• Home
  • Products
  • Regulator R7 UPSO 180° Direct Acting Single Stage GN 23 - 25 mbar G 3/4 h SC x G 3/4 h JP 6 m³/ h GN

Regulator R7 UPSO 180° Direct Acting Single Stage GN 23 - 25 mbar G 3/4 h SC x G 3/4 h JP 6 m³/ h GN

Regulator for external use for residential gas installations. Reference Standard NTC-3727. With different flow rates according to the application and safety device, relief valve, low pressure cut-off at the inlet and diaphragm rupture.

Description

Inlet Pressure MIN. 1 bar (14.5 psi). Inlet Pressure MAX. 6 bar (87 psi). Outlet Pressure 23 - 25 mbar ("c.a.). Flow rate at inlet pressure
inlet pressure MIN m³/ h GN 6. with set pressure m³/ h GN 9.6. Inlet connection G 3/4 h SC Outlet connection G 3/4 h JP

Additional information

Brand

Humcar

Connection Input

G 3/4 h SC

Connection Output

G 3/4 h JP

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

low inlet pressure shutoff and diaphragm rupture, Relief Valve

Maximum inlet pressure

87

Minimum inlet pressure

14.5

Outlet pressure

23 - 25 mbar

Nominal flow rate

6 m³/ h GN

Documents

Quick comparison

Regulator R7 UPSO 180° Direct Acting Single Stage GN 23 - 25 mbar G 3/4 h SC x G 3/4 h JP 6 m³/ h GN RemoveRegulator R10 Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 863300 BTU/h LPG RemoveRegulator R10 Direct Acting First Stage LPG 15 psi 1" NPT h x 1" NPT h 1691000 BTU/h LPG RemoveLow Pressure Cut-Off Regulator RCBP Self-Compensating Second Stage GN 50 mbar 1/2" NPT h x 1/2" NPT h 20 m³/ h GN RemoveRegulator R101 Direct Acting Single Stage LPG 28 mbar M11 X 1 x 3/8" NPT h 72090 BTU/h LPG RemoveRegulator R10 Direct Acting Second Stage LPG 28mbar 3/4 "NPTh x 3/4 "NPTh 445000 BTU/h LPG Remove
NameRegulator R7 UPSO 180° Direct Acting Single Stage GN 23 - 25 mbar G 3/4 h SC x G 3/4 h JP 6 m³/ h GN RemoveRegulator R10 Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 863300 BTU/h LPG RemoveRegulator R10 Direct Acting First Stage LPG 15 psi 1" NPT h x 1" NPT h 1691000 BTU/h LPG RemoveLow Pressure Cut-Off Regulator RCBP Self-Compensating Second Stage GN 50 mbar 1/2" NPT h x 1/2" NPT h 20 m³/ h GN RemoveRegulator R101 Direct Acting Single Stage LPG 28 mbar M11 X 1 x 3/8" NPT h 72090 BTU/h LPG RemoveRegulator R10 Direct Acting Second Stage LPG 28mbar 3/4 "NPTh x 3/4 "NPTh 445000 BTU/h LPG Remove
ImageRegulator R7 UPSO 180° Direct Acting Single Stage GN 23 - 25 mbar G 3/4 h SC x G 3/4 h JP 6 m³/ h GNRegulator R10 Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 863300 BTU/h LPGRegulator R10 Direct Acting First Stage LPG 15 psi 1" NPT h x 1" NPT h 1691000 BTU/h LPGLow Pressure Cut-Off Regulator RCBP Self-Compensating Second Stage GN 50 mbar 1/2" NPT h x 1/2" NPT h 20 m³/ h GNRegulator R101 Direct Acting Single Stage LPG 28 mbar M11 X 1 x 3/8" NPT h 72090 BTU/h LPGRegulator R10 Direct Action Second Stage LPG 28mbar 3/4 "NPTh x 3/4 "NPTh 445000 BTU/h LPG
Reference411071411268411262411518410880411265
Rating
Stock
Availability
Add to cart

Read more

Read more

Read more

Read more

Read more

Read more

DescriptionRegulator for external use for residential gas installations. Reference Standard NTC-3727. With different flow rates according to the application and safety device, relief valve, low pressure cut-off at the inlet and diaphragm rupture.Regulator for external use for residential gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device.Regulator for external use for residential and commercial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for internal use for residential gas installations. Reference Standard NTC-3293. With different flow rates according to the application and safety device Proportional Shut-Off and Low Pressure Cut-Off at the inlet.Regulator for external use for residential gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
ContentInlet Pressure MIN. 1 bar (14.5 psi). Inlet Pressure MAX. 6 bar (87 psi). Outlet Pressure 23 - 25 mbar ("c.a.). Flow rate at inlet pressure inlet pressure MIN m³/ h GN 6. with set pressure m³/ h GN 9.6. Inlet connection G 3/4 h SC Outlet connection G 3/4 h JP Inlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 6.9 bar (100 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate with inlet pressure MIN Flow rate 17.3Kg/h LPG, with set pressure Flow rate 30Kg/h LPG. Inlet connection 1" NPT h Outlet connection 1" NPT hInlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 6.9 bar (100 psi). Outlet Pressure mbar 15 psi (1034 mbar). Flow rate at inlet pressure MIN Flow rate 33.9Kg/h LPG, at set pressure Flow rate 105.7Kg/h LPG . Inlet connection 1" NPT h Outlet connection 1" NPT h.Inlet Pressure MIN. bar (3 psi). Inlet Pressure MAX. bar (10 psi). Outlet Pressure 50 mbar (20 "c.a.). Flow rate at inlet pressure inlet pressure MIN. m³/ h GN 20. with set pressure m³/ h GN 19. Inlet connection 1/2" NPT h Outlet connection 1/2" NPT hInlet Pressure MIN. 0.7 bar (10.2 psi). MAX Inlet Pressure. 7 bar (100 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate with inlet pressure MIN Flow rate 1.4Kg/h LPG, with set pressure Flow rate 2.6Kg/h LPG. Connection Inlet M11 X 1 Connection Outlet 3/8" NPT hMin. inlet pressure 0.2 bar (2.9 psi). Max. inlet pressure 1.4 bar (20.3 psi). Outlet pressure 28 mbar (11,2 "c.a.). Flow rate at min. inlet pressure 8.9 kg/h LPG (445,000 BTU/h LPG). Flow rate at set pressure 13.7Kg/h LPG (685,300 BTU/h LPG). Inlet connection 3/4" NPT h Outlet connection 3/4" NPT h
Additional Information
Brand

Humcar

Connection Input

G 3/4 h SC

Connection Output

G 3/4 h JP

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

low inlet pressure shutoff and diaphragm rupture, Relief Valve

Maximum inlet pressure

87

Minimum inlet pressure

14.5

Outlet pressure

23 - 25 mbar

Nominal flow rate

6 m³/ h GN

Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

100

Minimum inlet pressure

20.3

Outlet pressure

28 mbar

Nominal flow rate

863300 BTU/h LPG

Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

First Stage

Security System

Relief Valve.

Maximum inlet pressure

100

Minimum inlet pressure

20.3

Outlet pressure

15 psi

Nominal flow rate

1691000 BTU/h LPG

Brand

Humcar

Connection Input

1/2" NPT h

Connection Output

1/2" NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Proportional shut-off and low pressure cut-off at the inlet.

Maximum inlet pressure

10

Minimum inlet pressure

3

Outlet pressure

50 mbar

Nominal flow rate

20 m³/ h GN

Brand

Humcar

Connection Input

M11 X 1

Connection Output

3/8" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

100

Minimum inlet pressure

10.2

Outlet pressure

28 mbar

Nominal flow rate

72090 BTU/h LPG

Brand

Humcar

Connection Input

3/4" NPT h

Connection Output

3/4" NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Relief Valve.

Maximum inlet pressure

20.3 psi

Minimum inlet pressure

2.9 psi

Outlet pressure

28 mbar

Nominal flow rate

445000 BTU/h LPG

Cart
No products in the cart.
Notificaciones Judiciales
Email
WhatsApp
Phone
WhatsApp
Phone
Email
Notificaciones Judiciales
Select the fields to display
  • Image
  • Reference
  • Rating
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Additional Information
Click outside the comparison bar to close it.
Compare