Regulator R6 Direct Acting Second Stage LPG 28 mbar M26 X 1.5 x 1/2" NPT h 267000 BTU/h LPG

Regulator for external use for residential gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.

SKU: 410920 Categories: , , , Tags: , , , , Regulator

Description

Presión de Entrada MIN. 0.21 bar (3 psi). Presión de Entrada MÁX. 0.35 bar (5 psi). Presión de Salida 28 mbar (11.2 “c.a.). Caudal con presión
de entrada MÍN Caudal Kg/h GLP: 5.36. con presión de ajuste Caudal Kg/h GLP: 5.35714285714286. Conexión Entrada M26 X 1,5 Conexión Salida 1/2” NPT h

Additional information

Brand

Humcar

Connection Input

5, M26 X 1

Connection Output

1/2" NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Relief Valve.

Maximum inlet pressure

5

Minimum inlet pressure

3

Outlet pressure

28 mbar

Nominal flow rate

267000 BTU/h LPG

Documents

Quick comparison

Regulator R6 Direct Acting Second Stage LPG 28 mbar M26 X 1.5 x 1/2" NPT h 267000 BTU/h LPG RemoveRegulator R4 Direct Acting Single Stage LPG 28 mbar M26 X 1.5 x 1/2" NPT h 360450 BTU/h LPG RemoveRegulator R10 Direct Acting First Stage LPG 140 mbar 3/4" NPT h x 3/4" NPT h 2207200 BTU/h LPG RemoveRegulator R10 Adjustable Direct Acting First Stage LPG 0.5 - 12.4 psi 3/4" NPT h x 3/4" NPT h 215736 BTU/h LPG RemoveLow Pressure Cut-Off Regulator RCBP Self-Compensating Second Stage GN 35 mbar 1/2" NPT h x 1/2" NPT h 12 m³/ h GN RemoveRegulator R50 Direct Acting Second Stage GN 21 mbar 1 NPT h x 1 NPT h 43 m³/ h GN Remove
NameRegulator R6 Direct Acting Second Stage LPG 28 mbar M26 X 1.5 x 1/2" NPT h 267000 BTU/h LPG RemoveRegulator R4 Direct Acting Single Stage LPG 28 mbar M26 X 1.5 x 1/2" NPT h 360450 BTU/h LPG RemoveRegulator R10 Direct Acting First Stage LPG 140 mbar 3/4" NPT h x 3/4" NPT h 2207200 BTU/h LPG RemoveRegulator R10 Adjustable Direct Acting First Stage LPG 0.5 - 12.4 psi 3/4" NPT h x 3/4" NPT h 215736 BTU/h LPG RemoveLow Pressure Cut-Off Regulator RCBP Self-Compensating Second Stage GN 35 mbar 1/2" NPT h x 1/2" NPT h 12 m³/ h GN RemoveRegulator R50 Direct Acting Second Stage GN 21 mbar 1 NPT h x 1 NPT h 43 m³/ h GN Remove
ImageRegulator R6 Direct Acting Second Stage LPG 28 mbar M26 X 1.5 x 1/2" NPT h 267000 BTU/h LPGRegulator R4 Direct Acting Single Stage LPG 28 mbar M26 X 1.5 x 1/2" NPT h 360450 BTU/h LPGRegulator R10 Direct Acting First Stage LPG 140 mbar 3/4" NPT h x 3/4" NPT h 2207200 BTU/h LPGRegulator R10 Adjustable Direct Acting First Stage LPG 0.5 - 12.4 psi 3/4" NPT h x 3/4" NPT h 215736 BTU/h LPGLow Pressure Cut-Off Regulator RCBP Self-Compensating Second Stage GN 35 mbar 1/2" NPT h x 1/2" NPT h 12 m³/ h GNRegulator R50 Direct Acting Second Stage GN 21 mbar 1 NPT h x 1 NPT h 43 m³/ h GN
Reference410920410818411259411255411504414054
Rating
Stock
Availability
Add to cart

Read more

Read more

Read more

Read more

Read more

Read more

DescriptionRegulator for external use for residential gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential and industrial gas installations. Reference Standard With different flow rates according to the application and safety device. Regulator for internal use for residential gas installations. Reference Standard NTC-3293. With different flow rates according to the application and safety device Proportional Shut-Off and Low Pressure Cut-Off at the inlet.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3727. With different flow rates according to the application and safety device relief valve.
ContentPresión de Entrada MIN. 0.21 bar (3 psi). Presión de Entrada MÁX. 0.35 bar (5 psi). Presión de Salida 28 mbar (11.2 "c.a.). Caudal con presión de entrada MÍN Caudal Kg/h GLP: 5.36. con presión de ajuste Caudal Kg/h GLP: 5.35714285714286. Conexión Entrada M26 X 1,5 Conexión Salida 1/2” NPT hInlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 5.5 bar (79.8 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate with inlet pressure MIN Flow rate 7.2Kg/h LPG, with set pressure Flow rate 10.3Kg/h LPG. Inlet connection M26 X 1,5 Outlet connection 1/2" NPT h.Inlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 5.52 bar (80 psi). Outlet Pressure 140 mbar (56 "w.c.). Flow rate with inlet pressure MIN Flow rate Kg/h 44.2GLP, with set pressure Flow rate 54.4Kg/h GLP. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT hInlet Pressure MIN. 1 bar (14.5 psi). Inlet Pressure MAX. 4.2 bar (60.9 psi). Outlet Pressure mbar ("c.a.). Flow rate at inlet pressure inlet pressure MIN Flow rate Kg/h LPG: 0. with set pressure Flow rate Kg/h LPG: . Inlet connection 3/4" NPT h Outlet connection 3/4" NPT hInlet Pressure MIN. bar (1.5 psi). Inlet Pressure MAX. bar (9.9 psi). Outlet Pressure 35 mbar (14 "w.c.). Flow rate at inlet pressure inlet pressure MIN. m³/ h GN 12. with set pressure m³/ h GN 23. Inlet connection 1/2" NPT h Outlet connection 1/2" NPT hInlet Pressure MIN. 0.14 bar (2 psi). MAX Inlet Pressure 0.35 bar (5 psi). Outlet Pressure 21 mbar (8.4 "w.c.). Flow rate at inlet pressure inlet pressure MIN Flow rate Kg/h LPG: 0. with set pressure m³/ h GN 43. Inlet connection 1 NPT h Outlet connection 1 NPT h
Additional Information
Brand

Humcar

Connection Input

5, M26 X 1

Connection Output

1/2" NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Relief Valve.

Maximum inlet pressure

5

Minimum inlet pressure

3

Outlet pressure

28 mbar

Nominal flow rate

267000 BTU/h LPG

Brand

Humcar

Connection Input

5, M26 X 1

Connection Output

1/2" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

79.8

Minimum inlet pressure

20.3

Outlet pressure

28 mbar

Nominal flow rate

360450 BTU/h LPG

Brand

Humcar

Connection Input

3/4" NPT h

Connection Output

3/4" NPT h

Type of Adjustment

Not Adjustable

Stage

First Stage

Security System

Relief Valve.

Maximum inlet pressure

80

Minimum inlet pressure

20.3

Outlet pressure

140 mbar

Nominal flow rate

2207200 BTU/h LPG

Brand

Humcar

Connection Input

3/4" NPT h

Connection Output

3/4" NPT h

Type of Adjustment

Adjustable

Stage

First Stage

Security System

Not applicable.

Maximum inlet pressure

60.9

Minimum inlet pressure

14.5

Outlet pressure

0.5 - 12.4 psi

Nominal flow rate

215736 BTU/h LPG

Brand

Humcar

Connection Input

1/2" NPT h

Connection Output

1/2" NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Proportional shut-off and low pressure cut-off at the inlet.

Maximum inlet pressure

9.9

Minimum inlet pressure

1.5

Outlet pressure

35 mbar

Nominal flow rate

12 m³/ h GN

Brand

Humcar

Connection Input

1 NPT h

Connection Output

1 NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Relief Valve.

Maximum inlet pressure

5

Minimum inlet pressure

2

Outlet pressure

21 mbar

Nominal flow rate

43 m³/ h GN

Cart
No products in the cart.
Notificaciones Judiciales
Email
WhatsApp
Phone
WhatsApp
Phone
Email
Notificaciones Judiciales
Select the fields to display
  • Image
  • Reference
  • Rating
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Additional Information
Click outside the comparison bar to close it.
Compare