• Home
  • Products
  • Regulator R7 UPSO 90° Direct Action Single Stage LPG 35 mbar G 3/4 h SC x G 3/4 h JP 273984 BTU/h LPG

Regulator R7 UPSO 90° Direct Acting Single Stage LPG 35 mbar G 3/4 h SC x G 3/4 h JP 273984 BTU/h LPG

Regulator for external use for residential gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device, relief valve, low pressure cut-off at the inlet and diaphragm rupture.

Description

Inlet Pressure MIN. 0.6 bar (8.7 psi). MAX Inlet Pressure 2 bar (29 psi). Outlet Pressure 35 mbar (14 "a.c.). Flow rate at inlet pressure MIN Flow rate 5.5Kg/h LPG. Connection Inlet G 3/4 h SC Connection Outlet G 3/4 h JP

Additional information

Brand

Humcar

Connection Input

G 3/4 h SC

Connection Output

G 3/4 h JP

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

low inlet pressure shutoff and diaphragm rupture, Relief Valve

Maximum inlet pressure

29

Minimum inlet pressure

8.7

Outlet pressure

35 mbar

Nominal flow rate

273984 BTU/h LPG

Documents

Quick comparison

Regulator R7 UPSO 90° Direct Acting Single Stage LPG 35 mbar G 3/4 h SC x G 3/4 h JP 273984 BTU/h LPG RemoveRegulator R10 Direct Acting First Stage LPG 350 mbar 3/4" NPT h x 3/4" NPT h 2207200 BTU/h LPG RemoveRegulator R10 Direct Acting First Stage LPG 140 mbar 1" NPT h x 1" NPT h 2207200 BTU/h LPG RemoveRegulator R50 Direct Acting Second Stage GN 21 mbar 1 NPT h x 1 NPT h 43 m³/ h GN RemoveRegulator R101 Direct Acting Single Stage LPG 28 mbar M11 X 1 x 3/8" NPT h 72090 BTU/h LPG RemoveRegulator R10 Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 863300 BTU/h LPG Remove
NameRegulator R7 UPSO 90° Direct Acting Single Stage LPG 35 mbar G 3/4 h SC x G 3/4 h JP 273984 BTU/h LPG RemoveRegulator R10 Direct Acting First Stage LPG 350 mbar 3/4" NPT h x 3/4" NPT h 2207200 BTU/h LPG RemoveRegulator R10 Direct Acting First Stage LPG 140 mbar 1" NPT h x 1" NPT h 2207200 BTU/h LPG RemoveRegulator R50 Direct Acting Second Stage GN 21 mbar 1 NPT h x 1 NPT h 43 m³/ h GN RemoveRegulator R101 Direct Acting Single Stage LPG 28 mbar M11 X 1 x 3/8" NPT h 72090 BTU/h LPG RemoveRegulator R10 Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 863300 BTU/h LPG Remove
ImageRegulator R7 UPSO 90° Direct Acting Single Stage LPG 35 mbar G 3/4 h SC x G 3/4 h JP 273984 BTU/h LPGRegulator R10 Direct Acting LPG First Stage 350 mbar 3/4" NPT h x 3/4" NPT h 2207200 BTU/h LPGRegulator R10 Direct Acting First Stage LPG 140 mbar 1" NPT h x 1" NPT h 2207200 BTU/h LPGRegulator R50 Direct Acting Second Stage GN 21 mbar 1 NPT h x 1 NPT h 43 m³/ h GNRegulator R101 Direct Acting Single Stage LPG 28 mbar M11 X 1 x 3/8" NPT h 72090 BTU/h LPGRegulator R10 Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 863300 BTU/h LPG
Reference411027411257411260414054410880411268
Rating
Stock
Availability
Add to cart

Read more

Read more

Read more

Read more

Read more

Read more

DescriptionRegulator for external use for residential gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device, relief valve, low pressure cut-off at the inlet and diaphragm rupture.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3727. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device.
ContentInlet Pressure MIN. 0.6 bar (8.7 psi). MAX Inlet Pressure 2 bar (29 psi). Outlet Pressure 35 mbar (14 "a.c.). Flow rate at inlet pressure MIN Flow rate 5.5Kg/h LPG. Connection Inlet G 3/4 h SC Connection Outlet G 3/4 h JPInlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 5.52 bar (80 psi). Outlet Pressure 350 mbar (140 "w.c.). Flow rate with inlet pressure MIN Flow rate 44.2Kg/h LPG, with set pressure Flow rate 53.3Kg/h LPG. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT h.Inlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 5.52 bar (80 psi). Outlet Pressure 140 mbar (56 "w.c.). Flow rate at inlet pressure MIN Flow rate 44.2Kg/h LPG, at set pressure Flow rate 54.4Kg/h LPG. Inlet connection 1" NPT h Outlet connection 1" NPT h.Inlet Pressure MIN. 0.14 bar (2 psi). MAX Inlet Pressure 0.35 bar (5 psi). Outlet Pressure 21 mbar (8.4 "w.c.). Flow rate at inlet pressure inlet pressure MIN Flow rate Kg/h LPG: 0. with set pressure m³/ h GN 43. Inlet connection 1 NPT h Outlet connection 1 NPT hInlet Pressure MIN. 0.7 bar (10.2 psi). MAX Inlet Pressure. 7 bar (100 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate with inlet pressure MIN Flow rate 1.4Kg/h LPG, with set pressure Flow rate 2.6Kg/h LPG. Connection Inlet M11 X 1 Connection Outlet 3/8" NPT hInlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 6.9 bar (100 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate with inlet pressure MIN Flow rate 17.3Kg/h LPG, with set pressure Flow rate 30Kg/h LPG. Inlet connection 1" NPT h Outlet connection 1" NPT h
Additional Information
Brand

Humcar

Connection Input

G 3/4 h SC

Connection Output

G 3/4 h JP

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

low inlet pressure shutoff and diaphragm rupture, Relief Valve

Maximum inlet pressure

29

Minimum inlet pressure

8.7

Outlet pressure

35 mbar

Nominal flow rate

273984 BTU/h LPG

Brand

Humcar

Connection Input

3/4" NPT h

Connection Output

3/4" NPT h

Type of Adjustment

Not Adjustable

Stage

First Stage

Security System

Relief Valve.

Maximum inlet pressure

80

Minimum inlet pressure

20.3

Outlet pressure

350 mbar

Nominal flow rate

2207200 BTU/h LPG

Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

First Stage

Security System

Relief Valve.

Maximum inlet pressure

80

Minimum inlet pressure

20.3

Outlet pressure

140 mbar

Nominal flow rate

2207200 BTU/h LPG

Brand

Humcar

Connection Input

1 NPT h

Connection Output

1 NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Relief Valve.

Maximum inlet pressure

5

Minimum inlet pressure

2

Outlet pressure

21 mbar

Nominal flow rate

43 m³/ h GN

Brand

Humcar

Connection Input

M11 X 1

Connection Output

3/8" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

100

Minimum inlet pressure

10.2

Outlet pressure

28 mbar

Nominal flow rate

72090 BTU/h LPG

Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

100

Minimum inlet pressure

20.3

Outlet pressure

28 mbar

Nominal flow rate

863300 BTU/h LPG

Cart
No products in the cart.
Notificaciones Judiciales
Email
WhatsApp
Phone
WhatsApp
Phone
Email
Notificaciones Judiciales
Select the fields to display
  • Image
  • Reference
  • Rating
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Additional Information
Click outside the comparison bar to close it.
Compare