• Home
  • Products
  • Regulator R7 UPSO 180° Direct Acting Single Stage GN 23 mbar G 3/4 h SC x G 3/4 h JP 6 m³/ h GN

Regulator R7 UPSO 180° Direct Acting Single Stage GN 23 mbar G 3/4 h SC x G 3/4 h JP 6 m³/ h GN

External use regulator for residential gas installations. Manufactured under NTC-3727 standard. With different flow rates according to the application and safety device, relief valve, low pressure cut-off at the inlet, excess flow at the outlet and diaphragm rupture.

Description

Inlet Pressure MIN. 0.7 bar (10.2 psi). Inlet Pressure MAX. 5 bar (72.5 psi). Outlet Pressure 23 mbar (9.2 "w.c.). Flow rate at inlet pressure
inlet pressure MIN m³/ h GN 6. with set pressure m³/ h GN 8. Inlet connection G 3/4 h SC Outlet connection G 3/4 h JP

Additional information

Brand

Humcar

Connection Input

G 3/4 h SC

Connection Output

G 3/4 h JP

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

low inlet pressure shut-off, excess flow at the outlet and diaphragm rupture, Relief Valve

Maximum inlet pressure

72.5

Minimum inlet pressure

10.2

Outlet pressure

23 mbar

Nominal flow rate

6 m³/ h GN

Documents

Quick comparison

Regulator R7 UPSO 180° Direct Acting Single Stage GN 23 mbar G 3/4 h SC x G 3/4 h JP 6 m³/ h GN RemoveRegulator R10 Direct Acting First Stage LPG 140 mbar 3/4" NPT h x 3/4" NPT h 2207200 BTU/h LPG RemoveRegulator R10 Direct Acting First Stage LPG 350 mbar 3/4" NPT h x 3/4" NPT h 2207200 BTU/h LPG RemoveRegulator R10 Direct Acting Single Stage LPG 28 mbar 3/4" NPT h x 3/4" NPT h 863300 BTU/h LPG RemoveLow Pressure Cut-Off Regulator RCBP Self-Compensating Second Stage GN 50 mbar 1/2" NPT h x 1/2" NPT h 20 m³/ h GN RemoveRegulator R10 Direct Acting First Stage LPG 140 mbar 1" NPT h x 1" NPT h 2207200 BTU/h LPG Remove
NameRegulator R7 UPSO 180° Direct Acting Single Stage GN 23 mbar G 3/4 h SC x G 3/4 h JP 6 m³/ h GN RemoveRegulator R10 Direct Acting First Stage LPG 140 mbar 3/4" NPT h x 3/4" NPT h 2207200 BTU/h LPG RemoveRegulator R10 Direct Acting First Stage LPG 350 mbar 3/4" NPT h x 3/4" NPT h 2207200 BTU/h LPG RemoveRegulator R10 Direct Acting Single Stage LPG 28 mbar 3/4" NPT h x 3/4" NPT h 863300 BTU/h LPG RemoveLow Pressure Cut-Off Regulator RCBP Self-Compensating Second Stage GN 50 mbar 1/2" NPT h x 1/2" NPT h 20 m³/ h GN RemoveRegulator R10 Direct Acting First Stage LPG 140 mbar 1" NPT h x 1" NPT h 2207200 BTU/h LPG Remove
ImageRegulator R7 UPSO 180° Direct Acting Single Stage GN 23 mbar G 3/4 h SC x G 3/4 h JP 6 m³/ h GNRegulator R10 Direct Acting First Stage LPG 140 mbar 3/4" NPT h x 3/4" NPT h 2207200 BTU/h LPGRegulator R10 Direct Acting LPG First Stage 350 mbar 3/4" NPT h x 3/4" NPT h 2207200 BTU/h LPGRegulator R10 Direct Acting Single Stage LPG 28 mbar 3/4" NPT h x 3/4" NPT h 863300 BTU/h LPGLow Pressure Cut-Off Regulator RCBP Self-Compensating Second Stage GN 50 mbar 1/2" NPT h x 1/2" NPT h 20 m³/ h GNRegulator R10 Direct Acting First Stage LPG 140 mbar 1" NPT h x 1" NPT h 2207200 BTU/h LPG
Reference411052411259411257411267411518411260
Rating
Stock
Availability
Add to cart

Read more

Read more

Read more

Read more

Read more

Read more

DescriptionExternal use regulator for residential gas installations. Manufactured under NTC-3727 standard. With different flow rates according to the application and safety device, relief valve, low pressure cut-off at the inlet, excess flow at the outlet and diaphragm rupture.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device.Regulator for internal use for residential gas installations. Reference Standard NTC-3293. With different flow rates according to the application and safety device Proportional Shut-Off and Low Pressure Cut-Off at the inlet.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
ContentInlet Pressure MIN. 0.7 bar (10.2 psi). Inlet Pressure MAX. 5 bar (72.5 psi). Outlet Pressure 23 mbar (9.2 "w.c.). Flow rate at inlet pressure inlet pressure MIN m³/ h GN 6. with set pressure m³/ h GN 8. Inlet connection G 3/4 h SC Outlet connection G 3/4 h JP Inlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 5.52 bar (80 psi). Outlet Pressure 140 mbar (56 "w.c.). Flow rate with inlet pressure MIN Flow rate Kg/h 44.2GLP, with set pressure Flow rate 54.4Kg/h GLP. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT hInlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 5.52 bar (80 psi). Outlet Pressure 350 mbar (140 "w.c.). Flow rate with inlet pressure MIN Flow rate 44.2Kg/h LPG, with set pressure Flow rate 53.3Kg/h LPG. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT h.Inlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 6.9 bar (100 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate with inlet pressure MIN Flow rate 17.3Kg/h LPG. With set pressure Flow 30 Kg/h LPG. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT hInlet Pressure MIN. bar (3 psi). Inlet Pressure MAX. bar (10 psi). Outlet Pressure 50 mbar (20 "c.a.). Flow rate at inlet pressure inlet pressure MIN. m³/ h GN 20. with set pressure m³/ h GN 19. Inlet connection 1/2" NPT h Outlet connection 1/2" NPT hInlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 5.52 bar (80 psi). Outlet Pressure 140 mbar (56 "w.c.). Flow rate at inlet pressure MIN Flow rate 44.2Kg/h LPG, at set pressure Flow rate 54.4Kg/h LPG. Inlet connection 1" NPT h Outlet connection 1" NPT h.
Additional Information
Brand

Humcar

Connection Input

G 3/4 h SC

Connection Output

G 3/4 h JP

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

low inlet pressure shut-off, excess flow at the outlet and diaphragm rupture, Relief Valve

Maximum inlet pressure

72.5

Minimum inlet pressure

10.2

Outlet pressure

23 mbar

Nominal flow rate

6 m³/ h GN

Brand

Humcar

Connection Input

3/4" NPT h

Connection Output

3/4" NPT h

Type of Adjustment

Not Adjustable

Stage

First Stage

Security System

Relief Valve.

Maximum inlet pressure

80

Minimum inlet pressure

20.3

Outlet pressure

140 mbar

Nominal flow rate

2207200 BTU/h LPG

Brand

Humcar

Connection Input

3/4" NPT h

Connection Output

3/4" NPT h

Type of Adjustment

Not Adjustable

Stage

First Stage

Security System

Relief Valve.

Maximum inlet pressure

80

Minimum inlet pressure

20.3

Outlet pressure

350 mbar

Nominal flow rate

2207200 BTU/h LPG

Brand

Humcar

Connection Input

3/4" NPT h

Connection Output

3/4" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

100

Minimum inlet pressure

20.3

Outlet pressure

28 mbar

Nominal flow rate

863300 BTU/h LPG

Brand

Humcar

Connection Input

1/2" NPT h

Connection Output

1/2" NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Proportional shut-off and low pressure cut-off at the inlet.

Maximum inlet pressure

10

Minimum inlet pressure

3

Outlet pressure

50 mbar

Nominal flow rate

20 m³/ h GN

Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

First Stage

Security System

Relief Valve.

Maximum inlet pressure

80

Minimum inlet pressure

20.3

Outlet pressure

140 mbar

Nominal flow rate

2207200 BTU/h LPG

Cart
No products in the cart.
Notificaciones Judiciales
Email
WhatsApp
Phone
WhatsApp
Phone
Email
Notificaciones Judiciales
Select the fields to display
  • Image
  • Reference
  • Rating
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Additional Information
Click outside the comparison bar to close it.
Compare