First stage regulator used in the handling of propane gas (LPG) for commercial and industrial networks. It has an OPSO safety device: it blocks the flow entry to the regulator without releasing gas to the atmosphere avoiding GHG (GREENHOUSE GASES). With overpressure valve connection adapted for ¼" tubing.
First stage regulator used in the handling of propane gas (LPG) for commercial and industrial networks. It has an OPSO safety device: it blocks the flow entry to the regulator without releasing gas to the atmosphere avoiding GHG (GREENHOUSE GASES). With overpressure valve connection adapted for ¼" tubing.
Regulator for external use for residential gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device.
Regulator for internal use for residential gas installations. Reference Standard NTC-3293. With different flow rates according to the application and safety device Proportional Shut-Off and Low Pressure Cut-Off at the inlet.
Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
Regulator for external use for residential and commercial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
Content
Inlet Pressure min. 1.4 bar (20 psi). Max. inlet pressure 125 psi (8.6 bar). Outlet Pressure 42 psi (2.9 bar). Inlet 1-1/4" NPT connection h Outlet 1-1/4" NPT connection h
Inlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 6.9 bar (100 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate with inlet pressure MIN Flow rate 17.3Kg/h LPG, with set pressure Flow rate 30Kg/h LPG. Inlet connection 1" NPT h Outlet connection 1" NPT h
Inlet Pressure MIN. bar (3 psi). Inlet Pressure MAX. bar (10 psi). Outlet Pressure 50 mbar (20 "c.a.). Flow rate at inlet pressure
inlet pressure MIN. m³/ h GN 20. with set pressure m³/ h GN 19. Inlet connection 1/2" NPT h Outlet connection 1/2" NPT h
Presión de Entrada MIN. 0.21 bar (3 psi). Presión de Entrada MÁX. 2 bar (29 psi). Presión de Salida 28 mbar (11.2 "c.a.). Caudal con presión
de entrada MÍN Caudal Kg/h GLP: 32.5. con presión de ajuste Caudal Kg/h GLP: 46.4285714285714. Conexión Entrada 1” NPT h Conexión Salida 1” NPT h
Inlet Pressure MIN. 0.7 bar (10.2 psi). MAX Inlet Pressure. 5.52 bar (80 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate with inlet pressure MIN 27.6Kg/h LPG, with set pressure Flow rate 84.8Kg/h LPG. Connection Inlet 1-1/4" NPT h Connection Outlet 1-1/4" NPT h.
Inlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 6.9 bar (100 psi). Outlet Pressure 15 psi (1034 mbar). Flow rate with inlet pressure MIN Flow rate 33.9 Kg/h LPG, with set pressure Flow rate 105.7 Kg/h LPG. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT h.
Additional Information
Dimensions
360 × 283 × 205 cm
Brand
Humcar
Connection Input
1 1/4" NPT h
Connection Output
1 1/4" NPTh
Type of Adjustment
Not Adjustable
Stage
First Stage
Security System
Overpressure cutting.
Maximum inlet pressure
125 psi
Minimum inlet pressure
20 psi
Outlet pressure
2.9 bar
Nominal flow rate
285.7 kg/h LPG
Brand
Humcar
Connection Input
1" NPT h
Connection Output
1" NPT h
Type of Adjustment
Not Adjustable
Stage
Single Stage
Security System
Relief Valve.
Maximum inlet pressure
100
Minimum inlet pressure
20.3
Outlet pressure
28 mbar
Nominal flow rate
863300 BTU/h LPG
Brand
Humcar
Connection Input
1/2" NPT h
Connection Output
1/2" NPT h
Type of Adjustment
Not Adjustable
Stage
Second Stage
Security System
Proportional shut-off and low pressure cut-off at the inlet.
Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
External use regulator for residential and commercial gas installations. Reference Standard MX-032-X-SCFI-2013 and specification ES.02260.MX-CN. With different flow rates according to the application and safety device relief valve and low pressure cut-off (UPSO).
Regulator for external use for residential gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
Regulator for external use for residential installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.