Regulator R50 Direct Acting Single Stage GN-GLP 22 mbar 1" NPT h x 1" NPTh
Regulator R50 Direct Acting Single Stage GN-GLP 22 mbar 1" NPT h x 1" NPTh
Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3727 and NTC-3873 . With different flow rates according to the application and safety device relief valve.
Inlet Pressure MIN. 1 bar (14.5 psi). Inlet Pressure MAX. 5.52 bar (80 psi). Outlet Pressure 22 mbar (8.8 "c.a.). Flow rate at inlet pressure MIN 40m³/ h GN - 46 kg/h LPG. Inlet connection 1" NPT h Outlet connection 1" NPT h.
Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3727 and NTC-3873 . With different flow rates according to the application and safety device relief valve.
Regulator for external use for residential gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device.
Regulator for internal use for residential gas installations. Reference Standard NTC-3293. With different flow rates according to the application and safety device Proportional Shut-Off and Low Pressure Cut-Off at the inlet.
Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
Regulator for internal use for residential gas installations. Reference Standard NTC-3293. With different flow rates according to the application and safety device Proportional Shut-Off and Low Pressure Cut-Off at the inlet.
External use regulator for commercial and industrial gas installations. Reference Standard NFPA-58 and NTC-3873. With different flow rates according to the application and safety device.
Content
Inlet Pressure MIN. 1 bar (14.5 psi). Inlet Pressure MAX. 5.52 bar (80 psi). Outlet Pressure 22 mbar (8.8 "c.a.). Flow rate at inlet pressure MIN 40m³/ h GN - 46 kg/h LPG. Inlet connection 1" NPT h Outlet connection 1" NPT h.
Inlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 6.9 bar (100 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate with inlet pressure MIN Flow rate 17.3Kg/h LPG, with set pressure Flow rate 30Kg/h LPG. Inlet connection 1" NPT h Outlet connection 1" NPT h
Inlet Pressure MIN. bar (1.5 psi). Inlet Pressure MAX. bar (9.9 psi). Outlet Pressure 35 mbar (14 "w.c.). Flow rate at inlet pressure
inlet pressure MIN. m³/ h GN 12. with set pressure m³/ h GN 23. Inlet connection 1/2" NPT h Outlet connection 1/2" NPT h
Inlet Pressure MIN. 0.7 bar (10.2 psi). MAX Inlet Pressure. 5.52 bar (80 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate with inlet pressure MIN 27.6Kg/h LPG, with set pressure Flow rate 84.8Kg/h LPG. Connection Inlet 1-1/4" NPT h Connection Outlet 1-1/4" NPT h.
Inlet Pressure MIN. bar (3 psi). Inlet Pressure MAX. bar (10 psi). Outlet Pressure 50 mbar (20 "c.a.). Flow rate at inlet pressure
inlet pressure MIN. m³/ h GN 20. with set pressure m³/ h GN 19. Inlet connection 1/2" NPT h Outlet connection 1/2" NPT h
Inlet Pressure Min. 2 bar (29 psi). Max. Inlet Pressure 100 psi (6.9 bar). Output Pressure 10 - 30 psi. Flow rate at inlet pressure Max. 3.365.482 BTU/h LPG. Inlet connection 1/2" NPT h Outlet connection 1/2" NPT h.
Additional Information
Brand
Humcar
Connection Input
1" NPT h
Connection Output
1" NPT h
Type of Adjustment
Not Adjustable
Stage
Single Stage
Security System
Relief Valve.
Maximum inlet pressure
80
Minimum inlet pressure
14.5
Outlet pressure
22 mbar
Nominal flow rate
40 m³/ h GN, 46 kg/h LPG
Brand
Humcar
Connection Input
1" NPT h
Connection Output
1" NPT h
Type of Adjustment
Not Adjustable
Stage
Single Stage
Security System
Relief Valve.
Maximum inlet pressure
100
Minimum inlet pressure
20.3
Outlet pressure
28 mbar
Nominal flow rate
863300 BTU/h LPG
Brand
Humcar
Connection Input
1/2" NPT h
Connection Output
1/2" NPT h
Type of Adjustment
Not Adjustable
Stage
Second Stage
Security System
Proportional shut-off and low pressure cut-off at the inlet.
Maximum inlet pressure
9.9
Minimum inlet pressure
1.5
Outlet pressure
35 mbar
Nominal flow rate
12 m³/ h GN
Brand
Humcar
Connection Input
1-1/4" NPT h
Connection Output
1-1/4" NPT h
Type of Adjustment
Not Adjustable
Stage
Single Stage
Security System
Relief Valve.
Maximum inlet pressure
80
Minimum inlet pressure
10.2
Outlet pressure
28 mbar
Nominal flow rate
1379500 BTU/h LPG
Brand
Humcar
Connection Input
1/2" NPT h
Connection Output
1/2" NPT h
Type of Adjustment
Not Adjustable
Stage
Second Stage
Security System
Proportional shut-off and low pressure cut-off at the inlet.
Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3727. With different flow rates according to the application and safety device relief valve.
Regulator for external use for residential installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
Regulator for external use for residential and commercial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.