• Home
  • Products
  • Regulator R20 Direct Acting Single Stage LPG 28 mbar Handwheel 7/8 NGO x 3/8" Hose Coupling 44585 BTU/h LPG

Regulator R20 Direct Acting Single Stage LPG 28 mbar Handwheel 7/8 NGO x 3/8" Hose Coupling 44585 BTU/h LPG

External use regulator for installations with portable LPG cylinders. Reference Standard NTC-3873, NTC-332 and NTC-3561-2. With different flow rates according to the application and safety device.

Description

Inlet Pressure MIN. 0.7 bar (10.2 psi). MAX Inlet Pressure 8.6 bar (124.7 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate at inlet pressure MIN 0.89 Kg/h LPG flow rate: 0.89. Connection Inlet Handwheel 7/8 NGO Connection Outlet Coupling Hose 3/8".

Additional information

Brand

Humcar

Connection Input

Flywheel 7/8 NGO

Connection Output

3/8" Hose Coupling

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

124.7

Minimum inlet pressure

10.2

Outlet pressure

28 mbar

Nominal flow rate

44585 BTU/h LPG

Documents

Quick comparison

R20 Regulator Direct Acting Single Stage LPG 28 mbar 7/8 NGO Handwheel x 3/8" Hose Coupling 44585 BTU/h LPG RemoveRegulator R10 Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 863300 BTU/h LPG RemoveRegulator R50 Direct Acting Second Stage GN 21 mbar 1 NPT h x 1 NPT h 43 m³/ h GN RemoveRegulator R50 Direct Acting Single Stage LPG 28 mbar 1-1/4" NPT h x 1-1/4" NPT h 1379500 BTU/h LPG RemoveRegulator R102 Direct Acting Single Stage LPG 28 mbar Quick Coupling Ø35 mm x 3/8" Hose Coupling 64792 BTU/h LPG RemoveRegulator R50 Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 1379500 BTU/h LPG Remove
NameR20 Regulator Direct Acting Single Stage LPG 28 mbar 7/8 NGO Handwheel x 3/8" Hose Coupling 44585 BTU/h LPG RemoveRegulator R10 Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 863300 BTU/h LPG RemoveRegulator R50 Direct Acting Second Stage GN 21 mbar 1 NPT h x 1 NPT h 43 m³/ h GN RemoveRegulator R50 Direct Acting Single Stage LPG 28 mbar 1-1/4" NPT h x 1-1/4" NPT h 1379500 BTU/h LPG RemoveRegulator R102 Direct Acting Single Stage LPG 28 mbar Quick Coupling Ø35 mm x 3/8" Hose Coupling 64792 BTU/h LPG RemoveRegulator R50 Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 1379500 BTU/h LPG Remove
ImageRegulator R20 Direct Acting Single Stage LPG 28 mbar Handwheel 7/8 NGO x 3/8" Hose Coupling 44585 BTU/h LPGRegulator R10 Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 863300 BTU/h LPGRegulator R50 Direct Acting Second Stage GN 21 mbar 1 NPT h x 1 NPT h 43 m³/ h GNRegulator R50 Direct Acting Single Stage LPG 28 mbar 1-1/4" NPT h x 1-1/4" NPT h 1379500 BTU/h LPGRegulator R102 Direct Acting Single Stage LPG 28 mbar Quick Coupling Ø35 mm x 3/8" Hose Coupling 64792 BTU/h LPGRegulator R50 Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 1379500 BTU/h LPG
Reference413001411268414054414002610068414001
Rating
Stock
Availability
Add to cart

Read more

Read more

Read more

Read more

Read more

Read more

DescriptionExternal use regulator for installations with portable LPG cylinders. Reference Standard NTC-3873, NTC-332 and NTC-3561-2. With different flow rates according to the application and safety device.Regulator for external use for residential gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3727. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for installations with portable LPG cylinders. Reference Standard NTC-3873 With different flow rates according to the application and safety device. Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
ContentInlet Pressure MIN. 0.7 bar (10.2 psi). MAX Inlet Pressure 8.6 bar (124.7 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate at inlet pressure MIN 0.89 Kg/h LPG flow rate: 0.89. Connection Inlet Handwheel 7/8 NGO Connection Outlet Coupling Hose 3/8".Inlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 6.9 bar (100 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate with inlet pressure MIN Flow rate 17.3Kg/h LPG, with set pressure Flow rate 30Kg/h LPG. Inlet connection 1" NPT h Outlet connection 1" NPT hInlet Pressure MIN. 0.14 bar (2 psi). MAX Inlet Pressure 0.35 bar (5 psi). Outlet Pressure 21 mbar (8.4 "w.c.). Flow rate at inlet pressure inlet pressure MIN Flow rate Kg/h LPG: 0. with set pressure m³/ h GN 43. Inlet connection 1 NPT h Outlet connection 1 NPT hInlet Pressure MIN. 0.7 bar (10.2 psi). MAX Inlet Pressure. 5.52 bar (80 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate with inlet pressure MIN 27.6Kg/h LPG, with set pressure Flow rate 84.8Kg/h LPG. Connection Inlet 1-1/4" NPT h Connection Outlet 1-1/4" NPT h.Inlet Pressure MIN. 0.7 bar (10.2 psi). MAX Inlet Pressure. 7.5 bar (108.8 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate at inlet pressure inlet pressure MIN Flow rate Kg/h LPG: 1.3. with set pressure Flow rate Kg/h LPG: . Inlet connection Quick coupling Ø35 mm Outlet connection Hose coupling 3/8".Inlet Pressure MIN. 0.7 bar (10.2 psi). MAX Inlet Pressure. 5.52 bar (80 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate at inlet pressure MIN Flow rate 27.6Kg/h LPG, at set pressure Flow rate 84.8Kg/h LPG. Inlet connection 1" NPT h Outlet connection 1" NPT h.
Additional Information
Brand

Humcar

Connection Input

Flywheel 7/8 NGO

Connection Output

3/8" Hose Coupling

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

124.7

Minimum inlet pressure

10.2

Outlet pressure

28 mbar

Nominal flow rate

44585 BTU/h LPG

Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

100

Minimum inlet pressure

20.3

Outlet pressure

28 mbar

Nominal flow rate

863300 BTU/h LPG

Brand

Humcar

Connection Input

1 NPT h

Connection Output

1 NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Relief Valve.

Maximum inlet pressure

5

Minimum inlet pressure

2

Outlet pressure

21 mbar

Nominal flow rate

43 m³/ h GN

Brand

Humcar

Connection Input

1-1/4" NPT h

Connection Output

1-1/4" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

80

Minimum inlet pressure

10.2

Outlet pressure

28 mbar

Nominal flow rate

1379500 BTU/h LPG

Brand

By Humcar

Connection Input

Quick Coupling Ø35 mm

Connection Output

3/8" Hose Coupling

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Not applicable.

Maximum inlet pressure

108.8

Minimum inlet pressure

10.2

Outlet pressure

28 mbar

Nominal flow rate

64792 BTU/h LPG

Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

80

Minimum inlet pressure

10.2

Outlet pressure

28 mbar

Nominal flow rate

1379500 BTU/h LPG

Cart
No products in the cart.
Notificaciones Judiciales
Email
WhatsApp
Phone
WhatsApp
Phone
Email
Notificaciones Judiciales
Select the fields to display
  • Image
  • Reference
  • Rating
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Additional Information
Click outside the comparison bar to close it.
Compare