• Home
  • Products
  • Regulador R204 Acción Directa Única Etapa GN 20 mbar Externa M26 x1.5m Interna 1/4″ NPT h x 3/8” NPT h 3.2 m³/ h GN

Regulador R204 Acción Directa Única Etapa GN 20 mbar Externa M26 x1.5m Interna 1/4″ NPT h x 3/8” NPT h 3.2 m³/ h GN

External use regulator for residential gas installations. Manufactured under NTC-3727 standard. With different flow rates according to the application and safety device relief valve.

Description

Inlet Pressure Min. 30 psi (2.07 bar). Max. Inlet Pressure 4.14 bar (60 psi). Outlet Pressure 20 mbar (8 "c.a.). Flow rate at inlet pressure Min. 3,2 m³/ h GN. With set pressure 4,5 m³/ h GN. External Inlet Connection M26 x1.5 Male Internal 1/4" NPT h Outlet Connection 3/8" NPT h.

Additional information

Brand

Humcar

Connection Input

External M26 x1.5 Male Internal 1/4" NPT h

Connection Output

3/8" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

60 psi

Minimum inlet pressure

30 psi

Outlet pressure

20 mbar

Max. flow rate

3.2 m³/h GN

Nominal flow rate

4.5 m³/h GN

Documents

Quick comparison

Regulador R204 Acción Directa Única Etapa GN 20 mbar Externa M26 x1.5m Interna 1/4" NPT h x 3/8” NPT h 3.2 m³/ h GN RemoverRegulator R10 Direct Acting First Stage LPG 15 psi 3/4" NPT h x 3/4" NPT h 1691000 BTU/h LPG RemoveRegulator R10 Direct Acting First Stage LPG 15 psi 1" NPT h x 1" NPT h 1691000 BTU/h LPG RemoveRegulator R10 RVI Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 768960 BTU/h LPG RemoveRegulator R50 Direct Acting Second Stage LPG 28 mbar 1" NPT h x 1" NPT h 1619800 BTU/h LPG RemoveRegulator R10 Direct Acting First Stage LPG 140 mbar 1" NPT h x 1" NPT h 2207200 BTU/h LPG Remove
NameRegulador R204 Acción Directa Única Etapa GN 20 mbar Externa M26 x1.5m Interna 1/4" NPT h x 3/8” NPT h 3.2 m³/ h GN RemoverRegulator R10 Direct Acting First Stage LPG 15 psi 3/4" NPT h x 3/4" NPT h 1691000 BTU/h LPG RemoveRegulator R10 Direct Acting First Stage LPG 15 psi 1" NPT h x 1" NPT h 1691000 BTU/h LPG RemoveRegulator R10 RVI Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 768960 BTU/h LPG RemoveRegulator R50 Direct Acting Second Stage LPG 28 mbar 1" NPT h x 1" NPT h 1619800 BTU/h LPG RemoveRegulator R10 Direct Acting First Stage LPG 140 mbar 1" NPT h x 1" NPT h 2207200 BTU/h LPG Remove
ImageRegulador R204  Acción Directa Única Etapa GN  20 mbar Externa M26 x1.5m Interna 1/4" NPT h x 3/8” NPT h 3.2 m³/ h GNRegulator R10 Direct Acting First Stage LPG 15 psi 3/4" NPT h x 3/4" NPT h 1691000 BTU/h LPGRegulator R10 Direct Acting First Stage LPG 15 psi 1" NPT h x 1" NPT h 1691000 BTU/h LPGRegulator R10 RVI Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 768960 BTU/h LPGRegulator R50 Direct Acting Second Stage LPG 28 mbar 1" NPT h x 1" NPT h 1619800 BTU/h LPGRegulator R10 Direct Acting First Stage LPG 140 mbar 1" NPT h x 1" NPT h 2207200 BTU/h LPG
Reference411341411261411262411245414003411260
Rating
Stock
Availability
Add to cart

Read more

Read more

Read more

Read more

Read more

Read more

DescriptionExternal use regulator for residential gas installations. Manufactured under NTC-3727 standard. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential and commercial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential and commercial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
ContentInlet Pressure Min. 30 psi (2.07 bar). Max. Inlet Pressure 4.14 bar (60 psi). Outlet Pressure 20 mbar (8 "c.a.). Flow rate at inlet pressure Min. 3,2 m³/ h GN. With set pressure 4,5 m³/ h GN. External Inlet Connection M26 x1.5 Male Internal 1/4" NPT h Outlet Connection 3/8" NPT h.Inlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 6.9 bar (100 psi). Outlet Pressure 15 psi (1034 mbar). Flow rate with inlet pressure MIN Flow rate 33.9 Kg/h LPG, with set pressure Flow rate 105.7 Kg/h LPG. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT h.Inlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 6.9 bar (100 psi). Outlet Pressure mbar 15 psi (1034 mbar). Flow rate at inlet pressure MIN Flow rate 33.9Kg/h LPG, at set pressure Flow rate 105.7Kg/h LPG . Inlet connection 1" NPT h Outlet connection 1" NPT h.Inlet Pressure MIN. 1.04 bar (15.1 psi). MAX Inlet Pressure. 6.9 bar (100 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate at inlet pressure MIN Flow rate 15.4Kg/h LPG, at set pressure Flow rate 22.1Kg/h LPG. Connection Inlet 1" NPT h Connection Outlet 1" NPT hInlet Pressure MIN. 0.21 bar (3 psi). MAX Inlet Pressure 2 bar (29 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate at inlet pressure inlet pressure MIN Flow rate Kg/h LPG: 32.5. with set pressure Flow rate Kg/h LPG: 46.4285714285714. Inlet connection 1" NPT h Outlet connection 1" NPT hInlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 5.52 bar (80 psi). Outlet Pressure 140 mbar (56 "w.c.). Flow rate at inlet pressure MIN Flow rate 44.2Kg/h LPG, at set pressure Flow rate 54.4Kg/h LPG. Inlet connection 1" NPT h Outlet connection 1" NPT h.
Additional Information
Brand

Humcar

Connection Input

External M26 x1.5 Male Internal 1/4" NPT h

Connection Output

3/8" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

60 psi

Minimum inlet pressure

30 psi

Outlet pressure

20 mbar

Max. flow rate

3.2 m³/h GN

Nominal flow rate

4.5 m³/h GN

Brand

Humcar

Connection Input

3/4" NPT h

Connection Output

3/4" NPT h

Type of Adjustment

Not Adjustable

Stage

First Stage

Security System

Relief Valve.

Maximum inlet pressure

100

Minimum inlet pressure

20.3

Outlet pressure

15 psi

Nominal flow rate

1691000 BTU/h LPG

Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

First Stage

Security System

Relief Valve.

Maximum inlet pressure

100

Minimum inlet pressure

20.3

Outlet pressure

15 psi

Nominal flow rate

1691000 BTU/h LPG

Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

100

Minimum inlet pressure

15.1

Outlet pressure

28 mbar

Nominal flow rate

768960 BTU/h LPG

Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Relief Valve.

Maximum inlet pressure

29

Minimum inlet pressure

3

Outlet pressure

28 mbar

Nominal flow rate

1619800 BTU/h LPG

Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

First Stage

Security System

Relief Valve.

Maximum inlet pressure

80

Minimum inlet pressure

20.3

Outlet pressure

140 mbar

Nominal flow rate

2207200 BTU/h LPG

Cart
No products in the cart.
Notificaciones Judiciales
Email
WhatsApp
Phone
WhatsApp
Phone
Email
Notificaciones Judiciales
Select the fields to display
  • Image
  • Reference
  • Rating
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Additional Information
Click outside the comparison bar to close it.
Compare