• Home
  • Products
  • Regulator OPSO Direct Acting First Stage GN 350 mbar 3/4" NPT h x 3/4" NPT h 25 m³/ h GN

Regulator OPSO Direct Acting First Stage GN 350 mbar 3/4" NPT h x 3/4" NPT h 25 m³/ h GN

Regulator for internal use for residential and commercial gas installations. Reference Standard ES.02260.MX-CN under standard
MX-032-X-SCFI-2013 With different flow rates according to the application and safety device Overpressure Cut-Off.

Description

Inlet Pressure MIN. 1 bar (14.5 psi). MAX Inlet Pressure. 4 bar (58 psi). Outlet Pressure 350 mbar ("c.a.). Flow rate at inlet pressure
inlet pressure MIN m³/ h GN 17.2. with set pressure m³/ h GN 25. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT h

Additional information

Brand

Humcar

Connection Input

3/4" NPT h

Connection Output

3/4" NPT h

Type of Adjustment

Not Adjustable

Stage

First Stage

Security System

Overpressure cutting.

Maximum inlet pressure

58

Minimum inlet pressure

14.5

Outlet pressure

350 mbar

Nominal flow rate

25 m³/ h GN

Documents

Quick comparison

Regulator OPSO Direct Acting First Stage GN 350 mbar 3/4" NPT h x 3/4" NPT h 25 m³/ h GN RemoveRegulator R10 Direct Acting Single Stage LPG 28 mbar 3/4" NPT h x 3/4" NPT h 863300 BTU/h LPG RemoveHigh Pressure Regulator Direct Acting First Stage LPG 10 - 30 psi 1/2" NPT h x 1/2" NPT h 3365482 BTU/h LPG RemoveLow Pressure Cut-Off Regulator RCBP Self-Compensating Second Stage GN 35 mbar 1/2" NPT h x 1/2" NPT h 12 m³/ h GN RemoveRegulator R10 UPSO Direct Acting Single Stage GN 21 mbar 3/4" NPT h x 3/4" NPT h 10 m³/ h GN RemoveRegulator R10 RVI Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 768960 BTU/h LPG Remove
NameRegulator OPSO Direct Acting First Stage GN 350 mbar 3/4" NPT h x 3/4" NPT h 25 m³/ h GN RemoveRegulator R10 Direct Acting Single Stage LPG 28 mbar 3/4" NPT h x 3/4" NPT h 863300 BTU/h LPG RemoveHigh Pressure Regulator Direct Acting First Stage LPG 10 - 30 psi 1/2" NPT h x 1/2" NPT h 3365482 BTU/h LPG RemoveLow Pressure Cut-Off Regulator RCBP Self-Compensating Second Stage GN 35 mbar 1/2" NPT h x 1/2" NPT h 12 m³/ h GN RemoveRegulator R10 UPSO Direct Acting Single Stage GN 21 mbar 3/4" NPT h x 3/4" NPT h 10 m³/ h GN RemoveRegulator R10 RVI Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 768960 BTU/h LPG Remove
ImageRegulator OPSO Direct Acting First Stage GN 350 mbar 3/4" NPT h x 3/4" NPT h 25 m³/ h GNRegulator R10 Direct Acting Single Stage LPG 28 mbar 3/4" NPT h x 3/4" NPT h 863300 BTU/h LPGHigh Pressure Regulator Direct Acting First Stage LPG 10 - 30 psi 1/2" NPT h x 1/2" NPT h 3365482 BTU/h LPGLow Pressure Cut-Off Regulator RCBP Self-Compensating Second Stage GN 35 mbar 1/2" NPT h x 1/2" NPT h 12 m³/ h GNRegulator R10 UPSO Direct Acting Single Stage GN 21 mbar 3/4" NPT h x 3/4" NPT h 10 m³/ h GNRegulator R10 RVI Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 768960 BTU/h LPG
Reference411729411267410200411504411206411245
Rating
Stock
Availability
Add to cart

Read more

Read more

Read more

Read more

Read more

Read more

DescriptionRegulator for internal use for residential and commercial gas installations. Reference Standard ES.02260.MX-CN under norm MX-032-X-SCFI-2013 With different flow rates according to the application and safety device Overpressure Cut-Off.Regulator for external use for residential gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device.External use regulator for commercial and industrial gas installations. Reference Standard NFPA-58 and NTC-3873. With different flow rates according to the application and safety device.Regulator for internal use for residential gas installations. Reference Standard NTC-3293. With different flow rates according to the application and safety device Proportional Shut-Off and Low Pressure Cut-Off at the inlet.External use regulator for residential and commercial gas installations. Reference Standard MX-032-X-SCFI-2013 and specification ES.02260.MX-CN. With different flow rates according to the application and safety device relief valve and low pressure cut-off (UPSO).Regulator for external use for residential installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
ContentInlet Pressure MIN. 1 bar (14.5 psi). MAX Inlet Pressure. 4 bar (58 psi). Outlet Pressure 350 mbar ("c.a.). Flow rate at inlet pressure inlet pressure MIN m³/ h GN 17.2. with set pressure m³/ h GN 25. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT hInlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 6.9 bar (100 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate with inlet pressure MIN Flow rate 17.3Kg/h LPG. With set pressure Flow 30 Kg/h LPG. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT hInlet Pressure Min. 2 bar (29 psi). Max. Inlet Pressure 100 psi (6.9 bar). Output Pressure 10 - 30 psi. Flow rate at inlet pressure Max. 3.365.482 BTU/h LPG. Inlet connection 1/2" NPT h Outlet connection 1/2" NPT h.Inlet Pressure MIN. bar (1.5 psi). Inlet Pressure MAX. bar (9.9 psi). Outlet Pressure 35 mbar (14 "w.c.). Flow rate at inlet pressure inlet pressure MIN. m³/ h GN 12. with set pressure m³/ h GN 23. Inlet connection 1/2" NPT h Outlet connection 1/2" NPT hInlet Pressure MIN. 1 bar (14.5 psi). Inlet Pressure MAX. 4 bar (58 psi). Outlet Pressure 21 mbar (8.4 "w.c.). Flow rate at inlet pressure inlet pressure MIN Flow Kg/h LPG: 0. with set pressure m³/ h GN 10. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT hInlet Pressure MIN. 1.04 bar (15.1 psi). MAX Inlet Pressure. 6.9 bar (100 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate at inlet pressure MIN Flow rate 15.4Kg/h LPG, at set pressure Flow rate 22.1Kg/h LPG. Connection Inlet 1" NPT h Connection Outlet 1" NPT h
Additional Information
Brand

Humcar

Connection Input

3/4" NPT h

Connection Output

3/4" NPT h

Type of Adjustment

Not Adjustable

Stage

First Stage

Security System

Overpressure cutting.

Maximum inlet pressure

58

Minimum inlet pressure

14.5

Outlet pressure

350 mbar

Nominal flow rate

25 m³/ h GN

Brand

Humcar

Connection Input

3/4" NPT h

Connection Output

3/4" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

100

Minimum inlet pressure

20.3

Outlet pressure

28 mbar

Nominal flow rate

863300 BTU/h LPG

Brand

Humcar

Connection Input

1/2" NPT h

Connection Output

1/2" NPT h

Type of Adjustment

Adjustable

Stage

First Stage

Security System

Not applicable.

Maximum inlet pressure

100 psi

Minimum inlet pressure

29 psi

Outlet pressure

10 - 30 psi

Nominal flow rate

3365482 BTU/h LPG

Brand

Humcar

Connection Input

1/2" NPT h

Connection Output

1/2" NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Proportional shut-off and low pressure cut-off at the inlet.

Maximum inlet pressure

9.9

Minimum inlet pressure

1.5

Outlet pressure

35 mbar

Nominal flow rate

12 m³/ h GN

Brand

Humcar

Connection Input

3/4" NPT h

Connection Output

3/4" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

58

Minimum inlet pressure

14.5

Outlet pressure

21 mbar

Nominal flow rate

10 m³/ h GN

Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

100

Minimum inlet pressure

15.1

Outlet pressure

28 mbar

Nominal flow rate

768960 BTU/h LPG

Cart
No products in the cart.
Notificaciones Judiciales
Email
WhatsApp
Phone
WhatsApp
Phone
Email
Notificaciones Judiciales
Select the fields to display
  • Image
  • Reference
  • Rating
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Additional Information
Click outside the comparison bar to close it.
Compare