• Home
  • Products
  • Regulator R50 Pilot Operated Indirect Acting First Stage NG - LPG 0 - 30 psi 1-1/4" NPT h x 1-1/4" NPT h 311 m³/ h NG - 201 m³/ h LPG

Regulator R50 Pilot Operated Indirect Acting First Stage NG - LPG 0 - 30 psi 1-1/4" NPT h x 1-1/4" NPT h 311 m³/ h NG - 201 m³/ h LPG

First stage regulator used in the handling of NG and LPG for commercial and industrial networks. Operating temperature: Minimum 3 °C Maximum 70 °C.

Description

Inlet Pressure MIN. 0.7 bar (10.2 psi). MAX Inlet Pressure 8.6 bar (124.7 psi). Outlet Pressure 0-30 psi. Inlet Connection 1-1/4" NPT h Outlet Connection 1-1/4" NPT h

Additional information

Brand

Humcar

Connection Input

1-1/4" NPT h

Connection Output

1-1/4" NPT h

Type of Adjustment

Adjustable

Stage

First Stage

Security System

Not applicable.

Maximum inlet pressure

124.7

Minimum inlet pressure

10.2

Outlet pressure

0 - 30 psi

Nominal flow rate

201 m³/ h LPG, 311 m³/ h GN

Documents

Quick comparison

Regulator R50 Pilot Operated Indirect Acting First Stage NG - LPG 0 - 30 psi 1-1/4" NPT h x 1-1/4" NPT h 311 m³/ h NG - 201 m³/ h LPG RemoveLow Pressure Cut-Off Regulator RCBP Self-Compensating Second Stage GN 50 mbar 1/2" NPT h x 1/2" NPT h 20 m³/ h GN RemoveRegulator R50 Direct Acting Second Stage GN 21 mbar 1 NPT h x 1 NPT h 43 m³/ h GN RemoveRegulator R10 Direct Acting Single Stage LPG 28 mbar 3/4" NPT h x 3/4" NPT h 863300 BTU/h LPG RemoveRegulator R50 Direct Acting Second Stage LPG 28 mbar 1" NPT h x 1" NPT h 1619800 BTU/h LPG RemoveRegulator R10 UPSO Direct Acting Single Stage GN 21 mbar 3/4" NPT h x 3/4" NPT h 10 m³/ h GN Remove
NameRegulator R50 Pilot Operated Indirect Acting First Stage NG - LPG 0 - 30 psi 1-1/4" NPT h x 1-1/4" NPT h 311 m³/ h NG - 201 m³/ h LPG RemoveLow Pressure Cut-Off Regulator RCBP Self-Compensating Second Stage GN 50 mbar 1/2" NPT h x 1/2" NPT h 20 m³/ h GN RemoveRegulator R50 Direct Acting Second Stage GN 21 mbar 1 NPT h x 1 NPT h 43 m³/ h GN RemoveRegulator R10 Direct Acting Single Stage LPG 28 mbar 3/4" NPT h x 3/4" NPT h 863300 BTU/h LPG RemoveRegulator R50 Direct Acting Second Stage LPG 28 mbar 1" NPT h x 1" NPT h 1619800 BTU/h LPG RemoveRegulator R10 UPSO Direct Acting Single Stage GN 21 mbar 3/4" NPT h x 3/4" NPT h 10 m³/ h GN Remove
ImageRegulator R50 Pilot Operated Indirect Acting First Stage NG - LPG 0 - 30 psi 1-1/4" NPT h x 1-1/4" NPT h 311 m³/ h NG - 201 m³/ h LPGLow Pressure Cut-Off Regulator RCBP Self-Compensating Second Stage GN 50 mbar 1/2" NPT h x 1/2" NPT h 20 m³/ h GNRegulator R50 Direct Acting Second Stage GN 21 mbar 1 NPT h x 1 NPT h 43 m³/ h GNRegulator R10 Direct Acting Single Stage LPG 28 mbar 3/4" NPT h x 3/4" NPT h 863300 BTU/h LPGRegulator R50 Direct Acting Second Stage LPG 28 mbar 1" NPT h x 1" NPT h 1619800 BTU/h LPGRegulator R10 UPSO Direct Acting Single Stage GN 21 mbar 3/4" NPT h x 3/4" NPT h 10 m³/ h GN
Reference414012411518414054411267414003411206
Rating
Stock
Availability
Add to cart

Read more

Read more

Read more

Read more

Read more

Read more

DescriptionFirst stage regulator used in the handling of NG and LPG for commercial and industrial networks. Operating temperature: Minimum 3 °C Maximum 70 °C.Regulator for internal use for residential gas installations. Reference Standard NTC-3293. With different flow rates according to the application and safety device Proportional Shut-Off and Low Pressure Cut-Off at the inlet.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3727. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.External use regulator for residential and commercial gas installations. Reference Standard MX-032-X-SCFI-2013 and specification ES.02260.MX-CN. With different flow rates according to the application and safety device relief valve and low pressure cut-off (UPSO).
ContentInlet Pressure MIN. 0.7 bar (10.2 psi). MAX Inlet Pressure 8.6 bar (124.7 psi). Outlet Pressure 0-30 psi. Inlet Connection 1-1/4" NPT h Outlet Connection 1-1/4" NPT hInlet Pressure MIN. bar (3 psi). Inlet Pressure MAX. bar (10 psi). Outlet Pressure 50 mbar (20 "c.a.). Flow rate at inlet pressure inlet pressure MIN. m³/ h GN 20. with set pressure m³/ h GN 19. Inlet connection 1/2" NPT h Outlet connection 1/2" NPT hInlet Pressure MIN. 0.14 bar (2 psi). MAX Inlet Pressure 0.35 bar (5 psi). Outlet Pressure 21 mbar (8.4 "w.c.). Flow rate at inlet pressure inlet pressure MIN Flow rate Kg/h LPG: 0. with set pressure m³/ h GN 43. Inlet connection 1 NPT h Outlet connection 1 NPT hInlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 6.9 bar (100 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate with inlet pressure MIN Flow rate 17.3Kg/h LPG. With set pressure Flow 30 Kg/h LPG. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT hPresión de Entrada MIN. 0.21 bar (3 psi). Presión de Entrada MÁX. 2 bar (29 psi). Presión de Salida 28 mbar (11.2 "c.a.). Caudal con presión de entrada MÍN Caudal Kg/h GLP: 32.5. con presión de ajuste Caudal Kg/h GLP: 46.4285714285714. Conexión Entrada 1” NPT h Conexión Salida 1” NPT hInlet Pressure MIN. 1 bar (14.5 psi). Inlet Pressure MAX. 4 bar (58 psi). Outlet Pressure 21 mbar (8.4 "w.c.). Flow rate at inlet pressure inlet pressure MIN Flow Kg/h LPG: 0. with set pressure m³/ h GN 10. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT h
Additional Information
Brand

Humcar

Connection Input

1-1/4" NPT h

Connection Output

1-1/4" NPT h

Type of Adjustment

Adjustable

Stage

First Stage

Security System

Not applicable.

Maximum inlet pressure

124.7

Minimum inlet pressure

10.2

Outlet pressure

0 - 30 psi

Nominal flow rate

201 m³/ h LPG, 311 m³/ h GN

Brand

Humcar

Connection Input

1/2" NPT h

Connection Output

1/2" NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Proportional shut-off and low pressure cut-off at the inlet.

Maximum inlet pressure

10

Minimum inlet pressure

3

Outlet pressure

50 mbar

Nominal flow rate

20 m³/ h GN

Brand

Humcar

Connection Input

1 NPT h

Connection Output

1 NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Relief Valve.

Maximum inlet pressure

5

Minimum inlet pressure

2

Outlet pressure

21 mbar

Nominal flow rate

43 m³/ h GN

Brand

Humcar

Connection Input

3/4" NPT h

Connection Output

3/4" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

100

Minimum inlet pressure

20.3

Outlet pressure

28 mbar

Nominal flow rate

863300 BTU/h LPG

Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Relief Valve.

Maximum inlet pressure

29

Minimum inlet pressure

3

Outlet pressure

28 mbar

Nominal flow rate

1619800 BTU/h LPG

Brand

Humcar

Connection Input

3/4" NPT h

Connection Output

3/4" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

58

Minimum inlet pressure

14.5

Outlet pressure

21 mbar

Nominal flow rate

10 m³/ h GN

Cart
No products in the cart.
Notificaciones Judiciales
Email
WhatsApp
Phone
WhatsApp
Phone
Email
Notificaciones Judiciales
Select the fields to display
  • Image
  • Reference
  • Rating
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Additional Information
Click outside the comparison bar to close it.
Compare