Regulator for external use for residential gas installations. Reference Standard EN 88-2:2008. With different flow rates according to the application and safety device relief valve, low pressure cut-off at the inlet, excess flow at the outlet and diaphragm rupture.

Description

Presión de Entrada MIN. 0.7 bar (10.15 psi). Presión de Entrada MÁX. 5 bar (72.5 psi). Presión de Salida 23 mbar (9.2 “c.a.). Caudal con presión
de entrada MÍN m³/ h GN 6. con presión de ajuste m³/ h GN 8. Conexión Entrada G 3/4 h SC Conexión Salida G 3/4 h JP

Additional information

Brand

Humcar

Connection Input

G 3/4 h SC

Connection Output

G 3/4 h JP

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

low inlet pressure shut-off, excess flow at the outlet and diaphragm rupture, Relief Valve

Maximum inlet pressure

72.5

Minimum inlet pressure

10.15

Outlet pressure

23 mbar

Nominal flow rate

6 m³/ h GN

Documents

Quick comparison

Regulador R7 UPSO 90° Acción Directa Única Etapa GN 23 mbar G 3/4 h SC x G 3/4 h JP 6 m³/ h GN RemoverRegulator R10 RVI Direct Acting Single Stage LPG 28 mbar 3/4" NPT h x 3/4" NPT h 768960 BTU/h LPG RemoveRegulator R10 Direct Acting First Stage LPG 350 mbar 1" NPT h x 1" NPT h 2207200 BTU/h LPG RemoveRegulator R50 Direct Acting Second Stage GN 21 mbar 1 NPT h x 1 NPT h 43 m³/ h GN RemoveHigh Pressure Regulator Direct Acting First Stage LPG 10 - 30 psi 1/2" NPT h x 1/2" NPT h 3365482 BTU/h LPG RemoveLow Pressure Cut-Off Regulator RCBP Self-Compensating Second Stage GN 50 mbar 1/2" NPT h x 1/2" NPT h 20 m³/ h GN Remove
NameRegulador R7 UPSO 90° Acción Directa Única Etapa GN 23 mbar G 3/4 h SC x G 3/4 h JP 6 m³/ h GN RemoverRegulator R10 RVI Direct Acting Single Stage LPG 28 mbar 3/4" NPT h x 3/4" NPT h 768960 BTU/h LPG RemoveRegulator R10 Direct Acting First Stage LPG 350 mbar 1" NPT h x 1" NPT h 2207200 BTU/h LPG RemoveRegulator R50 Direct Acting Second Stage GN 21 mbar 1 NPT h x 1 NPT h 43 m³/ h GN RemoveHigh Pressure Regulator Direct Acting First Stage LPG 10 - 30 psi 1/2" NPT h x 1/2" NPT h 3365482 BTU/h LPG RemoveLow Pressure Cut-Off Regulator RCBP Self-Compensating Second Stage GN 50 mbar 1/2" NPT h x 1/2" NPT h 20 m³/ h GN Remove
ImageRegulator R7 UPSO 90° Direct Acting Single Stage GN 23 mbar G 3/4 h SC x G 3/4 h JP 6 m³/ h GNRegulator R10 RVI Direct Acting Single Stage LPG 28 mbar 3/4" NPT h x 3/4" NPT h 768960 BTU/h LPGRegulator R10 Direct Acting First Stage LPG 350 mbar 1" NPT h x 1" NPT h 2207200 BTU/h LPGRegulator R50 Direct Acting Second Stage GN 21 mbar 1 NPT h x 1 NPT h 43 m³/ h GNHigh Pressure Regulator Direct Acting First Stage LPG 10 - 30 psi 1/2" NPT h x 1/2" NPT h 3365482 BTU/h LPGLow Pressure Cut-Off Regulator RCBP Self-Compensating Second Stage GN 50 mbar 1/2" NPT h x 1/2" NPT h 20 m³/ h GN
Reference411034411243411258414054410200411518
Rating
Stock
Availability
Add to cart

Read more

Read more

Read more

Read more

Read more

Read more

DescriptionRegulator for external use for residential gas installations. Reference Standard EN 88-2:2008. With different flow rates according to the application and safety device relief valve, low pressure cut-off at the inlet, excess flow at the outlet and diaphragm rupture.Regulator for external use for residential installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3873. With different flow rates according to the application and safety device relief valve.Regulator for external use for residential and industrial gas installations. Reference Standard NTC-3727. With different flow rates according to the application and safety device relief valve.External use regulator for commercial and industrial gas installations. Reference Standard NFPA-58 and NTC-3873. With different flow rates according to the application and safety device.Regulator for internal use for residential gas installations. Reference Standard NTC-3293. With different flow rates according to the application and safety device Proportional Shut-Off and Low Pressure Cut-Off at the inlet.
ContentPresión de Entrada MIN. 0.7 bar (10.15 psi). Presión de Entrada MÁX. 5 bar (72.5 psi). Presión de Salida 23 mbar (9.2 "c.a.). Caudal con presión de entrada MÍN m³/ h GN 6. con presión de ajuste m³/ h GN 8. Conexión Entrada G 3/4 h SC Conexión Salida G 3/4 h JP Inlet Pressure MIN. 1.04 bar (15.1 psi). MAX Inlet Pressure. 6.9 bar (100 psi). Outlet Pressure 28 mbar (11.2 "w.c.). Flow rate with inlet pressure MIN Flow rate 15.4Kg/h LPG, with set pressure Flow rate 22.1Kg/h LPG. Inlet connection 3/4" NPT h Outlet connection 3/4" NPT h.Inlet Pressure MIN. 1.4 bar (20.3 psi). Inlet Pressure MAX. 5.52 bar (80 psi). Outlet Pressure 350 mbar (140 "w.c.). Flow rate at inlet pressure MIN Flow rate 44.2Kg/h LPG, at set pressure Flow rate 53.3Kg/h LPG. Inlet connection 1" NPT h Outlet connection 1" NPT h.Inlet Pressure MIN. 0.14 bar (2 psi). MAX Inlet Pressure 0.35 bar (5 psi). Outlet Pressure 21 mbar (8.4 "w.c.). Flow rate at inlet pressure inlet pressure MIN Flow rate Kg/h LPG: 0. with set pressure m³/ h GN 43. Inlet connection 1 NPT h Outlet connection 1 NPT hInlet Pressure Min. 2 bar (29 psi). Max. Inlet Pressure 100 psi (6.9 bar). Output Pressure 10 - 30 psi. Flow rate at inlet pressure Max. 3.365.482 BTU/h LPG. Inlet connection 1/2" NPT h Outlet connection 1/2" NPT h.Inlet Pressure MIN. bar (3 psi). Inlet Pressure MAX. bar (10 psi). Outlet Pressure 50 mbar (20 "c.a.). Flow rate at inlet pressure inlet pressure MIN. m³/ h GN 20. with set pressure m³/ h GN 19. Inlet connection 1/2" NPT h Outlet connection 1/2" NPT h
Additional Information
Brand

Humcar

Connection Input

G 3/4 h SC

Connection Output

G 3/4 h JP

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

low inlet pressure shut-off, excess flow at the outlet and diaphragm rupture, Relief Valve

Maximum inlet pressure

72.5

Minimum inlet pressure

10.15

Outlet pressure

23 mbar

Nominal flow rate

6 m³/ h GN

Brand

Humcar

Connection Input

3/4" NPT h

Connection Output

3/4" NPT h

Type of Adjustment

Not Adjustable

Stage

Single Stage

Security System

Relief Valve.

Maximum inlet pressure

100

Minimum inlet pressure

15.1

Outlet pressure

28 mbar

Nominal flow rate

768960 BTU/h LPG

Brand

Humcar

Connection Input

1" NPT h

Connection Output

1" NPT h

Type of Adjustment

Not Adjustable

Stage

First Stage

Security System

Relief Valve.

Maximum inlet pressure

80

Minimum inlet pressure

20.3

Outlet pressure

350 mbar

Nominal flow rate

2207200 BTU/h LPG

Brand

Humcar

Connection Input

1 NPT h

Connection Output

1 NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Relief Valve.

Maximum inlet pressure

5

Minimum inlet pressure

2

Outlet pressure

21 mbar

Nominal flow rate

43 m³/ h GN

Brand

Humcar

Connection Input

1/2" NPT h

Connection Output

1/2" NPT h

Type of Adjustment

Adjustable

Stage

First Stage

Security System

Not applicable.

Maximum inlet pressure

100 psi

Minimum inlet pressure

29 psi

Outlet pressure

10 - 30 psi

Nominal flow rate

3365482 BTU/h LPG

Brand

Humcar

Connection Input

1/2" NPT h

Connection Output

1/2" NPT h

Type of Adjustment

Not Adjustable

Stage

Second Stage

Security System

Proportional shut-off and low pressure cut-off at the inlet.

Maximum inlet pressure

10

Minimum inlet pressure

3

Outlet pressure

50 mbar

Nominal flow rate

20 m³/ h GN

Cart
No products in the cart.
Notificaciones Judiciales
Email
WhatsApp
Phone
WhatsApp
Phone
Email
Notificaciones Judiciales
Select the fields to display
  • Image
  • Reference
  • Rating
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Additional Information
Click outside the comparison bar to close it.
Compare