• Home
  • Products
  • Regulator R6 Direct Acting Single Stage GN 23 mbar M26 X 1.5 x 1/2" NPT h 3.2 m³/ h GN

Regulator R6 Direct Acting Single Stage GN 23 mbar M26 X 1,5 x 1/2" NPT h 3.2 m³/ h GN

External use regulator for residential gas installations. Manufactured under NTC-3727 standard. With different flow rates according to the application and safety device relief valve.

Description

Inlet Pressure Min. 1.72 bar (24.9 psi). Max. Inlet Pressure 4 bar (58 psi). Outlet Pressure 23 mbar (9.2 "c.a.). Flow rate at inlet pressure Min. 3.2 m³/ h GN. With set pressure 8,72 m³/ h GN. Inlet connection M26 X 1,5 Outlet connection 1/2" NPT h.

Additional information

Brand

Humcar

Connection Input

M26 X 1

Connection Output

1/2" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

58 psi

Minimum inlet pressure

24.9 psi

Outlet pressure

23 mbar

Max. flow rate

3.2 m³/h GN

Nominal flow rate

8.72 m³/h GN

Documents

Quick comparison

Regulator R6 Direct Action Single Stage GN 23 mbar M26 X 1,5 x 1/2" NPT h 3.2 m³/ h GN RemoveRegulator R50 Direct Acting Single Stage LPG 28 mbar 1-1/4" NPT h x 1-1/4" NPT h 1379500 BTU/h LPG RemoveRegulator R10 Direct Acting Second Stage LPG 28mbar 3/4 "NPTh x 3/4 "NPTh 445000 BTU/h LPG RemoveRegulator R4 Direct Acting Single Stage LPG 28 mbar M26 X 1.5 x 1/2" NPT h 360450 BTU/h LPG RemoveRegulator R10 Direct Acting First Stage LPG 15 psi 1" NPT h x 1" NPT h 1691000 BTU/h LPG RemoveRegulator R50 Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 1379500 BTU/h LPG Remove
NameRegulator R6 Direct Action Single Stage GN 23 mbar M26 X 1,5 x 1/2" NPT h 3.2 m³/ h GN RemoveRegulator R50 Direct Acting Single Stage LPG 28 mbar 1-1/4" NPT h x 1-1/4" NPT h 1379500 BTU/h LPG RemoveRegulator R10 Direct Acting Second Stage LPG 28mbar 3/4 "NPTh x 3/4 "NPTh 445000 BTU/h LPG RemoveRegulator R4 Direct Acting Single Stage LPG 28 mbar M26 X 1.5 x 1/2" NPT h 360450 BTU/h LPG RemoveRegulator R10 Direct Acting First Stage LPG 15 psi 1" NPT h x 1" NPT h 1691000 BTU/h LPG RemoveRegulator R50 Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 1379500 BTU/h LPG Remove
ImageRegulator R6 Direct Acting Single Stage GN 23 mbar M26 X 1,5 x 1/2" NPT h 3.2 m³/ h GNRegulator R50 Direct Acting Single Stage LPG 28 mbar 1-1/4" NPT h x 1-1/4" NPT h 1379500 BTU/h LPGRegulator R10 Direct Action Second Stage LPG 28mbar 3/4 "NPTh x 3/4 "NPTh 445000 BTU/h LPGRegulator R4 Direct Acting Single Stage LPG 28 mbar M26 X 1.5 x 1/2" NPT h 360450 BTU/h LPGRegulator R10 Direct Acting First Stage LPG 15 psi 1" NPT h x 1" NPT h 1691000 BTU/h LPGRegulator R50 Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 1379500 BTU/h LPG
Reference410912414002411265410818411262414001
Rating
Stock
Availability
Add to cart

Read more

Read more

Read more

Read more

Read more

Read more

DescriptionExternal use regulator for residential gas installations. Manufactured under NTC-3727 standard. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential and commercial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
ContentInlet Pressure Min. 1.72 bar (24.9 psi). Max. Inlet Pressure 4 bar (58 psi). Outlet Pressure 23 mbar (9.2 "c.a.). Flow rate at inlet pressure Min. 3.2 m³/ h GN. With set pressure 8,72 m³/ h GN. Inlet connection M26 X 1,5 Outlet connection 1/2" NPT h.Inlet Pressure MIN. 0.7 bar (10.2 psi). MAX Inlet Pressure. 5.52 bar (80 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate with inlet pressure MIN 27.6Kg/h LPG, with set pressure Flow rate 84.8Kg/h LPG. Connection Inlet 1-1/4" NPT h Connection Outlet 1-1/4" NPT h.Min. inlet pressure 0.2 bar (2.9 psi). Max. inlet pressure 1.4 bar (20.3 psi). Outlet pressure 28 mbar (11,2 "c.a.). Flow rate at min. inlet pressure 8.9 kg/h LPG (445,000 BTU/h LPG). Flow rate at set pressure 13.7Kg/h LPG (685,300 BTU/h LPG). Inlet connection 3/4" NPT h Outlet connection 3/4" NPT hInlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 5.5 bar (79.8 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate with inlet pressure MIN Flow rate 7.2Kg/h LPG, with set pressure Flow rate 10.3Kg/h LPG. Inlet connection M26 X 1,5 Outlet connection 1/2" NPT h.Inlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 6.9 bar (100 psi). Outlet Pressure mbar 15 psi (1034 mbar). Flow rate at inlet pressure MIN Flow rate 33.9Kg/h LPG, at set pressure Flow rate 105.7Kg/h LPG . Inlet connection 1" NPT h Outlet connection 1" NPT h.Inlet Pressure MIN. 0.7 bar (10.2 psi). MAX Inlet Pressure. 5.52 bar (80 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate at inlet pressure MIN Flow rate 27.6Kg/h LPG, at set pressure Flow rate 84.8Kg/h LPG. Inlet connection 1" NPT h Outlet connection 1" NPT h.
Additional Information
Brand

Humcar

Connection Input

M26 X 1

Connection Output

1/2" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

58 psi

Minimum inlet pressure

24.9 psi

Outlet pressure

23 mbar

Max. flow rate

3.2 m³/h GN

Nominal flow rate

8.72 m³/h GN

Brand

Humcar

Connection Input

1-1/4" NPT h

Connection Output

1-1/4" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

80

Minimum inlet pressure

10.2

Outlet pressure

28 mbar

Nominal flow rate

1379500 BTU/h LPG

Brand

Humcar

Connection Input

3/4" NPT h

Connection Output

3/4" NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Relief Valve.

Maximum inlet pressure

20.3 psi

Minimum inlet pressure

2.9 psi

Outlet pressure

28 mbar

Nominal flow rate

445000 BTU/h LPG

Brand

Humcar

Connection Input

5, M26 X 1

Connection Output

1/2" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

79.8

Minimum inlet pressure

20.3

Outlet pressure

28 mbar

Nominal flow rate

360450 BTU/h LPG

Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

First Stage

Security System

Relief Valve.

Maximum inlet pressure

100

Minimum inlet pressure

20.3

Outlet pressure

15 psi

Nominal flow rate

1691000 BTU/h LPG

Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

80

Minimum inlet pressure

10.2

Outlet pressure

28 mbar

Nominal flow rate

1379500 BTU/h LPG

Cart
No products in the cart.
Notificaciones Judiciales
Email
WhatsApp
Phone
WhatsApp
Phone
Email
Notificaciones Judiciales
Select the fields to display
  • Image
  • Reference
  • Rating
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Additional Information
Click outside the comparison bar to close it.
Compare