• Home
  • Products
  • Regulador R7 UPSO 90° Acción Directa Única Etapa GN 23 mbar G 3/4 h SC x G 3/4 h JP 6 m³/ h GN

Regulator R7 UPSO 90° Direct Acting Single Stage GN 23 mbar G 3/4 h SC x G 3/4 h JP 6 m³/ h GN

Regulator for external use for residential gas installations. Reference Standard NTC-3727. With different flow rates according to the application and safety device, relief valve, low pressure cut-off at the inlet, excess flow at the outlet and diaphragm rupture.

Description

Presión de Entrada MIN. 0.7 bar (10.15 psi). Presión de Entrada MÁX. 5 bar (72.5 psi). Presión de Salida 23 mbar (9.2 “c.a.). Caudal con presión
de entrada MÍN m³/ h GN 6. con presión de ajuste m³/ h GN 8. Conexión Entrada G 3/4 h SC Conexión Salida G 3/4 h JP

Additional information

Brand

Humcar

Connection Input

G 3/4 h SC

Connection Output

G 3/4 h JP

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

low inlet pressure shut-off, excess flow at the outlet and diaphragm rupture, Relief Valve

Maximum inlet pressure

72.5

Minimum inlet pressure

10.15

Outlet pressure

23 mbar

Nominal flow rate

6 m³/ h GN

Documents

Quick comparison

Regulador R7 UPSO 90° Acción Directa Única Etapa GN 23 mbar G 3/4 h SC x G 3/4 h JP 6 m³/ h GN RemoverRegulator R10 Direct Acting First Stage LPG 15 psi 1" NPT h x 1" NPT h 1691000 BTU/h LPG RemoveRegulator R10 Direct Acting First Stage LPG 350 mbar 1" NPT h x 1" NPT h 2207200 BTU/h LPG RemoveRegulator R10 RVI Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 768960 BTU/h LPG RemoveR7 Regulator Direct Acting Single Stage LPG 28mbar 3/4 "NPTh x 3/4 "NPTh 431650BTU/h LPG RemoveRegulator R10 Direct Acting First Stage LPG 140 mbar 3/4" NPT h x 3/4" NPT h 2207200 BTU/h LPG Remove
NameRegulador R7 UPSO 90° Acción Directa Única Etapa GN 23 mbar G 3/4 h SC x G 3/4 h JP 6 m³/ h GN RemoverRegulator R10 Direct Acting First Stage LPG 15 psi 1" NPT h x 1" NPT h 1691000 BTU/h LPG RemoveRegulator R10 Direct Acting First Stage LPG 350 mbar 1" NPT h x 1" NPT h 2207200 BTU/h LPG RemoveRegulator R10 RVI Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 768960 BTU/h LPG RemoveR7 Regulator Direct Acting Single Stage LPG 28mbar 3/4 "NPTh x 3/4 "NPTh 431650BTU/h LPG RemoveRegulator R10 Direct Acting First Stage LPG 140 mbar 3/4" NPT h x 3/4" NPT h 2207200 BTU/h LPG Remove
ImageRegulator R7 UPSO 90° Direct Acting Single Stage GN 23 mbar G 3/4 h SC x G 3/4 h JP 6 m³/ h GNRegulator R10 Direct Acting First Stage LPG 15 psi 1" NPT h x 1" NPT h 1691000 BTU/h LPGRegulator R10 Direct Acting First Stage LPG 350 mbar 1" NPT h x 1" NPT h 2207200 BTU/h LPGRegulator R10 RVI Direct Acting Single Stage LPG 28 mbar 1" NPT h x 1" NPT h 768960 BTU/h LPGR7 Regulator Direct Acting Single Stage LPG 28mbar 3/4 "NPTh x 3/4 "NPTh 431650BTU/h LPGRegulator R10 Direct Acting First Stage LPG 140 mbar 3/4" NPT h x 3/4" NPT h 2207200 BTU/h LPG
Reference411051411262411258411245411022411259
Rating
Stock
Availability
Add to cart

Read more

Read more

Read more

Read more

Read more

Read more

DescriptionRegulator for external use for residential gas installations. Reference Standard NTC-3727. With different flow rates according to the application and safety device, relief valve, low pressure cut-off at the inlet, excess flow at the outlet and diaphragm rupture.Regulator for external use for residential and commercial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.
ContentPresión de Entrada MIN. 0.7 bar (10.15 psi). Presión de Entrada MÁX. 5 bar (72.5 psi). Presión de Salida 23 mbar (9.2 "c.a.). Caudal con presión de entrada MÍN m³/ h GN 6. con presión de ajuste m³/ h GN 8. Conexión Entrada G 3/4 h SC Conexión Salida G 3/4 h JP Inlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 6.9 bar (100 psi). Outlet Pressure mbar 15 psi (1034 mbar). Flow rate at inlet pressure MIN Flow rate 33.9Kg/h LPG, at set pressure Flow rate 105.7Kg/h LPG . Inlet connection 1" NPT h Outlet connection 1" NPT h.Inlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 5.52 bar (80 psi). Outlet Pressure 350 mbar (140 "w.c.). Flow rate at inlet pressure MIN Flow rate 44.2Kg/h LPG, at set pressure Flow rate 53.3Kg/h LPG. Inlet connection 1" NPT h Outlet connection 1" NPT h.Inlet Pressure MIN. 1.04 bar (15.1 psi). MAX Inlet Pressure. 6.9 bar (100 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate at inlet pressure MIN Flow rate 15.4Kg/h LPG, at set pressure Flow rate 22.1Kg/h LPG. Connection Inlet 1" NPT h Connection Outlet 1" NPT hInlet pressure min. 1 bar (14.5 psi). Max. inlet pressure 6.9 bar (100 psi). Outlet Pressure 28 mbar (11.2 "c.a.). Flow rate at min. inlet pressure Flow rate 8.6Kg/h LPG (431,650 BTU/h LPG), at set pressure Flow rate 26.5Kg/h LPG (1,323,430 BTU/h LPG). Inlet connection 3/4" NPTh Inlet connection 3/4" NPTh Outlet connection.Inlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 5.52 bar (80 psi). Outlet Pressure 140 mbar (56 "w.c.). Flow rate with inlet pressure MIN Flow rate Kg/h 44.2GLP, with set pressure Flow rate 54.4Kg/h GLP. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT h
Additional Information
Brand

Humcar

Connection Input

G 3/4 h SC

Connection Output

G 3/4 h JP

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

low inlet pressure shut-off, excess flow at the outlet and diaphragm rupture, Relief Valve

Maximum inlet pressure

72.5

Minimum inlet pressure

10.15

Outlet pressure

23 mbar

Nominal flow rate

6 m³/ h GN

Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

First Stage

Security System

Relief Valve.

Maximum inlet pressure

100

Minimum inlet pressure

20.3

Outlet pressure

15 psi

Nominal flow rate

1691000 BTU/h LPG

Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

First Stage

Security System

Relief Valve.

Maximum inlet pressure

80

Minimum inlet pressure

20.3

Outlet pressure

350 mbar

Nominal flow rate

2207200 BTU/h LPG

Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

100

Minimum inlet pressure

15.1

Outlet pressure

28 mbar

Nominal flow rate

768960 BTU/h LPG

Brand

Humcar

Connection Input

3/4" NPT h

Connection Output

3/4" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

100 psi

Minimum inlet pressure

14.5 psi

Outlet pressure

28 mbar

Nominal flow rate

431650 BTU/h LPG

Brand

Humcar

Connection Input

3/4" NPT h

Connection Output

3/4" NPT h

Type of Adjustment

Not Adjustable

Stage

First Stage

Security System

Relief Valve.

Maximum inlet pressure

80

Minimum inlet pressure

20.3

Outlet pressure

140 mbar

Nominal flow rate

2207200 BTU/h LPG

Cart
No products in the cart.
Notificaciones Judiciales
Email
WhatsApp
Phone
WhatsApp
Phone
Email
Notificaciones Judiciales
Select the fields to display
  • Image
  • Reference
  • Rating
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Additional Information
Click outside the comparison bar to close it.
Compare