• Home
  • Products
  • Regulator R7 UPSO 90° Direct Acting Single Stage GN 23 - 25 mbar G 3/4 h SC x G 3/4 h JP 6 m³/ h GN

Regulator R7 UPSO 90° Direct Acting Single Stage GN 23 - 25 mbar G 3/4 h SC x G 3/4 h JP 6 m³/ h GN

Regulator for external use for residential gas installations. Reference Standard NTC-3727. With different flow rates according to the application and safety device, relief valve, low pressure cut-off at the inlet and diaphragm rupture.

Description

Inlet Pressure MIN. 1 bar (14.5 psi). Inlet Pressure MAX. 6 bar (87 psi). Outlet Pressure 23 - 25 mbar ("c.a.). Flow rate at inlet pressure
inlet pressure MIN m³/ h GN 6. with set pressure m³/ h GN 7.8. Inlet connection G 3/4 h SC Outlet connection G 3/4 h JP

Additional information

Brand

Humcar

Connection Input

G 3/4 h SC

Connection Output

G 3/4 h JP

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

low inlet pressure shutoff and diaphragm rupture, Relief Valve

Maximum inlet pressure

87

Minimum inlet pressure

14.5

Outlet pressure

23 - 25 mbar

Nominal flow rate

6 m³/ h GN

Documents

Quick comparison

Regulator R7 UPSO 90° Direct Acting Single Stage GN 23 - 25 mbar G 3/4 h SC x G 3/4 h JP 6 m³/ h GN RemoveRegulator R50 Direct Acting Second Stage LPG 28 mbar 1" NPT h x 1" NPT h 1619800 BTU/h LPG RemoveHigh Pressure Regulator Direct Acting First Stage LPG 10 - 30 psi 1/2" NPT h x 1/2" NPT h 3365482 BTU/h LPG RemoveRegulator R50 Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 1379500 BTU/h LPG RemoveRegulator R10 Adjustable Direct Acting First Stage LPG 0.5 - 12.4 psi 3/4" NPT h x 3/4" NPT h 215736 BTU/h LPG RemoveRegulator R4 Direct Acting Single Stage LPG 28 mbar M26 X 1.5 x 1/2" NPT h 360450 BTU/h LPG Remove
NameRegulator R7 UPSO 90° Direct Acting Single Stage GN 23 - 25 mbar G 3/4 h SC x G 3/4 h JP 6 m³/ h GN RemoveRegulator R50 Direct Acting Second Stage LPG 28 mbar 1" NPT h x 1" NPT h 1619800 BTU/h LPG RemoveHigh Pressure Regulator Direct Acting First Stage LPG 10 - 30 psi 1/2" NPT h x 1/2" NPT h 3365482 BTU/h LPG RemoveRegulator R50 Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 1379500 BTU/h LPG RemoveRegulator R10 Adjustable Direct Acting First Stage LPG 0.5 - 12.4 psi 3/4" NPT h x 3/4" NPT h 215736 BTU/h LPG RemoveRegulator R4 Direct Acting Single Stage LPG 28 mbar M26 X 1.5 x 1/2" NPT h 360450 BTU/h LPG Remove
ImageRegulator R7 UPSO 90° Direct Acting Single Stage GN 23 - 25 mbar G 3/4 h SC x G 3/4 h JP 6 m³/ h GNRegulator R50 Direct Acting Second Stage LPG 28 mbar 1" NPT h x 1" NPT h 1619800 BTU/h LPGHigh Pressure Regulator Direct Acting First Stage LPG 10 - 30 psi 1/2" NPT h x 1/2" NPT h 3365482 BTU/h LPGRegulator R50 Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 1379500 BTU/h LPGRegulator R10 Adjustable Direct Acting First Stage LPG 0.5 - 12.4 psi 3/4" NPT h x 3/4" NPT h 215736 BTU/h LPGRegulator R4 Direct Acting Single Stage LPG 28 mbar M26 X 1.5 x 1/2" NPT h 360450 BTU/h LPG
Reference411076414003410200414001411255410818
Rating
Stock
Availability
Add to cart

Read more

Read more

Read more

Read more

Read more

Read more

DescriptionRegulator for external use for residential gas installations. Reference Standard NTC-3727. With different flow rates according to the application and safety device, relief valve, low pressure cut-off at the inlet and diaphragm rupture.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.External use regulator for commercial and industrial gas installations. Reference Standard NFPA-58 and NTC-3873. With different flow rates according to the application and safety device.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential and industrial gas installations. Reference Standard With different flow rates according to the application and safety device. Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
ContentInlet Pressure MIN. 1 bar (14.5 psi). Inlet Pressure MAX. 6 bar (87 psi). Outlet Pressure 23 - 25 mbar ("c.a.). Flow rate at inlet pressure inlet pressure MIN m³/ h GN 6. with set pressure m³/ h GN 7.8. Inlet connection G 3/4 h SC Outlet connection G 3/4 h JP Inlet Pressure MIN. 0.21 bar (3 psi). MAX Inlet Pressure 2 bar (29 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate at inlet pressure inlet pressure MIN Flow rate Kg/h LPG: 32.5. with set pressure Flow rate Kg/h LPG: 46.4285714285714. Inlet connection 1" NPT h Outlet connection 1" NPT hInlet Pressure Min. 2 bar (29 psi). Max. Inlet Pressure 100 psi (6.9 bar). Output Pressure 10 - 30 psi. Flow rate at inlet pressure Max. 3.365.482 BTU/h LPG. Inlet connection 1/2" NPT h Outlet connection 1/2" NPT h.Inlet Pressure MIN. 0.7 bar (10.2 psi). MAX Inlet Pressure. 5.52 bar (80 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate at inlet pressure MIN Flow rate 27.6Kg/h LPG, at set pressure Flow rate 84.8Kg/h LPG. Inlet connection 1" NPT h Outlet connection 1" NPT h.Inlet Pressure MIN. 1 bar (14.5 psi). Inlet Pressure MAX. 4.2 bar (60.9 psi). Outlet Pressure mbar ("c.a.). Flow rate at inlet pressure inlet pressure MIN Flow rate Kg/h LPG: 0. with set pressure Flow rate Kg/h LPG: . Inlet connection 3/4" NPT h Outlet connection 3/4" NPT hInlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 5.5 bar (79.8 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate with inlet pressure MIN Flow rate 7.2Kg/h LPG, with set pressure Flow rate 10.3Kg/h LPG. Inlet connection M26 X 1,5 Outlet connection 1/2" NPT h.
Additional Information
Brand

Humcar

Connection Input

G 3/4 h SC

Connection Output

G 3/4 h JP

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

low inlet pressure shutoff and diaphragm rupture, Relief Valve

Maximum inlet pressure

87

Minimum inlet pressure

14.5

Outlet pressure

23 - 25 mbar

Nominal flow rate

6 m³/ h GN

Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Relief Valve.

Maximum inlet pressure

29

Minimum inlet pressure

3

Outlet pressure

28 mbar

Nominal flow rate

1619800 BTU/h LPG

Brand

Humcar

Connection Input

1/2" NPT h

Connection Output

1/2" NPT h

Type of Adjustment

Adjustable

Stage

First Stage

Security System

Not applicable.

Maximum inlet pressure

100 psi

Minimum inlet pressure

29 psi

Outlet pressure

10 - 30 psi

Nominal flow rate

3365482 BTU/h LPG

Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

80

Minimum inlet pressure

10.2

Outlet pressure

28 mbar

Nominal flow rate

1379500 BTU/h LPG

Brand

Humcar

Connection Input

3/4" NPT h

Connection Output

3/4" NPT h

Type of Adjustment

Adjustable

Stage

First Stage

Security System

Not applicable.

Maximum inlet pressure

60.9

Minimum inlet pressure

14.5

Outlet pressure

0.5 - 12.4 psi

Nominal flow rate

215736 BTU/h LPG

Brand

Humcar

Connection Input

5, M26 X 1

Connection Output

1/2" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

79.8

Minimum inlet pressure

20.3

Outlet pressure

28 mbar

Nominal flow rate

360450 BTU/h LPG

Cart
No products in the cart.
Notificaciones Judiciales
Email
WhatsApp
Phone
WhatsApp
Phone
Email
Notificaciones Judiciales
Select the fields to display
  • Image
  • Reference
  • Rating
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Additional Information
Click outside the comparison bar to close it.
Compare