High Pressure Regulator R150 Direct Acting First Stage LPG 10-30 psi 3/4" NPT h x 3/4" NPT h 6500000 BTU/h LPG
High Pressure Regulator R150 Direct Acting First Stage LPG 10-30 psi 3/4" NPT h x 3/4" NPT h 6500000 BTU/h LPG
External use regulator for commercial and industrial gas installations. NFPA-58 and NTC-3873 Reference Standard. With different flow rates according to the application and safety device.
External use regulator for commercial and industrial gas installations. NFPA-58 and NTC-3873 Reference Standard. With different flow rates according to the application and safety device.
Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
Regulator for internal use for residential gas installations. Reference Standard NTC-3293. With different flow rates according to the application and safety device Proportional Shut-Off and Low Pressure Cut-Off at the inlet.
Content
Inlet Pressure Min. 2 bar (29 psi). Max. inlet pressure 100 psi (6.9 bar). Output pressure range 10-30 psi . Flow rate 6.500.000 BTU/h LPG. Inlet Connection 3/4" NPT h Outlet Connection 3/4" NPT h.
Inlet pressure min. 1 bar (14.5 psi). Max. inlet pressure 6.9 bar (100 psi). Outlet Pressure 28 mbar (11.2 "c.a.). Flow rate at min. inlet pressure Flow rate 8.6Kg/h LPG (431,650 BTU/h LPG), at set pressure Flow rate 26.5Kg/h LPG (1,323,430 BTU/h LPG). Inlet connection 3/4" NPTh Inlet connection 3/4" NPTh Outlet connection.
Inlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 5.52 bar (80 psi). Outlet Pressure 350 mbar (140 "w.c.). Flow rate at inlet pressure MIN Flow rate 44.2Kg/h LPG, at set pressure Flow rate 53.3Kg/h LPG. Inlet connection 1" NPT h Outlet connection 1" NPT h.
Inlet Pressure MIN. 0.7 bar (10.2 psi). MAX Inlet Pressure. 5.52 bar (80 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate at inlet pressure MIN Flow rate 27.6Kg/h LPG, at set pressure Flow rate 84.8Kg/h LPG. Inlet connection 1" NPT h Outlet connection 1" NPT h.
Inlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 5.52 bar (80 psi). Outlet Pressure 350 mbar (140 "w.c.). Flow rate with inlet pressure MIN Flow rate 44.2Kg/h LPG, with set pressure Flow rate 53.3Kg/h LPG. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT h.
Inlet Pressure MIN. bar (1.5 psi). Inlet Pressure MAX. bar (9.9 psi). Outlet Pressure 35 mbar (14 "w.c.). Flow rate at inlet pressure
inlet pressure MIN. m³/ h GN 12. with set pressure m³/ h GN 23. Inlet connection 1/2" NPT h Outlet connection 1/2" NPT h
Additional Information
Brand
Humcar
Connection Input
3/4" NPTh
Connection Output
3/4" NPT h
Type of Adjustment
Adjustable
Stage
First Stage
Security System
Not applicable.
Maximum inlet pressure
100 psi
Minimum inlet pressure
29 psi
Outlet pressure
10 - 30 psi
Nominal flow rate
6,500,000 BTU/h LPG
Brand
Humcar
Connection Input
3/4" NPT h
Connection Output
3/4" NPT h
Type of Adjustment
Not Adjustable
Stage
Single Stage
Security System
Relief Valve.
Maximum inlet pressure
100 psi
Minimum inlet pressure
14.5 psi
Outlet pressure
28 mbar
Nominal flow rate
431650 BTU/h LPG
Brand
Humcar
Connection Input
1" NPT h
Connection Output
1" NPT h
Type of Adjustment
Not Adjustable
Stage
First Stage
Security System
Relief Valve.
Maximum inlet pressure
80
Minimum inlet pressure
20.3
Outlet pressure
350 mbar
Nominal flow rate
2207200 BTU/h LPG
Brand
Humcar
Connection Input
1" NPT h
Connection Output
1" NPT h
Type of Adjustment
Not Adjustable
Stage
Single Stage
Security System
Relief Valve.
Maximum inlet pressure
80
Minimum inlet pressure
10.2
Outlet pressure
28 mbar
Nominal flow rate
1379500 BTU/h LPG
Brand
Humcar
Connection Input
3/4" NPT h
Connection Output
3/4" NPT h
Type of Adjustment
Not Adjustable
Stage
First Stage
Security System
Relief Valve.
Maximum inlet pressure
80
Minimum inlet pressure
20.3
Outlet pressure
350 mbar
Nominal flow rate
2207200 BTU/h LPG
Brand
Humcar
Connection Input
1/2" NPT h
Connection Output
1/2" NPT h
Type of Adjustment
Not Adjustable
Stage
Second Stage
Security System
Proportional shut-off and low pressure cut-off at the inlet.
Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
Regulator for internal use for residential gas installations. Reference Standard NTC-3293. With different flow rates according to the application and safety device Proportional Shut-Off and Low Pressure Cut-Off at the inlet.
Regulator for external use for residential installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3727. With different flow rates according to the application and safety device relief valve.