Inlet Pressure MIN. 0.7 bar (10.2 psi). Inlet Pressure MAX. 13.8 bar (200 psi). Outlet Pressure 350 mbar . Flow rate at inlet pressure setting 140 m³/ h GN - 90,5 m³/ h LPG. Inlet connection 1" NPT h Outlet connection 1" NPT h
Regulador de primera etapa utilizado en el manejo de GN y GLP para redes de tipo comercial e industrial.
Temperatura de operación: Minima -10 °C. Máxima 65 °C
Regulator for external use for installations with portable LPG cylinders. Reference Standard NTC-3873 With different flow rates according to the application and safety device.
Regulator for external use for residential installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
Regulator for internal use for residential gas installations. Reference Standard NTC-3293. With different flow rates according to the application and safety device Proportional Shut-Off and Low Pressure Cut-Off at the inlet.
Regulator for external use for residential gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
Content
Presión de Entrada MIN. 0.7 bar (10.2 psi). Presión de Entrada MÁX. 13.8 bar (200 psi). Presión de Salida 350 mbar . Caudal con presión de entrada de ajuste 140 m³/ h GN - 90,5 m³/ h GLP. Conexión Entrada 1” NPT h Conexión Salida 1” NPT h
Inlet Pressure MIN. 0.7 bar (10.2 psi). MAX Inlet Pressure. 7.5 bar (108.8 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate at inlet pressure
inlet pressure MIN Flow rate Kg/h LPG: 1.3. with set pressure Flow rate Kg/h LPG: . Inlet connection Quick coupling Ø35 mm Outlet connection Hose coupling 3/8".
Inlet Pressure MIN. 1.04 bar (15.1 psi). MAX Inlet Pressure. 6.9 bar (100 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate at inlet pressure MIN Flow rate 15.4Kg/h LPG, at set pressure Flow rate 22.1Kg/h LPG. Connection Inlet 1" NPT h Connection Outlet 1" NPT h
Inlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 5.52 bar (80 psi). Outlet Pressure 140 mbar (56 "w.c.). Flow rate with inlet pressure MIN Flow rate Kg/h 44.2GLP, with set pressure Flow rate 54.4Kg/h GLP. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT h
Inlet Pressure MIN. bar (3 psi). Inlet Pressure MAX. bar (10 psi). Outlet Pressure 50 mbar (20 "c.a.). Flow rate at inlet pressure
inlet pressure MIN. m³/ h GN 20. with set pressure m³/ h GN 19. Inlet connection 1/2" NPT h Outlet connection 1/2" NPT h
Inlet Pressure MIN. 0.7 bar (10.2 psi). MAX Inlet Pressure. 7 bar (100 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate with inlet pressure MIN Flow rate 1.4Kg/h LPG, with set pressure Flow rate 2.6Kg/h LPG. Connection Inlet M11 X 1 Connection Outlet 3/8" NPT h
Additional Information
Brand
Humcar
Connection Input
1" NPT h
Connection Output
1" NPT h
Type of Adjustment
Not Adjustable
Stage
First Stage
Security System
Not applicable.
Maximum inlet pressure
200
Minimum inlet pressure
10.2
Outlet pressure
350 mbar
Nominal flow rate
140 m³/ h GN, 90.5 m³/ h LPG
Brand
By Humcar
Connection Input
Quick Coupling Ø35 mm
Connection Output
3/8" Hose Coupling
Type of Adjustment
Not Adjustable
Stage
Single Stage
Security System
Not applicable.
Maximum inlet pressure
108.8
Minimum inlet pressure
10.2
Outlet pressure
28 mbar
Nominal flow rate
64792 BTU/h LPG
Brand
Humcar
Connection Input
1" NPT h
Connection Output
1" NPT h
Type of Adjustment
Not Adjustable
Stage
Single Stage
Security System
Relief Valve.
Maximum inlet pressure
100
Minimum inlet pressure
15.1
Outlet pressure
28 mbar
Nominal flow rate
768960 BTU/h LPG
Brand
Humcar
Connection Input
3/4" NPT h
Connection Output
3/4" NPT h
Type of Adjustment
Not Adjustable
Stage
First Stage
Security System
Relief Valve.
Maximum inlet pressure
80
Minimum inlet pressure
20.3
Outlet pressure
140 mbar
Nominal flow rate
2207200 BTU/h LPG
Brand
Humcar
Connection Input
1/2" NPT h
Connection Output
1/2" NPT h
Type of Adjustment
Not Adjustable
Stage
Second Stage
Security System
Proportional shut-off and low pressure cut-off at the inlet.
External use regulator for commercial and industrial gas installations. Reference Standard NFPA-58 and NTC-3873. With different flow rates according to the application and safety device.
Regulator for external use for residential gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3727. With different flow rates according to the application and safety device relief valve.
Regulator for external use for residential installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.