Regulator R50Plus 17.4mbar 3/4 "NPT h x 3/4 "NPT h 1/4″ Orif.1/4″ Orif.
Regulator R50Plus 17.4mbar 3/4 "NPT h x 3/4 "NPT h 1/4″ Orif.1/4″ Orif.
The R50 VA regulator is designed for the control and safety of NG and LPG gas networks in residential, medium commercial and small industrial applications. Available with output pressures for low and high pressure.
Presión de Entrada min. 0,3 bar (5 psi). Presión de Entrada Max. 5,5 bar (80 psi). Presión de Salida 17 mbar (7″c.a.). Conexión Entrada 3/4” NPT h Conexión Salida 3/4” NPT h
The R50 VA regulator is designed for the control and safety of NG and LPG gas networks in residential, medium commercial and small industrial applications. Available with output pressures for low and high pressure.
Regulator for internal use for residential gas installations. Reference Standard NTC-3293. With different flow rates according to the application and safety device Proportional Shut-Off and Low Pressure Cut-Off at the inlet.
Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3727. With different flow rates according to the application and safety device relief valve.
External use regulator for residential and commercial gas installations. Reference Standard MX-032-X-SCFI-2013 and specification ES.02260.MX-CN. With different flow rates according to the application and safety device relief valve and low pressure cut-off (UPSO).
Content
Presión de Entrada min. 0,3 bar (5 psi). Presión de Entrada Max. 5,5 bar (80 psi). Presión de Salida 17 mbar (7"c.a.). Conexión Entrada 3/4” NPT h Conexión Salida 3/4” NPT h
Inlet Pressure MIN. bar (1.5 psi). Inlet Pressure MAX. bar (9.9 psi). Outlet Pressure 35 mbar (14 "w.c.). Flow rate at inlet pressure
inlet pressure MIN. m³/ h GN 12. with set pressure m³/ h GN 23. Inlet connection 1/2" NPT h Outlet connection 1/2" NPT h
Presión de Entrada MIN. 0.21 bar (3 psi). Presión de Entrada MÁX. 2 bar (29 psi). Presión de Salida 28 mbar (11.2 "c.a.). Caudal con presión
de entrada MÍN Caudal Kg/h GLP: 32.5. con presión de ajuste Caudal Kg/h GLP: 46.4285714285714. Conexión Entrada 1” NPT h Conexión Salida 1” NPT h
Inlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 5.52 bar (80 psi). Outlet Pressure 140 mbar (56 "w.c.). Flow rate with inlet pressure MIN Flow rate Kg/h 44.2GLP, with set pressure Flow rate 54.4Kg/h GLP. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT h
Inlet Pressure MIN. 0.21 bar (3 psi). MAX Inlet Pressure 0.48 bar (7 psi). Outlet Pressure 100 mbar (40 "a.c.). Flow rate at inlet pressure
inlet pressure MIN. m³/ h GN 23. with set pressure m³/ h GN 35. Inlet connection 1 NPT h Outlet connection 1 NPT h
Inlet Pressure MIN. 1 bar (14.5 psi). Inlet Pressure MAX. 4 bar (58 psi). Outlet Pressure 21 mbar (8.4 "w.c.). Flow rate at inlet pressure
inlet pressure MIN Flow Kg/h LPG: 0. with set pressure m³/ h GN 10. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT h
Additional Information
Dimensions
28.6 × 20.5 × 16.3 cm (28.6 × 20.5 × 16.3 cm)
Brand
Humcar
Connection Input
3/4" NPTh
Connection Output
3/4" NPT h
Type of Adjustment
Not Adjustable
Security System
Relief Valve.
Brand
Humcar
Connection Input
1/2" NPT h
Connection Output
1/2" NPT h
Type of Adjustment
Not Adjustable
Stage
Second Stage
Security System
Proportional shut-off and low pressure cut-off at the inlet.
Regulator for external use for residential and commercial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3727. With different flow rates according to the application and safety device relief valve.
Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.