R50PLUS 50mbar 1-1/4 "NPTh x 1-1/4 NPTh Orif.1/2″ regulator
R50PLUS 50mbar 1-1/4 "NPTh x 1-1/4 NPTh Orif.1/2″ regulator
The R50 VA regulator is designed for the control and safety of NG and LPG gas networks in residential, medium commercial and small industrial applications. Available with output pressures for low and high pressure.
The R50 VA regulator is designed for the control and safety of NG and LPG gas networks in residential, medium commercial and small industrial applications. Available with output pressures for low and high pressure.
Regulator for internal use for residential gas installations. Reference Standard NTC-3293. With different flow rates according to the application and safety device Proportional Shut-Off and Low Pressure Cut-Off at the inlet.
Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
Regulator for internal use for residential gas installations. Reference Standard NTC-3293. With different flow rates according to the application and safety device Proportional Shut-Off and Low Pressure Cut-Off at the inlet.
Regulator for external use for residential gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
Content
Inlet Pressure min. 0.3 bar (5 psi). Max. inlet pressure 5,5 bar (80 psi). Outlet Pressure 50 mbar (20 "a.c.). Inlet connection 1-1/4" NPT h Outlet connection 1-1/4" NPT h
Inlet Pressure MIN. bar (3 psi). Inlet Pressure MAX. bar (10 psi). Outlet Pressure 50 mbar (20 "c.a.). Flow rate at inlet pressure
inlet pressure MIN. m³/ h GN 20. with set pressure m³/ h GN 19. Inlet connection 1/2" NPT h Outlet connection 1/2" NPT h
Inlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 5.52 bar (80 psi). Outlet Pressure 350 mbar (140 "w.c.). Flow rate at inlet pressure MIN Flow rate 44.2Kg/h LPG, at set pressure Flow rate 53.3Kg/h LPG. Inlet connection 1" NPT h Outlet connection 1" NPT h.
Inlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 5.52 bar (80 psi). Outlet Pressure 350 mbar (140 "w.c.). Flow rate with inlet pressure MIN Flow rate 44.2Kg/h LPG, with set pressure Flow rate 53.3Kg/h LPG. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT h.
Inlet Pressure MIN. bar (1.5 psi). Inlet Pressure MAX. bar (9.9 psi). Outlet Pressure 35 mbar (14 "w.c.). Flow rate at inlet pressure
inlet pressure MIN. m³/ h GN 12. with set pressure m³/ h GN 23. Inlet connection 1/2" NPT h Outlet connection 1/2" NPT h
Min. inlet pressure 0.2 bar (2.9 psi). Max. inlet pressure 1.4 bar (20.3 psi). Outlet pressure 28 mbar (11,2 "c.a.). Flow rate at min. inlet pressure 8.9 kg/h LPG (445,000 BTU/h LPG). Flow rate at set pressure 13.7Kg/h LPG (685,300 BTU/h LPG). Inlet connection 3/4" NPT h Outlet connection 3/4" NPT h
Additional Information
Dimensions
28.6 × 20.5 × 16.3 cm (28.6 × 20.5 × 16.3 cm)
Brand
Humcar
Connection Input
1 1/4" NPTh
Connection Output
1 1/4" NPTh
Security System
Relief Valve.
Brand
Humcar
Connection Input
1/2" NPT h
Connection Output
1/2" NPT h
Type of Adjustment
Not Adjustable
Stage
Second Stage
Security System
Proportional shut-off and low pressure cut-off at the inlet.
Maximum inlet pressure
10
Minimum inlet pressure
3
Outlet pressure
50 mbar
Nominal flow rate
20 m³/ h GN
Brand
Humcar
Connection Input
1" NPT h
Connection Output
1" NPT h
Type of Adjustment
Not Adjustable
Stage
First Stage
Security System
Relief Valve.
Maximum inlet pressure
80
Minimum inlet pressure
20.3
Outlet pressure
350 mbar
Nominal flow rate
2207200 BTU/h LPG
Brand
Humcar
Connection Input
3/4" NPT h
Connection Output
3/4" NPT h
Type of Adjustment
Not Adjustable
Stage
First Stage
Security System
Relief Valve.
Maximum inlet pressure
80
Minimum inlet pressure
20.3
Outlet pressure
350 mbar
Nominal flow rate
2207200 BTU/h LPG
Brand
Humcar
Connection Input
1/2" NPT h
Connection Output
1/2" NPT h
Type of Adjustment
Not Adjustable
Stage
Second Stage
Security System
Proportional shut-off and low pressure cut-off at the inlet.
External use regulator for commercial and industrial gas installations. Reference Standard NFPA-58 and NTC-3873. With different flow rates according to the application and safety device.
Regulator for external use for residential and commercial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
Regulator for external use for residential installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.