External use regulator for residential and industrial gas installations. Manufactured under NTC-3727 standard. With different flow rates according to the application and safety device relief valve.

Description

Presión de Entrada Mín. 1,4 bar (20,3 psi). Presión de Entrada Máx. 5,52 bar (80 psi). Presión de Salida 140 mbar (2,03 psi). Caudal con presión de entrada Mín. 40 m³/ h GN. Con presión de ajuste 49,5m³/ h GN . Conexión Entrada 1” NPT h Conexión Salida 1” NPT h.

Additional information

Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

First Stage

Security System

Relief Valve.

Maximum inlet pressure

80 psi

Minimum inlet pressure

20.3 psi

Outlet pressure

140 mbar

Max. flow rate

40 m³/h GN

Nominal flow rate

49.5 m³/h GN

Documents

Quick comparison

Regulador R10 Acción Directa Primera Etapa GN 140 mbar 1” NPT h x 1” NPT h 40 m³/ h GN RemoverRegulator R4 Direct Acting Single Stage LPG 28 mbar M26 X 1.5 x 1/2" NPT h 360450 BTU/h LPG RemoveRegulator R10 UPSO Direct Acting Single Stage GN 21 mbar 3/4" NPT h x 3/4" NPT h 10 m³/ h GN RemoveRegulator R50 Direct Acting Second Stage LPG 28 mbar 1" NPT h x 1" NPT h 1619800 BTU/h LPG RemoveRegulator R101 Direct Acting Single Stage LPG 28 mbar M11 X 1 x 3/8" NPT h 72090 BTU/h LPG RemoveRegulator R10 Direct Acting First Stage LPG 15 psi 3/4" NPT h x 3/4" NPT h 1691000 BTU/h LPG Remove
NameRegulador R10 Acción Directa Primera Etapa GN 140 mbar 1” NPT h x 1” NPT h 40 m³/ h GN RemoverRegulator R4 Direct Acting Single Stage LPG 28 mbar M26 X 1.5 x 1/2" NPT h 360450 BTU/h LPG RemoveRegulator R10 UPSO Direct Acting Single Stage GN 21 mbar 3/4" NPT h x 3/4" NPT h 10 m³/ h GN RemoveRegulator R50 Direct Acting Second Stage LPG 28 mbar 1" NPT h x 1" NPT h 1619800 BTU/h LPG RemoveRegulator R101 Direct Acting Single Stage LPG 28 mbar M11 X 1 x 3/8" NPT h 72090 BTU/h LPG RemoveRegulator R10 Direct Acting First Stage LPG 15 psi 3/4" NPT h x 3/4" NPT h 1691000 BTU/h LPG Remove
ImageRegulador R10  Acción Directa Primera Etapa GN  140 mbar 1” NPT h x 1” NPT h 40 m³/ h GNRegulator R4 Direct Acting Single Stage LPG 28 mbar M26 X 1.5 x 1/2" NPT h 360450 BTU/h LPGRegulator R10 UPSO Direct Acting Single Stage GN 21 mbar 3/4" NPT h x 3/4" NPT h 10 m³/ h GNRegulator R50 Direct Acting Second Stage LPG 28 mbar 1" NPT h x 1" NPT h 1619800 BTU/h LPGRegulator R101 Direct Acting Single Stage LPG 28 mbar M11 X 1 x 3/8" NPT h 72090 BTU/h LPGRegulator R10 Direct Acting First Stage LPG 15 psi 3/4" NPT h x 3/4" NPT h 1691000 BTU/h LPG
Reference411249410818411206414003410880411261
Rating
Stock
Availability
Add to cart

Read more

Read more

Read more

Read more

Read more

Read more

DescriptionExternal use regulator for residential and industrial gas installations. Manufactured under NTC-3727 standard. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.External use regulator for residential and commercial gas installations. Reference Standard MX-032-X-SCFI-2013 and specification ES.02260.MX-CN. With different flow rates according to the application and safety device relief valve and low pressure cut-off (UPSO).Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential and commercial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
ContentPresión de Entrada Mín. 1,4 bar (20,3 psi). Presión de Entrada Máx. 5,52 bar (80 psi). Presión de Salida 140 mbar (2,03 psi). Caudal con presión de entrada Mín. 40 m³/ h GN. Con presión de ajuste 49,5m³/ h GN . Conexión Entrada 1” NPT h Conexión Salida 1” NPT h.Inlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 5.5 bar (79.8 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate with inlet pressure MIN Flow rate 7.2Kg/h LPG, with set pressure Flow rate 10.3Kg/h LPG. Inlet connection M26 X 1,5 Outlet connection 1/2" NPT h.Inlet Pressure MIN. 1 bar (14.5 psi). Inlet Pressure MAX. 4 bar (58 psi). Outlet Pressure 21 mbar (8.4 "w.c.). Flow rate at inlet pressure inlet pressure MIN Flow Kg/h LPG: 0. with set pressure m³/ h GN 10. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT hInlet Pressure MIN. 0.21 bar (3 psi). MAX Inlet Pressure 2 bar (29 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate at inlet pressure inlet pressure MIN Flow rate Kg/h LPG: 32.5. with set pressure Flow rate Kg/h LPG: 46.4285714285714. Inlet connection 1" NPT h Outlet connection 1" NPT hInlet Pressure MIN. 0.7 bar (10.2 psi). MAX Inlet Pressure. 7 bar (100 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate with inlet pressure MIN Flow rate 1.4Kg/h LPG, with set pressure Flow rate 2.6Kg/h LPG. Connection Inlet M11 X 1 Connection Outlet 3/8" NPT hInlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 6.9 bar (100 psi). Outlet Pressure 15 psi (1034 mbar). Flow rate with inlet pressure MIN Flow rate 33.9 Kg/h LPG, with set pressure Flow rate 105.7 Kg/h LPG. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT h.
Additional Information
Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

First Stage

Security System

Relief Valve.

Maximum inlet pressure

80 psi

Minimum inlet pressure

20.3 psi

Outlet pressure

140 mbar

Max. flow rate

40 m³/h GN

Nominal flow rate

49.5 m³/h GN

Brand

Humcar

Connection Input

5, M26 X 1

Connection Output

1/2" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

79.8

Minimum inlet pressure

20.3

Outlet pressure

28 mbar

Nominal flow rate

360450 BTU/h LPG

Brand

Humcar

Connection Input

3/4" NPT h

Connection Output

3/4" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

58

Minimum inlet pressure

14.5

Outlet pressure

21 mbar

Nominal flow rate

10 m³/ h GN

Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Relief Valve.

Maximum inlet pressure

29

Minimum inlet pressure

3

Outlet pressure

28 mbar

Nominal flow rate

1619800 BTU/h LPG

Brand

Humcar

Connection Input

M11 X 1

Connection Output

3/8" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

100

Minimum inlet pressure

10.2

Outlet pressure

28 mbar

Nominal flow rate

72090 BTU/h LPG

Brand

Humcar

Connection Input

3/4" NPT h

Connection Output

3/4" NPT h

Type of Adjustment

Not Adjustable

Stage

First Stage

Security System

Relief Valve.

Maximum inlet pressure

100

Minimum inlet pressure

20.3

Outlet pressure

15 psi

Nominal flow rate

1691000 BTU/h LPG

Cart
No products in the cart.
Notificaciones Judiciales
Email
WhatsApp
Phone
WhatsApp
Phone
Email
Notificaciones Judiciales
Select the fields to display
  • Image
  • Reference
  • Rating
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Additional Information
Click outside the comparison bar to close it.
Compare