External use regulator for residential gas installations. Manufactured under NTC-3727 standard. With different flow rates according to the application and safety device relief valve.

Description

Inlet Pressure Min. 30 psi (2.07 bar). Max. Inlet Pressure 4.14 bar (60 psi). Outlet Pressure 20 mbar (8 "c.a.). Flow rate at inlet pressure Min. 3,2 m³/ h GN. With set pressure 4,5 m³/ h GN. External Inlet Connection M26 x1.5 Male Internal 1/4" NPT h Outlet Connection 3/8" NPT h.

Additional information

Brand

Humcar

Connection Input

External M26 x1.5 Male Internal 1/4" NPT h

Connection Output

3/8" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

60 psi

Minimum inlet pressure

30 psi

Outlet pressure

20 mbar

Max. flow rate

3.2 m³/h GN

Nominal flow rate

4.5 m³/h GN

Documents

Quick comparison

Regulador R204 Acción Directa Única Etapa GN 20 mbar Externa M26 x1.5m Interna 1/4" NPT h x 3/8” NPT h 3.2 m³/ h GN RemoverRegulator R4 Direct Acting Single Stage LPG 28 mbar M26 X 1.5 x 1/2" NPT h 360450 BTU/h LPG RemoveRegulator R10 Direct Acting Single Stage LPG 28 mbar 3/4" NPT h x 3/4" NPT h 863300 BTU/h LPG RemoveLow Pressure Cut-Off Regulator RCBP Self-Compensating Second Stage GN 35 mbar 1/2" NPT h x 1/2" NPT h 12 m³/ h GN RemoveRegulator R10 Direct Acting First Stage LPG 15 psi 1" NPT h x 1" NPT h 1691000 BTU/h LPG RemoveRegulator R10 Direct Acting First Stage LPG 140 mbar 1" NPT h x 1" NPT h 2207200 BTU/h LPG Remove
NameRegulador R204 Acción Directa Única Etapa GN 20 mbar Externa M26 x1.5m Interna 1/4" NPT h x 3/8” NPT h 3.2 m³/ h GN RemoverRegulator R4 Direct Acting Single Stage LPG 28 mbar M26 X 1.5 x 1/2" NPT h 360450 BTU/h LPG RemoveRegulator R10 Direct Acting Single Stage LPG 28 mbar 3/4" NPT h x 3/4" NPT h 863300 BTU/h LPG RemoveLow Pressure Cut-Off Regulator RCBP Self-Compensating Second Stage GN 35 mbar 1/2" NPT h x 1/2" NPT h 12 m³/ h GN RemoveRegulator R10 Direct Acting First Stage LPG 15 psi 1" NPT h x 1" NPT h 1691000 BTU/h LPG RemoveRegulator R10 Direct Acting First Stage LPG 140 mbar 1" NPT h x 1" NPT h 2207200 BTU/h LPG Remove
ImageRegulador R204  Acción Directa Única Etapa GN  20 mbar Externa M26 x1.5m Interna 1/4" NPT h x 3/8” NPT h 3.2 m³/ h GNRegulator R4 Direct Acting Single Stage LPG 28 mbar M26 X 1.5 x 1/2" NPT h 360450 BTU/h LPGRegulator R10 Direct Acting Single Stage LPG 28 mbar 3/4" NPT h x 3/4" NPT h 863300 BTU/h LPGLow Pressure Cut-Off Regulator RCBP Self-Compensating Second Stage GN 35 mbar 1/2" NPT h x 1/2" NPT h 12 m³/ h GNRegulator R10 Direct Acting First Stage LPG 15 psi 1" NPT h x 1" NPT h 1691000 BTU/h LPGRegulator R10 Direct Acting First Stage LPG 140 mbar 1" NPT h x 1" NPT h 2207200 BTU/h LPG
Reference411341410818411267411504411262411260
Rating
Stock
Availability
Add to cart

Read more

Read more

Read more

Read more

Read more

Read more

DescriptionExternal use regulator for residential gas installations. Manufactured under NTC-3727 standard. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device.Regulator for internal use for residential gas installations. Reference Standard NTC-3293. With different flow rates according to the application and safety device Proportional Shut-Off and Low Pressure Cut-Off at the inlet.Regulator for external use for residential and commercial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
ContentInlet Pressure Min. 30 psi (2.07 bar). Max. Inlet Pressure 4.14 bar (60 psi). Outlet Pressure 20 mbar (8 "c.a.). Flow rate at inlet pressure Min. 3,2 m³/ h GN. With set pressure 4,5 m³/ h GN. External Inlet Connection M26 x1.5 Male Internal 1/4" NPT h Outlet Connection 3/8" NPT h.Inlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 5.5 bar (79.8 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate with inlet pressure MIN Flow rate 7.2Kg/h LPG, with set pressure Flow rate 10.3Kg/h LPG. Inlet connection M26 X 1,5 Outlet connection 1/2" NPT h.Inlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 6.9 bar (100 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate with inlet pressure MIN Flow rate 17.3Kg/h LPG. With set pressure Flow 30 Kg/h LPG. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT hInlet Pressure MIN. bar (1.5 psi). Inlet Pressure MAX. bar (9.9 psi). Outlet Pressure 35 mbar (14 "w.c.). Flow rate at inlet pressure inlet pressure MIN. m³/ h GN 12. with set pressure m³/ h GN 23. Inlet connection 1/2" NPT h Outlet connection 1/2" NPT hInlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 6.9 bar (100 psi). Outlet Pressure mbar 15 psi (1034 mbar). Flow rate at inlet pressure MIN Flow rate 33.9Kg/h LPG, at set pressure Flow rate 105.7Kg/h LPG . Inlet connection 1" NPT h Outlet connection 1" NPT h.Inlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 5.52 bar (80 psi). Outlet Pressure 140 mbar (56 "w.c.). Flow rate at inlet pressure MIN Flow rate 44.2Kg/h LPG, at set pressure Flow rate 54.4Kg/h LPG. Inlet connection 1" NPT h Outlet connection 1" NPT h.
Additional Information
Brand

Humcar

Connection Input

External M26 x1.5 Male Internal 1/4" NPT h

Connection Output

3/8" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

60 psi

Minimum inlet pressure

30 psi

Outlet pressure

20 mbar

Max. flow rate

3.2 m³/h GN

Nominal flow rate

4.5 m³/h GN

Brand

Humcar

Connection Input

5, M26 X 1

Connection Output

1/2" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

79.8

Minimum inlet pressure

20.3

Outlet pressure

28 mbar

Nominal flow rate

360450 BTU/h LPG

Brand

Humcar

Connection Input

3/4" NPT h

Connection Output

3/4" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

100

Minimum inlet pressure

20.3

Outlet pressure

28 mbar

Nominal flow rate

863300 BTU/h LPG

Brand

Humcar

Connection Input

1/2" NPT h

Connection Output

1/2" NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Proportional shut-off and low pressure cut-off at the inlet.

Maximum inlet pressure

9.9

Minimum inlet pressure

1.5

Outlet pressure

35 mbar

Nominal flow rate

12 m³/ h GN

Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

First Stage

Security System

Relief Valve.

Maximum inlet pressure

100

Minimum inlet pressure

20.3

Outlet pressure

15 psi

Nominal flow rate

1691000 BTU/h LPG

Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

First Stage

Security System

Relief Valve.

Maximum inlet pressure

80

Minimum inlet pressure

20.3

Outlet pressure

140 mbar

Nominal flow rate

2207200 BTU/h LPG

Cart
No products in the cart.
Notificaciones Judiciales
Email
WhatsApp
Phone
WhatsApp
Phone
Email
Notificaciones Judiciales
Select the fields to display
  • Image
  • Reference
  • Rating
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Additional Information
Click outside the comparison bar to close it.
Compare