Regulador H5 OUPSO Acción Directa Primera Etapa GN-GLP 340mbar 1”NPTh x 1-1/2”NPTh
H5 OUPSO Direct Acting First Stage Regulator GN-GLP 340mbar 1 "NPTh x 1-1/2 "NPTh
Regulator for external use for medium commercial installations and gas industry. Reference Standard EN334 and under the guidelines 2014/68/EU With different flow rates depending on the application and safety device Relief Valve.
Presión de Entrada mín. 1 bar (14,5 psi). Presión de Entrada máx. 6 bar (87 psi). Presión de Salida 340 mbar (136 “c.a.). Conexión Entrada 1” NPT h Conexión Salida 1- 1/2” NPT h.
Additional information
Brand
ESKA
Connection Input
1" NPT h
Connection Output
1 1/2” NPT h
Type of Adjustment
Not Adjustable
Stage
First Stage
Security System
Corte por Baja y Alta Presión a la entrada, Válvula de Alivio
Regulator for external use for medium commercial installations and gas industry. Reference Standard EN334 and under the guidelines 2014/68/EU With different flow rates depending on the application and safety device Relief Valve.
Regulator for internal use for residential gas installations. Reference Standard NTC-3293. With different flow rates according to the application and safety device Proportional Shut-Off and Low Pressure Cut-Off at the inlet.
Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
External use regulator for residential and commercial gas installations. Reference Standard MX-032-X-SCFI-2013 and specification ES.02260.MX-CN. With different flow rates according to the application and safety device relief valve and low pressure cut-off (UPSO).
Regulator for external use for residential gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device.
Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
Content
Presión de Entrada mín. 1 bar (14,5 psi). Presión de Entrada máx. 6 bar (87 psi). Presión de Salida 340 mbar (136 "c.a.). Conexión Entrada 1” NPT h Conexión Salida 1- 1/2” NPT h.
Inlet Pressure MIN. bar (1.5 psi). Inlet Pressure MAX. bar (9.9 psi). Outlet Pressure 35 mbar (14 "w.c.). Flow rate at inlet pressure
inlet pressure MIN. m³/ h GN 12. with set pressure m³/ h GN 23. Inlet connection 1/2" NPT h Outlet connection 1/2" NPT h
Inlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 5.52 bar (80 psi). Outlet Pressure 350 mbar (140 "w.c.). Flow rate with inlet pressure MIN Flow rate 44.2Kg/h LPG, with set pressure Flow rate 53.3Kg/h LPG. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT h.
Inlet Pressure MIN. 1 bar (14.5 psi). Inlet Pressure MAX. 4 bar (58 psi). Outlet Pressure 21 mbar (8.4 "w.c.). Flow rate at inlet pressure
inlet pressure MIN Flow Kg/h LPG: 0. with set pressure m³/ h GN 10. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT h
Inlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 6.9 bar (100 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate with inlet pressure MIN Flow rate 17.3Kg/h LPG. With set pressure Flow 30 Kg/h LPG. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT h
Inlet pressure min. 1 bar (14.5 psi). Max. inlet pressure 6.9 bar (100 psi). Outlet Pressure 28 mbar (11.2 "c.a.). Flow rate at min. inlet pressure Flow rate 8.6Kg/h LPG (431,650 BTU/h LPG), at set pressure Flow rate 26.5Kg/h LPG (1,323,430 BTU/h LPG). Inlet connection 3/4" NPTh Inlet connection 3/4" NPTh Outlet connection.
Additional Information
Brand
ESKA
Connection Input
1" NPT h
Connection Output
1 1/2” NPT h
Type of Adjustment
Not Adjustable
Stage
First Stage
Security System
Corte por Baja y Alta Presión a la entrada, Válvula de Alivio
Maximum inlet pressure
87 psi
Minimum inlet pressure
14.5 psi
Outlet pressure
340 mbar, AC 10
Nominal flow rate
AC 10 : 240m³/h GN – 277 Kg/h GLP
Brand
Humcar
Connection Input
1/2" NPT h
Connection Output
1/2" NPT h
Type of Adjustment
Not Adjustable
Stage
Second Stage
Security System
Proportional shut-off and low pressure cut-off at the inlet.
Regulator for external use for residential gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3727. With different flow rates according to the application and safety device relief valve.
Regulator for external use for residential and commercial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.