• Home
  • Products
  • Regulator OPSO Direct Acting First Stage GN 350 mbar 1" NPT h x 1" NPT h 12 m³/ h GN

Regulator OPSO Direct Acting First Stage GN 350 mbar 1" NPT h x 1" NPT h 12 m³/ h GN

Regulator for internal use for residential and commercial gas installations. Reference Standard With different flow rates according to the application and overpressure cut-off safety device.

Description

Inlet Pressure MIN. 1 bar (14.5 psi). MAX Inlet Pressure 10 bar (145 psi). Outlet Pressure 350 mbar ("c.a.). Flow rate at inlet pressure
inlet pressure MIN. m³/ h GN 12. with set pressure m³/ h GN 62. Inlet connection 1" NPT h Outlet connection 1" NPT h

Additional information

Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

First Stage

Security System

Overpressure cutting.

Maximum inlet pressure

145

Minimum inlet pressure

14.5

Outlet pressure

350 mbar

Nominal flow rate

12 m³/ h GN

Documents

Quick comparison

Regulator OPSO Direct Acting First Stage GN 350 mbar 1" NPT h x 1" NPT h 12 m³/ h GN RemoveR7 Regulator Direct Acting Single Stage LPG 28mbar 3/4 "NPTh x 3/4 "NPTh 431650BTU/h LPG RemoveHigh Pressure Regulator Direct Acting First Stage LPG 10 - 30 psi 1/2" NPT h x 1/2" NPT h 3365482 BTU/h LPG RemoveRegulator R101 Direct Acting Single Stage LPG 28 mbar M11 X 1 x 3/8" NPT h 72090 BTU/h LPG RemoveRegulator R50 Direct Acting Second Stage GN 21 mbar 1 NPT h x 1 NPT h 43 m³/ h GN RemoveRegulator R50 Direct Acting Second Stage GN 100 mbar 1 NPT h x 1 NPT h 23 m³/ h GN Remove
NameRegulator OPSO Direct Acting First Stage GN 350 mbar 1" NPT h x 1" NPT h 12 m³/ h GN RemoveR7 Regulator Direct Acting Single Stage LPG 28mbar 3/4 "NPTh x 3/4 "NPTh 431650BTU/h LPG RemoveHigh Pressure Regulator Direct Acting First Stage LPG 10 - 30 psi 1/2" NPT h x 1/2" NPT h 3365482 BTU/h LPG RemoveRegulator R101 Direct Acting Single Stage LPG 28 mbar M11 X 1 x 3/8" NPT h 72090 BTU/h LPG RemoveRegulator R50 Direct Acting Second Stage GN 21 mbar 1 NPT h x 1 NPT h 43 m³/ h GN RemoveRegulator R50 Direct Acting Second Stage GN 100 mbar 1 NPT h x 1 NPT h 23 m³/ h GN Remove
ImageRegulator OPSO Direct Acting First Stage GN 350 mbar 1" NPT h x 1" NPT h 12 m³/ h GNR7 Regulator Direct Acting Single Stage LPG 28mbar 3/4 "NPTh x 3/4 "NPTh 431650BTU/h LPGHigh Pressure Regulator Direct Acting First Stage LPG 10 - 30 psi 1/2" NPT h x 1/2" NPT h 3365482 BTU/h LPGRegulator R101 Direct Acting Single Stage LPG 28 mbar M11 X 1 x 3/8" NPT h 72090 BTU/h LPGRegulator R50 Direct Acting Second Stage GN 21 mbar 1 NPT h x 1 NPT h 43 m³/ h GNRegulator R50 Direct Acting Second Stage GN 100 mbar 1 NPT h x 1 NPT h 23 m³/ h GN
Reference411720411022410200410880414054414018
Rating
Stock
Availability
Add to cart

Read more

Read more

Read more

Read more

Read more

Read more

DescriptionRegulator for internal use for residential and commercial gas installations. Reference Standard With different flow rates according to the application and overpressure cut-off safety device.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.External use regulator for commercial and industrial gas installations. Reference Standard NFPA-58 and NTC-3873. With different flow rates according to the application and safety device.Regulator for external use for residential gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3727. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3727. With different flow rates according to the application and safety device relief valve.
ContentInlet Pressure MIN. 1 bar (14.5 psi). MAX Inlet Pressure 10 bar (145 psi). Outlet Pressure 350 mbar ("c.a.). Flow rate at inlet pressure inlet pressure MIN. m³/ h GN 12. with set pressure m³/ h GN 62. Inlet connection 1" NPT h Outlet connection 1" NPT hInlet pressure min. 1 bar (14.5 psi). Max. inlet pressure 6.9 bar (100 psi). Outlet Pressure 28 mbar (11.2 "c.a.). Flow rate at min. inlet pressure Flow rate 8.6Kg/h LPG (431,650 BTU/h LPG), at set pressure Flow rate 26.5Kg/h LPG (1,323,430 BTU/h LPG). Inlet connection 3/4" NPTh Inlet connection 3/4" NPTh Outlet connection.Inlet Pressure Min. 2 bar (29 psi). Max. Inlet Pressure 100 psi (6.9 bar). Output Pressure 10 - 30 psi. Flow rate at inlet pressure Max. 3.365.482 BTU/h LPG. Inlet connection 1/2" NPT h Outlet connection 1/2" NPT h.Inlet Pressure MIN. 0.7 bar (10.2 psi). MAX Inlet Pressure. 7 bar (100 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate with inlet pressure MIN Flow rate 1.4Kg/h LPG, with set pressure Flow rate 2.6Kg/h LPG. Connection Inlet M11 X 1 Connection Outlet 3/8" NPT hInlet Pressure MIN. 0.14 bar (2 psi). MAX Inlet Pressure 0.35 bar (5 psi). Outlet Pressure 21 mbar (8.4 "w.c.). Flow rate at inlet pressure inlet pressure MIN Flow rate Kg/h LPG: 0. with set pressure m³/ h GN 43. Inlet connection 1 NPT h Outlet connection 1 NPT hInlet Pressure MIN. 0.21 bar (3 psi). MAX Inlet Pressure 0.48 bar (7 psi). Outlet Pressure 100 mbar (40 "a.c.). Flow rate at inlet pressure inlet pressure MIN. m³/ h GN 23. with set pressure m³/ h GN 35. Inlet connection 1 NPT h Outlet connection 1 NPT h
Additional Information
Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

First Stage

Security System

Overpressure cutting.

Maximum inlet pressure

145

Minimum inlet pressure

14.5

Outlet pressure

350 mbar

Nominal flow rate

12 m³/ h GN

Brand

Humcar

Connection Input

3/4" NPT h

Connection Output

3/4" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

100 psi

Minimum inlet pressure

14.5 psi

Outlet pressure

28 mbar

Nominal flow rate

431650 BTU/h LPG

Brand

Humcar

Connection Input

1/2" NPT h

Connection Output

1/2" NPT h

Type of Adjustment

Adjustable

Stage

First Stage

Security System

Not applicable.

Maximum inlet pressure

100 psi

Minimum inlet pressure

29 psi

Outlet pressure

10 - 30 psi

Nominal flow rate

3365482 BTU/h LPG

Brand

Humcar

Connection Input

M11 X 1

Connection Output

3/8" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

100

Minimum inlet pressure

10.2

Outlet pressure

28 mbar

Nominal flow rate

72090 BTU/h LPG

Brand

Humcar

Connection Input

1 NPT h

Connection Output

1 NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Relief Valve.

Maximum inlet pressure

5

Minimum inlet pressure

2

Outlet pressure

21 mbar

Nominal flow rate

43 m³/ h GN

Brand

Humcar

Connection Input

1 NPT h

Connection Output

1 NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Relief Valve.

Maximum inlet pressure

7

Minimum inlet pressure

3

Outlet pressure

100 mbar

Nominal flow rate

23 m³/ h GN

Cart
No products in the cart.
Notificaciones Judiciales
Email
WhatsApp
Phone
WhatsApp
Phone
Email
Notificaciones Judiciales
Select the fields to display
  • Image
  • Reference
  • Rating
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Additional Information
Click outside the comparison bar to close it.
Compare