4" NPT h 30m³/h GN - 34,6 Kg/h GLP

Stabilizing Regulator Second Stage GN-GLP 138 mbar 3/4" NPT h x 3/4" NPT h 30m³/h GN - 34,6 Kg/h GLP

Regulator for internal use for residential and commercial gas installations. Reference Standard UNE-EN 88-1. With different flow rates according to the application and venting safety device that limits the flow of
limits the flow of performance.

Description

Inlet Pressure MIN. 207 mbar (3 psi). MAX Inlet Pressure. 500 mbar (7.25 psi). Outlet Pressure 138 mbar (55,2 "c.a.). Flow rate at inlet pressure setting 30 m³/ h GN - 34,6 Kg/h LPG. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT h.

Additional information

Brand

Humcar

Connection Input

3/4" NPT h

Connection Output

3/4" NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Proportional Closing.

Maximum inlet pressure

7.25

Minimum inlet pressure

3

Outlet pressure

138 mbar

Nominal flow rate

(34,6 Kg/h LPG), 30 m³/ h GN

Documents

Quick comparison

Stabilizing Regulator Second Stage GN-GLP 138 mbar 3/4" NPT h x 3/4" NPT h 30m³/h GN - 34,6 Kg/h GLP RemoveRegulator R50 Direct Acting Single Stage LPG 28 mbar 1-1/4" NPT h x 1-1/4" NPT h 1379500 BTU/h LPG RemoveRegulator R50 Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 1379500 BTU/h LPG RemoveRegulator R10 Direct Acting First Stage LPG 15 psi 3/4" NPT h x 3/4" NPT h 1691000 BTU/h LPG RemoveRegulator R10 Direct Acting First Stage LPG 350 mbar 1" NPT h x 1" NPT h 2207200 BTU/h LPG RemoveLow Pressure Cut-Off Regulator RCBP Self-Compensating Second Stage GN 50 mbar 1/2" NPT h x 1/2" NPT h 20 m³/ h GN Remove
NameStabilizing Regulator Second Stage GN-GLP 138 mbar 3/4" NPT h x 3/4" NPT h 30m³/h GN - 34,6 Kg/h GLP RemoveRegulator R50 Direct Acting Single Stage LPG 28 mbar 1-1/4" NPT h x 1-1/4" NPT h 1379500 BTU/h LPG RemoveRegulator R50 Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 1379500 BTU/h LPG RemoveRegulator R10 Direct Acting First Stage LPG 15 psi 3/4" NPT h x 3/4" NPT h 1691000 BTU/h LPG RemoveRegulator R10 Direct Acting First Stage LPG 350 mbar 1" NPT h x 1" NPT h 2207200 BTU/h LPG RemoveLow Pressure Cut-Off Regulator RCBP Self-Compensating Second Stage GN 50 mbar 1/2" NPT h x 1/2" NPT h 20 m³/ h GN Remove
ImageStabilizing Regulator Second Stage GN-GLP 138 mbar 3/4" NPT h x 3/4" NPT h 30m³/h GN - 34,6 Kg/h GLPRegulator R50 Direct Acting Single Stage LPG 28 mbar 1-1/4" NPT h x 1-1/4" NPT h 1379500 BTU/h LPGRegulator R50 Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 1379500 BTU/h LPGRegulator R10 Direct Acting First Stage LPG 15 psi 3/4" NPT h x 3/4" NPT h 1691000 BTU/h LPGRegulator R10 Direct Acting First Stage LPG 350 mbar 1" NPT h x 1" NPT h 2207200 BTU/h LPGLow Pressure Cut-Off Regulator RCBP Self-Compensating Second Stage GN 50 mbar 1/2" NPT h x 1/2" NPT h 20 m³/ h GN
Reference411525414002414001411261411258411518
Rating
Stock
Availability
Add to cart

Read more

Read more

Read more

Read more

Read more

Read more

DescriptionRegulator for internal use for residential and commercial gas installations. Reference Standard UNE-EN 88-1. With different flow rates according to the application and venting safety device that limits the flow of limits the flow of performance.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential and commercial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for internal use for residential gas installations. Reference Standard NTC-3293. With different flow rates according to the application and safety device Proportional Shut-Off and Low Pressure Cut-Off at the inlet.
ContentInlet Pressure MIN. 207 mbar (3 psi). MAX Inlet Pressure. 500 mbar (7.25 psi). Outlet Pressure 138 mbar (55,2 "c.a.). Flow rate at inlet pressure setting 30 m³/ h GN - 34,6 Kg/h LPG. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT h.Inlet Pressure MIN. 0.7 bar (10.2 psi). MAX Inlet Pressure. 5.52 bar (80 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate with inlet pressure MIN 27.6Kg/h LPG, with set pressure Flow rate 84.8Kg/h LPG. Connection Inlet 1-1/4" NPT h Connection Outlet 1-1/4" NPT h.Inlet Pressure MIN. 0.7 bar (10.2 psi). MAX Inlet Pressure. 5.52 bar (80 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate at inlet pressure MIN Flow rate 27.6Kg/h LPG, at set pressure Flow rate 84.8Kg/h LPG. Inlet connection 1" NPT h Outlet connection 1" NPT h.Inlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 6.9 bar (100 psi). Outlet Pressure 15 psi (1034 mbar). Flow rate with inlet pressure MIN Flow rate 33.9 Kg/h LPG, with set pressure Flow rate 105.7 Kg/h LPG. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT h.Inlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 5.52 bar (80 psi). Outlet Pressure 350 mbar (140 "w.c.). Flow rate at inlet pressure MIN Flow rate 44.2Kg/h LPG, at set pressure Flow rate 53.3Kg/h LPG. Inlet connection 1" NPT h Outlet connection 1" NPT h.Inlet Pressure MIN. bar (3 psi). Inlet Pressure MAX. bar (10 psi). Outlet Pressure 50 mbar (20 "c.a.). Flow rate at inlet pressure inlet pressure MIN. m³/ h GN 20. with set pressure m³/ h GN 19. Inlet connection 1/2" NPT h Outlet connection 1/2" NPT h
Additional Information
Brand

Humcar

Connection Input

3/4" NPT h

Connection Output

3/4" NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Proportional Closing.

Maximum inlet pressure

7.25

Minimum inlet pressure

3

Outlet pressure

138 mbar

Nominal flow rate

(34,6 Kg/h LPG), 30 m³/ h GN

Brand

Humcar

Connection Input

1-1/4" NPT h

Connection Output

1-1/4" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

80

Minimum inlet pressure

10.2

Outlet pressure

28 mbar

Nominal flow rate

1379500 BTU/h LPG

Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

80

Minimum inlet pressure

10.2

Outlet pressure

28 mbar

Nominal flow rate

1379500 BTU/h LPG

Brand

Humcar

Connection Input

3/4" NPT h

Connection Output

3/4" NPT h

Type of Adjustment

Not Adjustable

Stage

First Stage

Security System

Relief Valve.

Maximum inlet pressure

100

Minimum inlet pressure

20.3

Outlet pressure

15 psi

Nominal flow rate

1691000 BTU/h LPG

Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

First Stage

Security System

Relief Valve.

Maximum inlet pressure

80

Minimum inlet pressure

20.3

Outlet pressure

350 mbar

Nominal flow rate

2207200 BTU/h LPG

Brand

Humcar

Connection Input

1/2" NPT h

Connection Output

1/2" NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Proportional shut-off and low pressure cut-off at the inlet.

Maximum inlet pressure

10

Minimum inlet pressure

3

Outlet pressure

50 mbar

Nominal flow rate

20 m³/ h GN

Cart
No products in the cart.
Notificaciones Judiciales
Email
WhatsApp
Phone
WhatsApp
Phone
Email
Notificaciones Judiciales
Select the fields to display
  • Image
  • Reference
  • Rating
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Additional Information
Click outside the comparison bar to close it.
Compare