Regulador H5 OUPSO Acción Directa Primera Etapa GN-GLP 340mbar 1”NPTh x 1-1/2”NPTh
H5 OUPSO Direct Acting First Stage Regulator GN-GLP 340mbar 1 "NPTh x 1-1/2 "NPTh
Regulator for external use for medium commercial installations and gas industry. Reference Standard EN334 and under the guidelines 2014/68/EU With different flow rates depending on the application and safety device Relief Valve.
Presión de Entrada mín. 1 bar (14,5 psi). Presión de Entrada máx. 6 bar (87 psi). Presión de Salida 340 mbar (136 “c.a.). Conexión Entrada 1” NPT h Conexión Salida 1- 1/2” NPT h.
Additional information
Brand
ESKA
Connection Input
1" NPT h
Connection Output
1 1/2” NPT h
Type of Adjustment
Not Adjustable
Stage
First Stage
Security System
Corte por Baja y Alta Presión a la entrada, Válvula de Alivio
Regulator for external use for medium commercial installations and gas industry. Reference Standard EN334 and under the guidelines 2014/68/EU With different flow rates depending on the application and safety device Relief Valve.
Regulator for external use for residential installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
Regulator for external use for residential gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device.
Regulator for external use for residential gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
Regulator for internal use for residential gas installations. Reference Standard NTC-3293. With different flow rates according to the application and safety device Proportional Shut-Off and Low Pressure Cut-Off at the inlet.
Content
Presión de Entrada mín. 1 bar (14,5 psi). Presión de Entrada máx. 6 bar (87 psi). Presión de Salida 340 mbar (136 "c.a.). Conexión Entrada 1” NPT h Conexión Salida 1- 1/2” NPT h.
Inlet Pressure MIN. 1.04 bar (15.1 psi). MAX Inlet Pressure. 6.9 bar (100 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate with inlet pressure MIN Flow rate 15.4Kg/h LPG, with set pressure Flow rate 22.1Kg/h LPG. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT h.
Inlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 6.9 bar (100 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate with inlet pressure MIN Flow rate 17.3Kg/h LPG. With set pressure Flow 30 Kg/h LPG. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT h
Inlet Pressure MIN. 0.7 bar (10.2 psi). MAX Inlet Pressure. 7 bar (100 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate with inlet pressure MIN Flow rate 1.4Kg/h LPG, with set pressure Flow rate 2.6Kg/h LPG. Connection Inlet M11 X 1 Connection Outlet 3/8" NPT h
Inlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 5.52 bar (80 psi). Outlet Pressure 350 mbar (140 "w.c.). Flow rate at inlet pressure MIN Flow rate 44.2Kg/h LPG, at set pressure Flow rate 53.3Kg/h LPG. Inlet connection 1" NPT h Outlet connection 1" NPT h.
Inlet Pressure MIN. bar (1.5 psi). Inlet Pressure MAX. bar (9.9 psi). Outlet Pressure 35 mbar (14 "w.c.). Flow rate at inlet pressure
inlet pressure MIN. m³/ h GN 12. with set pressure m³/ h GN 23. Inlet connection 1/2" NPT h Outlet connection 1/2" NPT h
Additional Information
Brand
ESKA
Connection Input
1" NPT h
Connection Output
1 1/2” NPT h
Type of Adjustment
Not Adjustable
Stage
First Stage
Security System
Corte por Baja y Alta Presión a la entrada, Válvula de Alivio
Maximum inlet pressure
87 psi
Minimum inlet pressure
14.5 psi
Outlet pressure
340 mbar, AC 10
Nominal flow rate
AC 10 : 240m³/h GN – 277 Kg/h GLP
Brand
Humcar
Connection Input
3/4" NPT h
Connection Output
3/4" NPT h
Type of Adjustment
Not Adjustable
Stage
Single Stage
Security System
Relief Valve.
Maximum inlet pressure
100
Minimum inlet pressure
15.1
Outlet pressure
28 mbar
Nominal flow rate
768960 BTU/h LPG
Brand
Humcar
Connection Input
3/4" NPT h
Connection Output
3/4" NPT h
Type of Adjustment
Not Adjustable
Stage
Single Stage
Security System
Relief Valve.
Maximum inlet pressure
100
Minimum inlet pressure
20.3
Outlet pressure
28 mbar
Nominal flow rate
863300 BTU/h LPG
Brand
Humcar
Connection Input
M11 X 1
Connection Output
3/8" NPT h
Type of Adjustment
Not Adjustable
Stage
Single Stage
Security System
Relief Valve.
Maximum inlet pressure
100
Minimum inlet pressure
10.2
Outlet pressure
28 mbar
Nominal flow rate
72090 BTU/h LPG
Brand
Humcar
Connection Input
1" NPT h
Connection Output
1" NPT h
Type of Adjustment
Not Adjustable
Stage
First Stage
Security System
Relief Valve.
Maximum inlet pressure
80
Minimum inlet pressure
20.3
Outlet pressure
350 mbar
Nominal flow rate
2207200 BTU/h LPG
Brand
Humcar
Connection Input
1/2" NPT h
Connection Output
1/2" NPT h
Type of Adjustment
Not Adjustable
Stage
Second Stage
Security System
Proportional shut-off and low pressure cut-off at the inlet.
Regulator for external use for residential and commercial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
Regulator for external use for residential gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device.
Regulator for internal use for residential gas installations. Reference Standard NTC-3293. With different flow rates according to the application and safety device Proportional Shut-Off and Low Pressure Cut-Off at the inlet.
Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.