• Home
  • Products
  • Stabilizing Regulator Second Stage GN 23 mbar 1/2" NPT h x 1/2" NPT h 10 m³/ h GN

Stabilizing Regulator Second Stage GN 23 mbar 1/2" NPT h x 1/2" NPT h 10 m³/ h GN

Regulator for internal use for residential and commercial gas installations. Reference Standard UNE-EN 88-1. With different flow rates according to the application and venting safety device that limits the
limits the performance flow.

Description

Inlet Pressure MIN. 138 mbar (2 psi). MAX Inlet Pressure. 500 mbar (7.25 psi). Outlet Pressure 23 mbar (9.2 "c.a.). Flow rate at inlet pressure setting 10 m³/ h GN. Inlet connection 1/2" NPT h Outlet connection 1/2" NPT h

Additional information

Brand

Humcar

Connection Input

1/2" NPT h

Connection Output

1/2" NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Proportional Closing.

Maximum inlet pressure

7.25

Minimum inlet pressure

2

Outlet pressure

23 mbar

Nominal flow rate

10 m³/ h GN

Documents

Quick comparison

Second Stage Stabilizing Regulator GN 23 mbar 1/2" NPT h x 1/2" NPT h 10 m³/ h GN RemoveRegulator R50 Direct Acting Second Stage GN 100 mbar 1 NPT h x 1 NPT h 23 m³/ h GN RemoveR7 Regulator Direct Acting Single Stage LPG 28mbar 3/4 "NPTh x 3/4 "NPTh 431650BTU/h LPG RemoveRegulator R10 Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 863300 BTU/h LPG RemoveLow Pressure Cut-Off Regulator RCBP Self-Compensating Second Stage GN 35 mbar 1/2" NPT h x 1/2" NPT h 12 m³/ h GN RemoveHigh Pressure Regulator Direct Acting First Stage LPG 10 - 30 psi 1/2" NPT h x 1/2" NPT h 3365482 BTU/h LPG Remove
NameSecond Stage Stabilizing Regulator GN 23 mbar 1/2" NPT h x 1/2" NPT h 10 m³/ h GN RemoveRegulator R50 Direct Acting Second Stage GN 100 mbar 1 NPT h x 1 NPT h 23 m³/ h GN RemoveR7 Regulator Direct Acting Single Stage LPG 28mbar 3/4 "NPTh x 3/4 "NPTh 431650BTU/h LPG RemoveRegulator R10 Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 863300 BTU/h LPG RemoveLow Pressure Cut-Off Regulator RCBP Self-Compensating Second Stage GN 35 mbar 1/2" NPT h x 1/2" NPT h 12 m³/ h GN RemoveHigh Pressure Regulator Direct Acting First Stage LPG 10 - 30 psi 1/2" NPT h x 1/2" NPT h 3365482 BTU/h LPG Remove
ImageStabilizing Regulator Second Stage GN 23 mbar 1/2" NPT h x 1/2" NPT h 10 m³/ h GNRegulator R50 Direct Acting Second Stage GN 100 mbar 1 NPT h x 1 NPT h 23 m³/ h GNR7 Regulator Direct Acting Single Stage LPG 28mbar 3/4 "NPTh x 3/4 "NPTh 431650BTU/h LPGRegulator R10 Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 863300 BTU/h LPGLow Pressure Cut-Off Regulator RCBP Self-Compensating Second Stage GN 35 mbar 1/2" NPT h x 1/2" NPT h 12 m³/ h GNHigh Pressure Regulator Direct Acting First Stage LPG 10 - 30 psi 1/2" NPT h x 1/2" NPT h 3365482 BTU/h LPG
Reference411510414018411022411268411504410200
Rating
Stock
Availability
Add to cart

Read more

Read more

Read more

Read more

Read more

Read more

DescriptionRegulator for internal use for residential and commercial gas installations. Reference Standard UNE-EN 88-1. With different flow rates according to the application and safety venting device that limits the limits the performance flow.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3727. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device.Regulator for internal use for residential gas installations. Reference Standard NTC-3293. With different flow rates according to the application and safety device Proportional Shut-Off and Low Pressure Cut-Off at the inlet.External use regulator for commercial and industrial gas installations. Reference Standard NFPA-58 and NTC-3873. With different flow rates according to the application and safety device.
ContentInlet Pressure MIN. 138 mbar (2 psi). MAX Inlet Pressure. 500 mbar (7.25 psi). Outlet Pressure 23 mbar (9.2 "c.a.). Flow rate at inlet pressure setting 10 m³/ h GN. Inlet connection 1/2" NPT h Outlet connection 1/2" NPT hInlet Pressure MIN. 0.21 bar (3 psi). MAX Inlet Pressure 0.48 bar (7 psi). Outlet Pressure 100 mbar (40 "a.c.). Flow rate at inlet pressure inlet pressure MIN. m³/ h GN 23. with set pressure m³/ h GN 35. Inlet connection 1 NPT h Outlet connection 1 NPT hInlet pressure min. 1 bar (14.5 psi). Max. inlet pressure 6.9 bar (100 psi). Outlet Pressure 28 mbar (11.2 "c.a.). Flow rate at min. inlet pressure Flow rate 8.6Kg/h LPG (431,650 BTU/h LPG), at set pressure Flow rate 26.5Kg/h LPG (1,323,430 BTU/h LPG). Inlet connection 3/4" NPTh Inlet connection 3/4" NPTh Outlet connection.Inlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 6.9 bar (100 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate with inlet pressure MIN Flow rate 17.3Kg/h LPG, with set pressure Flow rate 30Kg/h LPG. Inlet connection 1" NPT h Outlet connection 1" NPT hInlet Pressure MIN. bar (1.5 psi). Inlet Pressure MAX. bar (9.9 psi). Outlet Pressure 35 mbar (14 "w.c.). Flow rate at inlet pressure inlet pressure MIN. m³/ h GN 12. with set pressure m³/ h GN 23. Inlet connection 1/2" NPT h Outlet connection 1/2" NPT hInlet Pressure Min. 2 bar (29 psi). Max. Inlet Pressure 100 psi (6.9 bar). Output Pressure 10 - 30 psi. Flow rate at inlet pressure Max. 3.365.482 BTU/h LPG. Inlet connection 1/2" NPT h Outlet connection 1/2" NPT h.
Additional Information
Brand

Humcar

Connection Input

1/2" NPT h

Connection Output

1/2" NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Proportional Closing.

Maximum inlet pressure

7.25

Minimum inlet pressure

2

Outlet pressure

23 mbar

Nominal flow rate

10 m³/ h GN

Brand

Humcar

Connection Input

1 NPT h

Connection Output

1 NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Relief Valve.

Maximum inlet pressure

7

Minimum inlet pressure

3

Outlet pressure

100 mbar

Nominal flow rate

23 m³/ h GN

Brand

Humcar

Connection Input

3/4" NPT h

Connection Output

3/4" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

100 psi

Minimum inlet pressure

14.5 psi

Outlet pressure

28 mbar

Nominal flow rate

431650 BTU/h LPG

Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

100

Minimum inlet pressure

20.3

Outlet pressure

28 mbar

Nominal flow rate

863300 BTU/h LPG

Brand

Humcar

Connection Input

1/2" NPT h

Connection Output

1/2" NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Proportional shut-off and low pressure cut-off at the inlet.

Maximum inlet pressure

9.9

Minimum inlet pressure

1.5

Outlet pressure

35 mbar

Nominal flow rate

12 m³/ h GN

Brand

Humcar

Connection Input

1/2" NPT h

Connection Output

1/2" NPT h

Type of Adjustment

Adjustable

Stage

First Stage

Security System

Not applicable.

Maximum inlet pressure

100 psi

Minimum inlet pressure

29 psi

Outlet pressure

10 - 30 psi

Nominal flow rate

3365482 BTU/h LPG

Cart
No products in the cart.
Notificaciones Judiciales
Email
WhatsApp
Phone
WhatsApp
Phone
Email
Notificaciones Judiciales
Select the fields to display
  • Image
  • Reference
  • Rating
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Additional Information
Click outside the comparison bar to close it.
Compare